基于智能手表的生物阻抗分析用于身体成分估计:精度和与四室模型的一致性。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-02-01 DOI:10.1139/apnm-2022-0301
Caleb F Brandner, Grant M Tinsley, Austin J Graybeal
{"title":"基于智能手表的生物阻抗分析用于身体成分估计:精度和与四室模型的一致性。","authors":"Caleb F Brandner,&nbsp;Grant M Tinsley,&nbsp;Austin J Graybeal","doi":"10.1139/apnm-2022-0301","DOIUrl":null,"url":null,"abstract":"<p><p>Given that the prevalence of smartwatches has allowed them to become a hallmark in health monitoring, they are primed to provide accessible body composition estimations. The purpose of this study was to evaluate the precision and agreement of smartwatch-based bioimpedance analysis (SW-BIA) and multifrequency bioimpedance analysis (MFBIA) against a 4-compartment (4C) model criterion. A total of 186 participants (114 females) underwent body composition assessments necessary for a 4C model and SW-BIA and MFBIA. Values of total body water (TBW) from each device were compared with those obtained from bioimpedance spectroscopy. Precision was adequate though slightly lower for the smartwatch compared with other methods. No device demonstrated equivalence with the 4C model. Specifically, the SW-BIA overestimated and MFBIA underestimated body fat. MFBIA, but not SW-BIA, demonstrated equivalence for TBW. Overall error was higher for males using the smartwatch compared with females. While these findings do not invalidate the use of smartwatch-based estimates, clinicians should consider that there may be large errors relative to clinical measures. If this wearable device is intended to be used to monitor body composition change over time, these findings demonstrate the need for future research to evaluate its accuracy during follow-up testing.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Smartwatch-based bioimpedance analysis for body composition estimation: precision and agreement with a 4-compartment model.\",\"authors\":\"Caleb F Brandner,&nbsp;Grant M Tinsley,&nbsp;Austin J Graybeal\",\"doi\":\"10.1139/apnm-2022-0301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Given that the prevalence of smartwatches has allowed them to become a hallmark in health monitoring, they are primed to provide accessible body composition estimations. The purpose of this study was to evaluate the precision and agreement of smartwatch-based bioimpedance analysis (SW-BIA) and multifrequency bioimpedance analysis (MFBIA) against a 4-compartment (4C) model criterion. A total of 186 participants (114 females) underwent body composition assessments necessary for a 4C model and SW-BIA and MFBIA. Values of total body water (TBW) from each device were compared with those obtained from bioimpedance spectroscopy. Precision was adequate though slightly lower for the smartwatch compared with other methods. No device demonstrated equivalence with the 4C model. Specifically, the SW-BIA overestimated and MFBIA underestimated body fat. MFBIA, but not SW-BIA, demonstrated equivalence for TBW. Overall error was higher for males using the smartwatch compared with females. While these findings do not invalidate the use of smartwatch-based estimates, clinicians should consider that there may be large errors relative to clinical measures. If this wearable device is intended to be used to monitor body composition change over time, these findings demonstrate the need for future research to evaluate its accuracy during follow-up testing.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1139/apnm-2022-0301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1139/apnm-2022-0301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

鉴于智能手表的普及已使其成为健康监测的标志,它们已准备好提供易于获取的身体成分估计。本研究的目的是根据4室(4C)模型标准评估基于智能手表的生物阻抗分析(SW-BIA)和多频生物阻抗分析(MFBIA)的准确性和一致性。共有186名参与者(114名女性)接受了4C模型和SW-BIA和MFBIA所需的身体成分评估。用生物阻抗谱法测定各装置的总水(TBW)。与其他方法相比,智能手表的精度略低,但仍然足够。没有设备证明与4C模型等效。具体来说,SW-BIA高估了体脂,而MFBIA低估了体脂。MFBIA,而不是SW-BIA,证明了TBW的等效性。与女性相比,男性使用智能手表的总体误差更高。虽然这些发现并没有使使用基于智能手表的估计无效,但临床医生应该考虑到相对于临床测量可能存在较大的误差。如果这种可穿戴设备是用来监测身体成分随时间的变化,这些发现表明,需要进一步的研究来评估其在后续测试中的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Smartwatch-based bioimpedance analysis for body composition estimation: precision and agreement with a 4-compartment model.

Given that the prevalence of smartwatches has allowed them to become a hallmark in health monitoring, they are primed to provide accessible body composition estimations. The purpose of this study was to evaluate the precision and agreement of smartwatch-based bioimpedance analysis (SW-BIA) and multifrequency bioimpedance analysis (MFBIA) against a 4-compartment (4C) model criterion. A total of 186 participants (114 females) underwent body composition assessments necessary for a 4C model and SW-BIA and MFBIA. Values of total body water (TBW) from each device were compared with those obtained from bioimpedance spectroscopy. Precision was adequate though slightly lower for the smartwatch compared with other methods. No device demonstrated equivalence with the 4C model. Specifically, the SW-BIA overestimated and MFBIA underestimated body fat. MFBIA, but not SW-BIA, demonstrated equivalence for TBW. Overall error was higher for males using the smartwatch compared with females. While these findings do not invalidate the use of smartwatch-based estimates, clinicians should consider that there may be large errors relative to clinical measures. If this wearable device is intended to be used to monitor body composition change over time, these findings demonstrate the need for future research to evaluate its accuracy during follow-up testing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1