{"title":"毛细管区带电泳-安培检测法测定人尿中的柔红霉素","authors":"Qin Hu, Lan Zhang, Tianshu Zhou, Yuzhi Fang","doi":"10.1016/S0003-2670(00)00856-4","DOIUrl":null,"url":null,"abstract":"<div><div><span><span>A simple, reliable and reproducible method, based on capillary zone electrophoresis<span><span> with amperometric detection, for the determination of </span>daunorubicin in human urine is described in this paper. A carbon </span></span>disk electrode<span> used as working electrode. The optimal conditions of separation and detection were pH 7.8 phosphate buffer (0.15</span></span> <!-->mol/l), 8<!--> <!-->kV for the separation voltage and 0.95<!--> <!-->V (versus Ag/AgCl, 3<!--> <!-->mol/l KCl) for the detection potential. The linear range was from 2×10<sup>−6</sup> to 2×10<sup>−4</sup> <span>mol/l with the regression coefficient<span> of 0.9995, and the detection limit was 8×10</span></span><sup>−7</sup> <!-->mol/l. The method built in this paper was directly applied to the determination of daunorubicin in the imitation human urine without any other sample pre-treatment except filtration, and the assay result was satisfactory.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"416 1","pages":"Pages 15-19"},"PeriodicalIF":6.0000,"publicationDate":"2000-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of daunorubicin in human urine by capillary zone electrophoresis with amperometric detection\",\"authors\":\"Qin Hu, Lan Zhang, Tianshu Zhou, Yuzhi Fang\",\"doi\":\"10.1016/S0003-2670(00)00856-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div><span><span>A simple, reliable and reproducible method, based on capillary zone electrophoresis<span><span> with amperometric detection, for the determination of </span>daunorubicin in human urine is described in this paper. A carbon </span></span>disk electrode<span> used as working electrode. The optimal conditions of separation and detection were pH 7.8 phosphate buffer (0.15</span></span> <!-->mol/l), 8<!--> <!-->kV for the separation voltage and 0.95<!--> <!-->V (versus Ag/AgCl, 3<!--> <!-->mol/l KCl) for the detection potential. The linear range was from 2×10<sup>−6</sup> to 2×10<sup>−4</sup> <span>mol/l with the regression coefficient<span> of 0.9995, and the detection limit was 8×10</span></span><sup>−7</sup> <!-->mol/l. The method built in this paper was directly applied to the determination of daunorubicin in the imitation human urine without any other sample pre-treatment except filtration, and the assay result was satisfactory.</div></div>\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":\"416 1\",\"pages\":\"Pages 15-19\"},\"PeriodicalIF\":6.0000,\"publicationDate\":\"2000-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003267000008564\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2000/6/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267000008564","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2000/6/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Determination of daunorubicin in human urine by capillary zone electrophoresis with amperometric detection
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, for the determination of daunorubicin in human urine is described in this paper. A carbon disk electrode used as working electrode. The optimal conditions of separation and detection were pH 7.8 phosphate buffer (0.15 mol/l), 8 kV for the separation voltage and 0.95 V (versus Ag/AgCl, 3 mol/l KCl) for the detection potential. The linear range was from 2×10−6 to 2×10−4mol/l with the regression coefficient of 0.9995, and the detection limit was 8×10−7 mol/l. The method built in this paper was directly applied to the determination of daunorubicin in the imitation human urine without any other sample pre-treatment except filtration, and the assay result was satisfactory.
期刊介绍:
Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review.
Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.