{"title":"比较预科药物的稳定性,使用迫击炮和Crusher药片在药房的主要卫生设施","authors":"M. Jaya","doi":"10.24843/jfu.2020.v09.i02.p06","DOIUrl":null,"url":null,"abstract":"Background: Drugs crushed using mortar is indeed already assessed according the procedure and maintained stability of the cure. But this process requires a relatively long that made some pharmacies preparing medications using a tablet crusher machine. There is a possibility of crushed using a tablet crusher will reduce the stability of certain types of drugs if direct contact with the metal blender machine. Purpose: the variable examined was the stability of the region, namely drug comparison of levels of a drug that dipreparasi uses a tablet crusher and mortar in the primary health care facility pharmacies. Methods: UV-VIS spectrophotometry. Results: the maximum wavelength of klorfeniramine maleate acquired was 261.5 nm and paracetamol is 247.7 nm. % recovery of klorfeniramine maleate raw is ± 2.8% whereas 99.82 on paracetamol is 2.09% ± 100.17. The result of the calculation precision value was obtained by tests at on klorfeniramine maleate is 0.76% whereas on paracetamol is 1.13%. LOD and LOQ of klorfeniramine maleate is 3.20 ± 0.05 and 0.15 ± 9.7 while the LOD and LOQ of paracetamol is 0.38 ± 0.22 and 1.16 ± 0.56. Preparation of comparative test results time crushed with a levels has been made aware that the value of significance test of the Mann Whitney absence of difference levels of drugs that are dipreparasi using mortars and tablet crusher. Conclusion: Drug Crushed with tablet crusher and with mortar does not have the difference statistically. \nKeyword: blender, crusher, mortars, stability","PeriodicalId":17752,"journal":{"name":"Jurnal Farmasi Udayana","volume":"155 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Perbandingan Stabilitas Obat Racikan Yang Dipreparasi Menggunakan Mortir Dan Tablet Crusher Di Apotek Sarana Pelayanan Kesehatan Primer\",\"authors\":\"M. Jaya\",\"doi\":\"10.24843/jfu.2020.v09.i02.p06\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Drugs crushed using mortar is indeed already assessed according the procedure and maintained stability of the cure. But this process requires a relatively long that made some pharmacies preparing medications using a tablet crusher machine. There is a possibility of crushed using a tablet crusher will reduce the stability of certain types of drugs if direct contact with the metal blender machine. Purpose: the variable examined was the stability of the region, namely drug comparison of levels of a drug that dipreparasi uses a tablet crusher and mortar in the primary health care facility pharmacies. Methods: UV-VIS spectrophotometry. Results: the maximum wavelength of klorfeniramine maleate acquired was 261.5 nm and paracetamol is 247.7 nm. % recovery of klorfeniramine maleate raw is ± 2.8% whereas 99.82 on paracetamol is 2.09% ± 100.17. The result of the calculation precision value was obtained by tests at on klorfeniramine maleate is 0.76% whereas on paracetamol is 1.13%. LOD and LOQ of klorfeniramine maleate is 3.20 ± 0.05 and 0.15 ± 9.7 while the LOD and LOQ of paracetamol is 0.38 ± 0.22 and 1.16 ± 0.56. Preparation of comparative test results time crushed with a levels has been made aware that the value of significance test of the Mann Whitney absence of difference levels of drugs that are dipreparasi using mortars and tablet crusher. Conclusion: Drug Crushed with tablet crusher and with mortar does not have the difference statistically. \\nKeyword: blender, crusher, mortars, stability\",\"PeriodicalId\":17752,\"journal\":{\"name\":\"Jurnal Farmasi Udayana\",\"volume\":\"155 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Farmasi Udayana\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24843/jfu.2020.v09.i02.p06\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Farmasi Udayana","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24843/jfu.2020.v09.i02.p06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Perbandingan Stabilitas Obat Racikan Yang Dipreparasi Menggunakan Mortir Dan Tablet Crusher Di Apotek Sarana Pelayanan Kesehatan Primer
Background: Drugs crushed using mortar is indeed already assessed according the procedure and maintained stability of the cure. But this process requires a relatively long that made some pharmacies preparing medications using a tablet crusher machine. There is a possibility of crushed using a tablet crusher will reduce the stability of certain types of drugs if direct contact with the metal blender machine. Purpose: the variable examined was the stability of the region, namely drug comparison of levels of a drug that dipreparasi uses a tablet crusher and mortar in the primary health care facility pharmacies. Methods: UV-VIS spectrophotometry. Results: the maximum wavelength of klorfeniramine maleate acquired was 261.5 nm and paracetamol is 247.7 nm. % recovery of klorfeniramine maleate raw is ± 2.8% whereas 99.82 on paracetamol is 2.09% ± 100.17. The result of the calculation precision value was obtained by tests at on klorfeniramine maleate is 0.76% whereas on paracetamol is 1.13%. LOD and LOQ of klorfeniramine maleate is 3.20 ± 0.05 and 0.15 ± 9.7 while the LOD and LOQ of paracetamol is 0.38 ± 0.22 and 1.16 ± 0.56. Preparation of comparative test results time crushed with a levels has been made aware that the value of significance test of the Mann Whitney absence of difference levels of drugs that are dipreparasi using mortars and tablet crusher. Conclusion: Drug Crushed with tablet crusher and with mortar does not have the difference statistically.
Keyword: blender, crusher, mortars, stability