{"title":"楔形传输系数对co-60远程治疗深度和技术的影响","authors":"S. Tagoe, E. Nani, E. Addison, A. Andam","doi":"10.4314/JAST.V16I1-2.64790","DOIUrl":null,"url":null,"abstract":"Measuring the wedge factor (WF) for radiation field of 10 x 10 cm2 at a specified depth and Source to Surface Distance (SSD), and applying the value to all treatment depths and technique could introduce errors > ± 5 % of threshold stipulated for patient radiation dose delivery. Therefore, some Treatment Planning Systems (TPSs) provide for inputs of separate Percentage Depth Dose (PDD) and Tissue Phantom Ratio (TPR) data for wedged fields to account for WF dependence of treatment depths and techniques. Hence, relatively more measurements than usual are taken per wedge filter and photon energy to establish a TPS and obtain dosimetric data for estima-ting treatment time for wedged fields, which required sophisticated equipment and procedures. While many On-cology Centres rely on International PDD and Tissue Maximum Ratio (TMR) data, benchmark data for wedged beams are not readily available. To provide radiotherapy dosimetry of high accuracy and expediency, two emp-irical equations were developed for a GWGP 80 Cobalt-60 teletherapy machine at the Oncology Department, Korle Bu Teaching Hospital (Ghana). The equations were validated via linear interpolations by measuring WFs at various treatment depths using Source Axial distance (SAD) and SSD treatment techniques. The approach required only measurements of WF for a 10 x 10 cm2 field at depth of 5 cm employing SSD treatment technique per wedge filter. Using the empirical equations, WFs were determined to within ± 0.50 % of the measured valu-es over the entire treatment depth range of 1.5 to 15.5 cm for SAD and SSD treatment techniques respectively; and WFs could be obtained for any treatment depth and technique.","PeriodicalId":9207,"journal":{"name":"British Journal of Applied Science and Technology","volume":"3 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2011-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Dependence of wedge transmission factor on co-60 teletherapy treatment depths and techniques\",\"authors\":\"S. Tagoe, E. Nani, E. Addison, A. Andam\",\"doi\":\"10.4314/JAST.V16I1-2.64790\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measuring the wedge factor (WF) for radiation field of 10 x 10 cm2 at a specified depth and Source to Surface Distance (SSD), and applying the value to all treatment depths and technique could introduce errors > ± 5 % of threshold stipulated for patient radiation dose delivery. Therefore, some Treatment Planning Systems (TPSs) provide for inputs of separate Percentage Depth Dose (PDD) and Tissue Phantom Ratio (TPR) data for wedged fields to account for WF dependence of treatment depths and techniques. Hence, relatively more measurements than usual are taken per wedge filter and photon energy to establish a TPS and obtain dosimetric data for estima-ting treatment time for wedged fields, which required sophisticated equipment and procedures. While many On-cology Centres rely on International PDD and Tissue Maximum Ratio (TMR) data, benchmark data for wedged beams are not readily available. To provide radiotherapy dosimetry of high accuracy and expediency, two emp-irical equations were developed for a GWGP 80 Cobalt-60 teletherapy machine at the Oncology Department, Korle Bu Teaching Hospital (Ghana). The equations were validated via linear interpolations by measuring WFs at various treatment depths using Source Axial distance (SAD) and SSD treatment techniques. The approach required only measurements of WF for a 10 x 10 cm2 field at depth of 5 cm employing SSD treatment technique per wedge filter. Using the empirical equations, WFs were determined to within ± 0.50 % of the measured valu-es over the entire treatment depth range of 1.5 to 15.5 cm for SAD and SSD treatment techniques respectively; and WFs could be obtained for any treatment depth and technique.\",\"PeriodicalId\":9207,\"journal\":{\"name\":\"British Journal of Applied Science and Technology\",\"volume\":\"3 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British Journal of Applied Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4314/JAST.V16I1-2.64790\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Applied Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4314/JAST.V16I1-2.64790","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
在指定深度和源表面距离(SSD)下测量10 x 10 cm2辐射场的楔形因子(WF),并将该值应用于所有治疗深度和技术,可能会引入误差>患者辐射剂量传递规定阈值的±5%。因此,一些治疗计划系统(tps)为楔形场提供单独的百分比深度剂量(PDD)和组织幻像比(TPR)数据输入,以说明治疗深度和技术对WF的依赖。因此,相对而言,每个楔形滤波器和光子能量需要比通常更多的测量来建立TPS并获得剂量学数据以估计楔形场的处理时间,这需要复杂的设备和程序。虽然许多生态中心依赖国际PDD和组织最大比(TMR)数据,但楔形光束的基准数据并不容易获得。为了提供高精度和方便的放射剂量测定,为加纳科尔布教学医院肿瘤科的GWGP 80钴-60远程治疗机开发了两个经验方程。通过使用源轴向距离(SAD)和SSD处理技术测量不同处理深度的wf,通过线性插值验证了方程。该方法只需要在深度为5厘米的10 × 10平方厘米的场中测量WF,每个楔形滤波器采用SSD处理技术。利用经验方程,确定了SAD和SSD处理技术在1.5 ~ 15.5 cm的整个处理深度范围内的wf值与实测值的±0.50%;在任何处理深度和处理技术下均可获得WFs。
Dependence of wedge transmission factor on co-60 teletherapy treatment depths and techniques
Measuring the wedge factor (WF) for radiation field of 10 x 10 cm2 at a specified depth and Source to Surface Distance (SSD), and applying the value to all treatment depths and technique could introduce errors > ± 5 % of threshold stipulated for patient radiation dose delivery. Therefore, some Treatment Planning Systems (TPSs) provide for inputs of separate Percentage Depth Dose (PDD) and Tissue Phantom Ratio (TPR) data for wedged fields to account for WF dependence of treatment depths and techniques. Hence, relatively more measurements than usual are taken per wedge filter and photon energy to establish a TPS and obtain dosimetric data for estima-ting treatment time for wedged fields, which required sophisticated equipment and procedures. While many On-cology Centres rely on International PDD and Tissue Maximum Ratio (TMR) data, benchmark data for wedged beams are not readily available. To provide radiotherapy dosimetry of high accuracy and expediency, two emp-irical equations were developed for a GWGP 80 Cobalt-60 teletherapy machine at the Oncology Department, Korle Bu Teaching Hospital (Ghana). The equations were validated via linear interpolations by measuring WFs at various treatment depths using Source Axial distance (SAD) and SSD treatment techniques. The approach required only measurements of WF for a 10 x 10 cm2 field at depth of 5 cm employing SSD treatment technique per wedge filter. Using the empirical equations, WFs were determined to within ± 0.50 % of the measured valu-es over the entire treatment depth range of 1.5 to 15.5 cm for SAD and SSD treatment techniques respectively; and WFs could be obtained for any treatment depth and technique.