Evelina Wikner , Erik Björklund , Johan Fridner , Daniel Brandell , Torbjörn Thiringer
{"title":"商用锂离子袋电池中使用的SOC窗口如何影响电池老化","authors":"Evelina Wikner , Erik Björklund , Johan Fridner , Daniel Brandell , Torbjörn Thiringer","doi":"10.1016/j.powera.2021.100054","DOIUrl":null,"url":null,"abstract":"<div><p>In many lithium-ion battery (LIB) applications, e.g. hybrid vehicles and load-levelling storage systems, only part of the state-of-charge (SOC) range needs to be utilised. This offers the possibility to use an optimal SOC window to avoid LIB ageing. Here, a large test matrix is designed to study LIB ageing in a commercial 26 Ah pouch cell, in order to map the ageing behaviour at different SOC levels with respect to temperature and current. A quantification of the degradation modes, loss of lithium inventory (LLI), loss of active positive (LAM<sub><em>PE</em></sub>) and negative (LAM<sub><em>NE</em></sub>) electrode materials is made by analysing the change in the open circuit voltage (OCV). A key result is that lower SOC intervals significantly improved battery ageing. Even during harsh test conditions, such as high C-rates and temperatures, the cells deliver more than three times the expected number of full cycle equivalents. High SOC combined with high C-rate increase ageing where the dominating ageing mechanisms are LLI, followed by LAM<sub><em>PE</em></sub>.</p></div>","PeriodicalId":34318,"journal":{"name":"Journal of Power Sources Advances","volume":"8 ","pages":"Article 100054"},"PeriodicalIF":5.4000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.powera.2021.100054","citationCount":"11","resultStr":"{\"title\":\"How the utilised SOC window in commercial Li-ion pouch cells influence battery ageing\",\"authors\":\"Evelina Wikner , Erik Björklund , Johan Fridner , Daniel Brandell , Torbjörn Thiringer\",\"doi\":\"10.1016/j.powera.2021.100054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In many lithium-ion battery (LIB) applications, e.g. hybrid vehicles and load-levelling storage systems, only part of the state-of-charge (SOC) range needs to be utilised. This offers the possibility to use an optimal SOC window to avoid LIB ageing. Here, a large test matrix is designed to study LIB ageing in a commercial 26 Ah pouch cell, in order to map the ageing behaviour at different SOC levels with respect to temperature and current. A quantification of the degradation modes, loss of lithium inventory (LLI), loss of active positive (LAM<sub><em>PE</em></sub>) and negative (LAM<sub><em>NE</em></sub>) electrode materials is made by analysing the change in the open circuit voltage (OCV). A key result is that lower SOC intervals significantly improved battery ageing. Even during harsh test conditions, such as high C-rates and temperatures, the cells deliver more than three times the expected number of full cycle equivalents. High SOC combined with high C-rate increase ageing where the dominating ageing mechanisms are LLI, followed by LAM<sub><em>PE</em></sub>.</p></div>\",\"PeriodicalId\":34318,\"journal\":{\"name\":\"Journal of Power Sources Advances\",\"volume\":\"8 \",\"pages\":\"Article 100054\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.powera.2021.100054\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Power Sources Advances\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666248521000093\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Power Sources Advances","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666248521000093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
How the utilised SOC window in commercial Li-ion pouch cells influence battery ageing
In many lithium-ion battery (LIB) applications, e.g. hybrid vehicles and load-levelling storage systems, only part of the state-of-charge (SOC) range needs to be utilised. This offers the possibility to use an optimal SOC window to avoid LIB ageing. Here, a large test matrix is designed to study LIB ageing in a commercial 26 Ah pouch cell, in order to map the ageing behaviour at different SOC levels with respect to temperature and current. A quantification of the degradation modes, loss of lithium inventory (LLI), loss of active positive (LAMPE) and negative (LAMNE) electrode materials is made by analysing the change in the open circuit voltage (OCV). A key result is that lower SOC intervals significantly improved battery ageing. Even during harsh test conditions, such as high C-rates and temperatures, the cells deliver more than three times the expected number of full cycle equivalents. High SOC combined with high C-rate increase ageing where the dominating ageing mechanisms are LLI, followed by LAMPE.