T-Scan 数字化咬合定量分析技术的临床应用:系统综述。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Computerized Dentistry Pub Date : 2024-03-26 DOI:10.3290/j.ijcd.b3945153
Ramesh Chowdhary, Nithin Kumar Sonnahalli
{"title":"T-Scan 数字化咬合定量分析技术的临床应用:系统综述。","authors":"Ramesh Chowdhary, Nithin Kumar Sonnahalli","doi":"10.3290/j.ijcd.b3945153","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of the problem: </strong>Occlusion is associated with all disciplines of dentistry and plays a major role in the longevity of both implant- and tooth-borne restorations. Achieving occlusal harmony ensures balance is established between the dental and myofascial structures, which can be measurably established to high numerical tolerances with the T-Scan digital occlusal analysis system.</p><p><strong>Purpose: </strong>To describe and evaluate the known and proven applications of T-Scan digital occlusal analysis in various dental practice disciplines through a systematic review of the literature.</p><p><strong>Materials and methods: </strong>An electronic, English-language PubMed/MEDLINE and Cochrane Central Registry of Controlled Trials database search using the keywords \"T-Scan,\" \"TMD,\" \"Occlusion,\" \"Implant Protected Occlusion,\" and \"Orthodontics\" was conducted without any date restrictions. The related journal findings were hand searched to determine studies that met the eligibility criteria for inclusion in the present systematic review.</p><p><strong>Results: </strong>The PubMed/MEDLINE search identified 423 articles. After removing duplicates, the titles and abstracts of the remaining 421 studies were screened. 274 ineligible articles were excluded, leaving 147 articles. Of those, 33 articles were not in English, 27 full-text articles were not available, 4 were comments and letters to editors, 1 was a review, and 2 described techniques. A total of 86 articles met the eligibility criteria for inclusion.</p><p><strong>Conclusion: </strong>Much scientific evidence supports the use of T-Scan, as it measures relative occlusal contact forces and the time sequence durations of occlusal contacts objectively, accurately, and repeatedly for improved treatment outcomes. The system's hardware, sensor, and software evolution from T-Scan I to today's T-Scan 10 Novus system has overcome early sensor and system drawbacks to improve the clinical performance of T-Scan in many disciplines of dental medicine.</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"0 0","pages":"49-86"},"PeriodicalIF":1.8000,"publicationDate":"2024-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical applications of the T-Scan quantitative digital occlusal analysis technology: a systematic review.\",\"authors\":\"Ramesh Chowdhary, Nithin Kumar Sonnahalli\",\"doi\":\"10.3290/j.ijcd.b3945153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of the problem: </strong>Occlusion is associated with all disciplines of dentistry and plays a major role in the longevity of both implant- and tooth-borne restorations. Achieving occlusal harmony ensures balance is established between the dental and myofascial structures, which can be measurably established to high numerical tolerances with the T-Scan digital occlusal analysis system.</p><p><strong>Purpose: </strong>To describe and evaluate the known and proven applications of T-Scan digital occlusal analysis in various dental practice disciplines through a systematic review of the literature.</p><p><strong>Materials and methods: </strong>An electronic, English-language PubMed/MEDLINE and Cochrane Central Registry of Controlled Trials database search using the keywords \\\"T-Scan,\\\" \\\"TMD,\\\" \\\"Occlusion,\\\" \\\"Implant Protected Occlusion,\\\" and \\\"Orthodontics\\\" was conducted without any date restrictions. The related journal findings were hand searched to determine studies that met the eligibility criteria for inclusion in the present systematic review.</p><p><strong>Results: </strong>The PubMed/MEDLINE search identified 423 articles. After removing duplicates, the titles and abstracts of the remaining 421 studies were screened. 274 ineligible articles were excluded, leaving 147 articles. Of those, 33 articles were not in English, 27 full-text articles were not available, 4 were comments and letters to editors, 1 was a review, and 2 described techniques. A total of 86 articles met the eligibility criteria for inclusion.</p><p><strong>Conclusion: </strong>Much scientific evidence supports the use of T-Scan, as it measures relative occlusal contact forces and the time sequence durations of occlusal contacts objectively, accurately, and repeatedly for improved treatment outcomes. The system's hardware, sensor, and software evolution from T-Scan I to today's T-Scan 10 Novus system has overcome early sensor and system drawbacks to improve the clinical performance of T-Scan in many disciplines of dental medicine.</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"0 0\",\"pages\":\"49-86\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b3945153\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b3945153","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题简介:咬合与牙科的所有学科都有关系,对种植体和牙本质修复体的寿命起着重要作用。实现咬合和谐可确保在牙齿和肌筋膜结构之间建立平衡,T-Scan 数字咬合分析系统可对这一平衡进行测量,以达到较高的数字公差。目的:通过对文献进行系统性回顾,描述和评估 T-Scan 数字咬合分析在各种牙科实践中已知和已证实的应用:使用关键词 "T-Scan"、"TMD"、"咬合"、"种植体保护咬合 "和 "正畸 "进行电子版、英文版 PubMed/MEDLINE 和 Cochrane Central Registry of Controlled Trials 数据库检索,没有任何日期限制。对相关期刊的研究结果进行了人工检索,以确定哪些研究符合纳入本系统综述的资格标准:PubMed/MEDLINE检索共发现423篇文章。在删除重复文章后,对剩余 421 篇研究的标题和摘要进行了筛选。排除了 274 篇不符合条件的文章,剩下 147 篇。其中,33 篇文章不是英文的,27 篇文章没有全文,4 篇是评论和致编辑的信,1 篇是综述,2 篇描述了技术。共有 86 篇文章符合纳入标准:许多科学证据都支持使用 T-Scan,因为它能客观、准确、反复地测量相对咬合接触力和咬合接触的时序持续时间,从而改善治疗效果。从 T-Scan I 到今天的 T-Scan 10 Novus 系统,该系统的硬件、传感器和软件不断发展,克服了早期传感器和系统的缺陷,提高了 T-Scan 在牙科医学许多学科中的临床表现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical applications of the T-Scan quantitative digital occlusal analysis technology: a systematic review.

Statement of the problem: Occlusion is associated with all disciplines of dentistry and plays a major role in the longevity of both implant- and tooth-borne restorations. Achieving occlusal harmony ensures balance is established between the dental and myofascial structures, which can be measurably established to high numerical tolerances with the T-Scan digital occlusal analysis system.

Purpose: To describe and evaluate the known and proven applications of T-Scan digital occlusal analysis in various dental practice disciplines through a systematic review of the literature.

Materials and methods: An electronic, English-language PubMed/MEDLINE and Cochrane Central Registry of Controlled Trials database search using the keywords "T-Scan," "TMD," "Occlusion," "Implant Protected Occlusion," and "Orthodontics" was conducted without any date restrictions. The related journal findings were hand searched to determine studies that met the eligibility criteria for inclusion in the present systematic review.

Results: The PubMed/MEDLINE search identified 423 articles. After removing duplicates, the titles and abstracts of the remaining 421 studies were screened. 274 ineligible articles were excluded, leaving 147 articles. Of those, 33 articles were not in English, 27 full-text articles were not available, 4 were comments and letters to editors, 1 was a review, and 2 described techniques. A total of 86 articles met the eligibility criteria for inclusion.

Conclusion: Much scientific evidence supports the use of T-Scan, as it measures relative occlusal contact forces and the time sequence durations of occlusal contacts objectively, accurately, and repeatedly for improved treatment outcomes. The system's hardware, sensor, and software evolution from T-Scan I to today's T-Scan 10 Novus system has overcome early sensor and system drawbacks to improve the clinical performance of T-Scan in many disciplines of dental medicine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
期刊最新文献
Accuracy of complete-arch, All-on-4 implant scans under simulated intraoral variables. Accuracy of intraoral scanners in neonates cleft anatomy. Effect of the abutment shape on soft tissue healing. A randomized clinical pilot study involving a digital superposition methodology. Intraoral scanning accuracy and trueness for different dental restorations. OccluSense: Reliability, influencing factors and limitations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1