Gunter Spahn, Milot Ramadani, Stephan Günther, Cornelia Retzlaff, Holm Torsten Klemm, Michael Meyer-Clement, Gunther O Hofmann
{"title":"腰椎椎间盘高度的测量。比较 X 射线和磁共振成像、测量方法以及确定观察者之间的可靠性。","authors":"Gunter Spahn, Milot Ramadani, Stephan Günther, Cornelia Retzlaff, Holm Torsten Klemm, Michael Meyer-Clement, Gunther O Hofmann","doi":"10.1055/a-1994-0879","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Retrospective radiological examination (X-ray and MRI) aims to investigate the diagnostic value of various methods of measurement with regard to the determination of the intervertebral disc heights of the lumbar spine.</p><p><strong>Methods: </strong>Of 130 patients without detectable damage to the intervertebral discs, the X-ray and MRI images of the lumbar spine were evaluated. The measurements were made either in the center line (Hurxthal) or in the 2-point method according to Dabbs or in the 3-point method according to Fyllos.</p><p><strong>Results: </strong>The average intervertebral disc height for all measured segments was 8.8 mm (SD 1.4 mm). In the Hurxthal measurement, the significantly (p < 0.001) highest values were measured with an average of 9.1 mm (SD 1.3 mm). The average readings for the Fyllos method were 7.5 mm (SD 1.2 mm) and according to Dabbs 6.7 mm (SD 1.2 mm). The measured values of Observer I were on average 1.2 mm (SD 0.3 mm) smaller than those of Observer II (p < 0.001). The highest interobserver correlation was found in the measurements in projection radiography in the AP method according to Dabbs and Fyllos. The measured values in men were 0.5 mm (SD 0.01 mm) larger than in women (p < 0.001), regardless of the method. The height of the intervertebral discs increases significantly until the age of 40, but beyond the age of 40, the height of the intervertebral discs either remains constant or falls off slightly, but not significantly. The lordosis angle of the lumbar spine and the concavity index of the vertebral bodies showed no correlation with the measured disc heights.</p><p><strong>Conclusions: </strong>The radiological measurements to determine the intervertebral disc height have only moderate reliability. The results of X-rays are superior to those of MRI examination. The most accurate results are provided by measurements based on exact landmarks of the vertebral bodies. The method according to Dabbs seems to be the most accurate at the moment. There is no clear age-atypical chondrosis in patients without intervertebral disc damage.</p>","PeriodicalId":51219,"journal":{"name":"Zeitschrift Fur Orthopadie Und Unfallchirurgie","volume":" ","pages":"254-262"},"PeriodicalIF":1.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of Intervertebral Disc Heights in the Lumbar Spine. Comparison of X-Ray and Magnetic Resonance Imaging, Method of Measurement and Determination of Inter-observer Reliability.\",\"authors\":\"Gunter Spahn, Milot Ramadani, Stephan Günther, Cornelia Retzlaff, Holm Torsten Klemm, Michael Meyer-Clement, Gunther O Hofmann\",\"doi\":\"10.1055/a-1994-0879\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Retrospective radiological examination (X-ray and MRI) aims to investigate the diagnostic value of various methods of measurement with regard to the determination of the intervertebral disc heights of the lumbar spine.</p><p><strong>Methods: </strong>Of 130 patients without detectable damage to the intervertebral discs, the X-ray and MRI images of the lumbar spine were evaluated. The measurements were made either in the center line (Hurxthal) or in the 2-point method according to Dabbs or in the 3-point method according to Fyllos.</p><p><strong>Results: </strong>The average intervertebral disc height for all measured segments was 8.8 mm (SD 1.4 mm). In the Hurxthal measurement, the significantly (p < 0.001) highest values were measured with an average of 9.1 mm (SD 1.3 mm). The average readings for the Fyllos method were 7.5 mm (SD 1.2 mm) and according to Dabbs 6.7 mm (SD 1.2 mm). The measured values of Observer I were on average 1.2 mm (SD 0.3 mm) smaller than those of Observer II (p < 0.001). The highest interobserver correlation was found in the measurements in projection radiography in the AP method according to Dabbs and Fyllos. The measured values in men were 0.5 mm (SD 0.01 mm) larger than in women (p < 0.001), regardless of the method. The height of the intervertebral discs increases significantly until the age of 40, but beyond the age of 40, the height of the intervertebral discs either remains constant or falls off slightly, but not significantly. The lordosis angle of the lumbar spine and the concavity index of the vertebral bodies showed no correlation with the measured disc heights.</p><p><strong>Conclusions: </strong>The radiological measurements to determine the intervertebral disc height have only moderate reliability. The results of X-rays are superior to those of MRI examination. The most accurate results are provided by measurements based on exact landmarks of the vertebral bodies. The method according to Dabbs seems to be the most accurate at the moment. There is no clear age-atypical chondrosis in patients without intervertebral disc damage.</p>\",\"PeriodicalId\":51219,\"journal\":{\"name\":\"Zeitschrift Fur Orthopadie Und Unfallchirurgie\",\"volume\":\" \",\"pages\":\"254-262\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift Fur Orthopadie Und Unfallchirurgie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-1994-0879\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/2/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift Fur Orthopadie Und Unfallchirurgie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1994-0879","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/2/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Measurement of Intervertebral Disc Heights in the Lumbar Spine. Comparison of X-Ray and Magnetic Resonance Imaging, Method of Measurement and Determination of Inter-observer Reliability.
Purpose: Retrospective radiological examination (X-ray and MRI) aims to investigate the diagnostic value of various methods of measurement with regard to the determination of the intervertebral disc heights of the lumbar spine.
Methods: Of 130 patients without detectable damage to the intervertebral discs, the X-ray and MRI images of the lumbar spine were evaluated. The measurements were made either in the center line (Hurxthal) or in the 2-point method according to Dabbs or in the 3-point method according to Fyllos.
Results: The average intervertebral disc height for all measured segments was 8.8 mm (SD 1.4 mm). In the Hurxthal measurement, the significantly (p < 0.001) highest values were measured with an average of 9.1 mm (SD 1.3 mm). The average readings for the Fyllos method were 7.5 mm (SD 1.2 mm) and according to Dabbs 6.7 mm (SD 1.2 mm). The measured values of Observer I were on average 1.2 mm (SD 0.3 mm) smaller than those of Observer II (p < 0.001). The highest interobserver correlation was found in the measurements in projection radiography in the AP method according to Dabbs and Fyllos. The measured values in men were 0.5 mm (SD 0.01 mm) larger than in women (p < 0.001), regardless of the method. The height of the intervertebral discs increases significantly until the age of 40, but beyond the age of 40, the height of the intervertebral discs either remains constant or falls off slightly, but not significantly. The lordosis angle of the lumbar spine and the concavity index of the vertebral bodies showed no correlation with the measured disc heights.
Conclusions: The radiological measurements to determine the intervertebral disc height have only moderate reliability. The results of X-rays are superior to those of MRI examination. The most accurate results are provided by measurements based on exact landmarks of the vertebral bodies. The method according to Dabbs seems to be the most accurate at the moment. There is no clear age-atypical chondrosis in patients without intervertebral disc damage.
期刊介绍:
Das Forum für Orthopädie und Unfallchirurgie aus einer Hand
Aktuelles aus Klinik, Wissenschaft und Forschung
Ein unabhängiges Peer-Review-Verfahren sichert Qualität, Relevanz und Plausibilität der Daten
Modernes Layout: Klare Gliederung, farbige Abbildungen, strukturierte Tabellen
Orthopädie und Unfallchirurgie aktuell: Berichte und Reportagen zu den wichtigsten Themen im Fach