运动开始检测方法:使用力板记录的比较。

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Applied Biomechanics Pub Date : 2023-04-01 DOI:10.1123/jab.2022-0111
Brendan L Pinto, Jack P Callaghan
{"title":"运动开始检测方法:使用力板记录的比较。","authors":"Brendan L Pinto,&nbsp;Jack P Callaghan","doi":"10.1123/jab.2022-0111","DOIUrl":null,"url":null,"abstract":"<p><p>Computational approaches for movement onset detection can standardize and automate analyses to improve repeatability, accessibility, and time efficiency. With the increasing interest in assessing time-varying biomechanical signals such as force-time recordings, there remains a need to investigate the recently adopted 5 times the standard deviation (5 × SD) threshold method. In addition, other employed methods and their variations such as the reverse scanning and first derivative methods have been scarcely evaluated. The aim of this study was to compare the 5 × SD threshold method, 3 variations of the reverse scanning method, and 5 variations of the first derivative method against manually selected onsets, in the countermovement jump and squat. Limits of agreement with respect to onsets, manually selected from unfiltered data, were best for the first derivative method using a 10-Hz low-pass filter (limits of agreement: -0.02 to 0.05 s and -0.07 to 0.11 s for the countermovement jump and squat, respectively). Thus, even when the onset of unfiltered data is of primary interest, filtering before calculating the first derivative is necessary as it reduces the amplification of high frequencies. The first derivative approach is also less susceptible to inherent variation during the quiet phase prior to the onset compared to the other approaches investigated.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"39 2","pages":"118-123"},"PeriodicalIF":1.1000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Movement Onset Detection Methods: A Comparison Using Force Plate Recordings.\",\"authors\":\"Brendan L Pinto,&nbsp;Jack P Callaghan\",\"doi\":\"10.1123/jab.2022-0111\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Computational approaches for movement onset detection can standardize and automate analyses to improve repeatability, accessibility, and time efficiency. With the increasing interest in assessing time-varying biomechanical signals such as force-time recordings, there remains a need to investigate the recently adopted 5 times the standard deviation (5 × SD) threshold method. In addition, other employed methods and their variations such as the reverse scanning and first derivative methods have been scarcely evaluated. The aim of this study was to compare the 5 × SD threshold method, 3 variations of the reverse scanning method, and 5 variations of the first derivative method against manually selected onsets, in the countermovement jump and squat. Limits of agreement with respect to onsets, manually selected from unfiltered data, were best for the first derivative method using a 10-Hz low-pass filter (limits of agreement: -0.02 to 0.05 s and -0.07 to 0.11 s for the countermovement jump and squat, respectively). Thus, even when the onset of unfiltered data is of primary interest, filtering before calculating the first derivative is necessary as it reduces the amplification of high frequencies. The first derivative approach is also less susceptible to inherent variation during the quiet phase prior to the onset compared to the other approaches investigated.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":\"39 2\",\"pages\":\"118-123\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2022-0111\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0111","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

运动开始检测的计算方法可以标准化和自动化分析,以提高可重复性,可访问性和时间效率。随着人们对评估时变生物力学信号(如力-时间记录)的兴趣日益浓厚,仍有必要研究最近采用的5倍标准偏差(5 × SD)阈值方法。此外,其他常用的方法及其变体,如反扫描法和一阶导数法,几乎没有得到评价。本研究的目的是比较5 × SD阈值法、3种不同的反向扫描法和5种不同的一阶导数法对人工选择起跳动作的影响。对于使用10 hz低通滤波器的一阶导数方法,从未过滤的数据中手动选择的起跳的一致性限制是最好的(一致性限制分别为-0.02至0.05秒和-0.07至0.11秒)。因此,即使对未滤波数据的初始值最感兴趣,在计算一阶导数之前进行滤波也是必要的,因为这样可以减少高频的放大。与所研究的其他方法相比,一阶导数方法在发病前的安静阶段也不容易受到固有变化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Movement Onset Detection Methods: A Comparison Using Force Plate Recordings.

Computational approaches for movement onset detection can standardize and automate analyses to improve repeatability, accessibility, and time efficiency. With the increasing interest in assessing time-varying biomechanical signals such as force-time recordings, there remains a need to investigate the recently adopted 5 times the standard deviation (5 × SD) threshold method. In addition, other employed methods and their variations such as the reverse scanning and first derivative methods have been scarcely evaluated. The aim of this study was to compare the 5 × SD threshold method, 3 variations of the reverse scanning method, and 5 variations of the first derivative method against manually selected onsets, in the countermovement jump and squat. Limits of agreement with respect to onsets, manually selected from unfiltered data, were best for the first derivative method using a 10-Hz low-pass filter (limits of agreement: -0.02 to 0.05 s and -0.07 to 0.11 s for the countermovement jump and squat, respectively). Thus, even when the onset of unfiltered data is of primary interest, filtering before calculating the first derivative is necessary as it reduces the amplification of high frequencies. The first derivative approach is also less susceptible to inherent variation during the quiet phase prior to the onset compared to the other approaches investigated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Biomechanics
Journal of Applied Biomechanics 医学-工程:生物医学
CiteScore
2.00
自引率
0.00%
发文量
47
审稿时长
6-12 weeks
期刊介绍: The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.
期刊最新文献
Role of Hip Internal Rotation Range and Foot Progression Angle for Preventing Jones Fracture During Crossover Cutting. The Effect of Step Frequency and Running Speed on the Coordination of the Pelvis and Thigh Segments During Running. Effects of Different Inertial Measurement Unit Sensor-to-Segment Calibrations on Clinical 3-Dimensional Humerothoracic Joint Angles Estimation. Enhancing Sprint Performance and Biomechanics in Semiprofessional Football Players Through Repeated-Sprint Training. Investigation of a Theoretical Model for the Rotational Shot Put Technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1