{"title":"静脉注射胰岛素制剂对心肌活力18F-FDG成像具有降低辐射照射剂量的潜力。","authors":"Yangchun Chen,&nbsp;Qingqing Wang,&nbsp;Peihao Huang,&nbsp;Yuehui Wang,&nbsp;Yuxuan Chen,&nbsp;Huilin Zhuo,&nbsp;Ruozhu Dai,&nbsp;Huoqiang Wang","doi":"10.1967/s002449912552","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Fluorine-18-fluorodeoxyglucose (<sup>18</sup>F-FDG) injection activity is positively associated with radiation dose and positron emission tomography (PET) image count. Measurement error is greater with smaller counts; therefore, precise analysis is needed to avoid high doses of radiation exposure caused by high <sup>18</sup>F-FDG injection. We aimed to identify and validate the optimal <sup>18</sup>F-FDG injection activity and acquisition time for cardiac viability imaging with intravenous insulin preparation administration based on fixed <sup>18</sup>F-FDG activity.</p><p><strong>Materials and methods: </strong>Cardiac PET images from 30 patients with coronary artery disease (CAD) were retrospectively reconstructed into different durations. An optimal product of the maximum standardized uptake value (SUV) of the myocardium, and segmental uptake (SU), and acquisition time (MSAT) was determined through a receiver operating characteristic curve.</p><p><strong>Results: </strong>The optimal acquisition time (OAT) was equal to MSAT divided by mean SUV of the myocardium (MyoSUV) and was validated in another 26 patients with CAD. The optimal MSAT was 848.2s. In the validation group, the OAT was 129±76s (95% confidence interval, 99-160s), approximately one-third of the usual acquisition time. The MyoSUV and SU were equivalent between PET image duration of OAT and 600s (7.71±3.01 vs. 7.56±2.94; 67.1±15.4% vs. 67.7±15.6%).</p><p><strong>Conclusion: </strong>Intravenous insulin preparation administration has the potential to decrease the radiation exposure or acquisition time in cardiac viability <sup>18</sup>F-FDG imaging to one-third, without losing the accurate measurement of MyoSUV or SU when reaching an OAT.</p>","PeriodicalId":12871,"journal":{"name":"Hellenic journal of nuclear medicine","volume":"26 1","pages":"20-25"},"PeriodicalIF":0.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intravenous insulin preparation administration for myocardial viability <sup>18</sup>F-FDG imaging has the potential to reduce radiation exposure dose.\",\"authors\":\"Yangchun Chen,&nbsp;Qingqing Wang,&nbsp;Peihao Huang,&nbsp;Yuehui Wang,&nbsp;Yuxuan Chen,&nbsp;Huilin Zhuo,&nbsp;Ruozhu Dai,&nbsp;Huoqiang Wang\",\"doi\":\"10.1967/s002449912552\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Fluorine-18-fluorodeoxyglucose (<sup>18</sup>F-FDG) injection activity is positively associated with radiation dose and positron emission tomography (PET) image count. Measurement error is greater with smaller counts; therefore, precise analysis is needed to avoid high doses of radiation exposure caused by high <sup>18</sup>F-FDG injection. We aimed to identify and validate the optimal <sup>18</sup>F-FDG injection activity and acquisition time for cardiac viability imaging with intravenous insulin preparation administration based on fixed <sup>18</sup>F-FDG activity.</p><p><strong>Materials and methods: </strong>Cardiac PET images from 30 patients with coronary artery disease (CAD) were retrospectively reconstructed into different durations. An optimal product of the maximum standardized uptake value (SUV) of the myocardium, and segmental uptake (SU), and acquisition time (MSAT) was determined through a receiver operating characteristic curve.</p><p><strong>Results: </strong>The optimal acquisition time (OAT) was equal to MSAT divided by mean SUV of the myocardium (MyoSUV) and was validated in another 26 patients with CAD. The optimal MSAT was 848.2s. In the validation group, the OAT was 129±76s (95% confidence interval, 99-160s), approximately one-third of the usual acquisition time. The MyoSUV and SU were equivalent between PET image duration of OAT and 600s (7.71±3.01 vs. 7.56±2.94; 67.1±15.4% vs. 67.7±15.6%).</p><p><strong>Conclusion: </strong>Intravenous insulin preparation administration has the potential to decrease the radiation exposure or acquisition time in cardiac viability <sup>18</sup>F-FDG imaging to one-third, without losing the accurate measurement of MyoSUV or SU when reaching an OAT.</p>\",\"PeriodicalId\":12871,\"journal\":{\"name\":\"Hellenic journal of nuclear medicine\",\"volume\":\"26 1\",\"pages\":\"20-25\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hellenic journal of nuclear medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1967/s002449912552\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hellenic journal of nuclear medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1967/s002449912552","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:氟-18-氟脱氧葡萄糖(18F-FDG)注射活性与辐射剂量和正电子发射断层扫描(PET)图像计数呈正相关。计数越小,测量误差越大;因此,需要精确的分析,以避免高剂量的18F-FDG注射造成的辐射暴露。我们的目的是在固定18F-FDG活性的基础上,确定并验证静脉注射胰岛素制剂时心脏活力成像的最佳18F-FDG注射活性和获取时间。材料与方法:对30例冠心病(CAD)患者的心脏PET图像进行回顾性重建。通过受体工作特性曲线确定心肌最大标准化摄取值(SUV)、节段摄取(SU)和获取时间(MSAT)的最佳乘积。结果:最佳获取时间(OAT)等于MSAT除以心肌平均SUV (MyoSUV),并在另外26例CAD患者中得到验证。最佳MSAT为848.2s。在验证组中,OAT为129±76秒(95%置信区间为99-160秒),约为通常获取时间的三分之一。MyoSUV和SU在OAT和600s PET图像持续时间之间相当(7.71±3.01 vs 7.56±2.94;67.1±15.4% vs. 67.7±15.6%)。结论:静脉注射胰岛素制剂有可能将心脏活力18F-FDG成像的辐射暴露或获取时间减少到三分之一,而在达到OAT时不会失去MyoSUV或SU的准确测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Intravenous insulin preparation administration for myocardial viability 18F-FDG imaging has the potential to reduce radiation exposure dose.

Objective: Fluorine-18-fluorodeoxyglucose (18F-FDG) injection activity is positively associated with radiation dose and positron emission tomography (PET) image count. Measurement error is greater with smaller counts; therefore, precise analysis is needed to avoid high doses of radiation exposure caused by high 18F-FDG injection. We aimed to identify and validate the optimal 18F-FDG injection activity and acquisition time for cardiac viability imaging with intravenous insulin preparation administration based on fixed 18F-FDG activity.

Materials and methods: Cardiac PET images from 30 patients with coronary artery disease (CAD) were retrospectively reconstructed into different durations. An optimal product of the maximum standardized uptake value (SUV) of the myocardium, and segmental uptake (SU), and acquisition time (MSAT) was determined through a receiver operating characteristic curve.

Results: The optimal acquisition time (OAT) was equal to MSAT divided by mean SUV of the myocardium (MyoSUV) and was validated in another 26 patients with CAD. The optimal MSAT was 848.2s. In the validation group, the OAT was 129±76s (95% confidence interval, 99-160s), approximately one-third of the usual acquisition time. The MyoSUV and SU were equivalent between PET image duration of OAT and 600s (7.71±3.01 vs. 7.56±2.94; 67.1±15.4% vs. 67.7±15.6%).

Conclusion: Intravenous insulin preparation administration has the potential to decrease the radiation exposure or acquisition time in cardiac viability 18F-FDG imaging to one-third, without losing the accurate measurement of MyoSUV or SU when reaching an OAT.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.40
自引率
6.70%
发文量
34
审稿时长
>12 weeks
期刊介绍: The Hellenic Journal of Nuclear Medicine published by the Hellenic Society of Nuclear Medicine in Thessaloniki, aims to contribute to research, to education and cover the scientific and professional interests of physicians, in the field of nuclear medicine and in medicine in general. The journal may publish papers of nuclear medicine and also papers that refer to related subjects as dosimetry, computer science, targeting of gene expression, radioimmunoassay, radiation protection, biology, cell trafficking, related historical brief reviews and other related subjects. Original papers are preferred. The journal may after special agreement publish supplements covering important subjects, dully reviewed and subscripted separately.
期刊最新文献
18F-FDG PET/CT image of NK/T cell lymphoma in the sacroiliac joint. 18F-FDG PET/CT imaging and curative effect evaluation of multiple muscular tuberculosis. A comparative review of the application value of FAPI PET/CT and 18F-FDG PET/CT in lung cancer. A head-to-head comparison of 18F-FDG PET/CT and 18F-FDG PET/MR in patients with nasopharyngeal carcinoma under different disease settings. Differentiated thyroid cancer with osteo-granulomatousinflammation: A case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1