Hansoul Kim, Jae Min You, Minho Hwang, Ki-Uk Kyung, Dong-Soo Kwon
{"title":"增强内镜手术超冗余度机械臂结构刚度的s型辅助肌腱驱动机构。","authors":"Hansoul Kim, Jae Min You, Minho Hwang, Ki-Uk Kyung, Dong-Soo Kwon","doi":"10.1089/soro.2021.0148","DOIUrl":null,"url":null,"abstract":"<p><p>The overtube of an endoscopic surgery robot is fixed when performing tasks, unlike those of commercial endoscopes, and this overtube should have high structural stiffness after reaching the target lesion so that sufficient tension can be applied to the lesion tissue with the surgical tool and there are fewer changes in the field of view of the endoscopic camera from this reaction force. Various methods have been proposed to reinforce the structural stiffnesses of hyper-redundant manipulators. However, the safety, rapid response, space efficiency, and cost-effectiveness of these methods should be considered for use in actual clinical environments, such as the gastrointestinal tract. This study proposed a method to minimize the positional changes of the overtube end tip due to external forces using only auxiliary tendons in the optimized path without additional mechanical structures. Overall, the proposed method involved moving the overtube to the target lesion through the main driving tendon and applying tension to the auxiliary tendons to reinforce the structural stiffness. The complete system was analyzed in terms of energy, and the sigmoidal auxiliary tendons were verified to effectively reinforce the structural stiffness of the overtube consisting of rolling joints. In addition, the design guidelines of the overtube for actual endoscopic surgery were proposed considering hollowness, retroflexion, and high structural stiffness. The positional changes due to external forces were confirmed to be reduced by 60% over the entire workspace.</p>","PeriodicalId":48685,"journal":{"name":"Soft Robotics","volume":"10 2","pages":"234-245"},"PeriodicalIF":6.4000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Sigmoidal Auxiliary Tendon-Driven Mechanism Reinforcing Structural Stiffness of Hyper-Redundant Manipulator for Endoscopic Surgery.\",\"authors\":\"Hansoul Kim, Jae Min You, Minho Hwang, Ki-Uk Kyung, Dong-Soo Kwon\",\"doi\":\"10.1089/soro.2021.0148\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The overtube of an endoscopic surgery robot is fixed when performing tasks, unlike those of commercial endoscopes, and this overtube should have high structural stiffness after reaching the target lesion so that sufficient tension can be applied to the lesion tissue with the surgical tool and there are fewer changes in the field of view of the endoscopic camera from this reaction force. Various methods have been proposed to reinforce the structural stiffnesses of hyper-redundant manipulators. However, the safety, rapid response, space efficiency, and cost-effectiveness of these methods should be considered for use in actual clinical environments, such as the gastrointestinal tract. This study proposed a method to minimize the positional changes of the overtube end tip due to external forces using only auxiliary tendons in the optimized path without additional mechanical structures. Overall, the proposed method involved moving the overtube to the target lesion through the main driving tendon and applying tension to the auxiliary tendons to reinforce the structural stiffness. The complete system was analyzed in terms of energy, and the sigmoidal auxiliary tendons were verified to effectively reinforce the structural stiffness of the overtube consisting of rolling joints. In addition, the design guidelines of the overtube for actual endoscopic surgery were proposed considering hollowness, retroflexion, and high structural stiffness. The positional changes due to external forces were confirmed to be reduced by 60% over the entire workspace.</p>\",\"PeriodicalId\":48685,\"journal\":{\"name\":\"Soft Robotics\",\"volume\":\"10 2\",\"pages\":\"234-245\"},\"PeriodicalIF\":6.4000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Soft Robotics\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1089/soro.2021.0148\",\"RegionNum\":2,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ROBOTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Soft Robotics","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1089/soro.2021.0148","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ROBOTICS","Score":null,"Total":0}
Sigmoidal Auxiliary Tendon-Driven Mechanism Reinforcing Structural Stiffness of Hyper-Redundant Manipulator for Endoscopic Surgery.
The overtube of an endoscopic surgery robot is fixed when performing tasks, unlike those of commercial endoscopes, and this overtube should have high structural stiffness after reaching the target lesion so that sufficient tension can be applied to the lesion tissue with the surgical tool and there are fewer changes in the field of view of the endoscopic camera from this reaction force. Various methods have been proposed to reinforce the structural stiffnesses of hyper-redundant manipulators. However, the safety, rapid response, space efficiency, and cost-effectiveness of these methods should be considered for use in actual clinical environments, such as the gastrointestinal tract. This study proposed a method to minimize the positional changes of the overtube end tip due to external forces using only auxiliary tendons in the optimized path without additional mechanical structures. Overall, the proposed method involved moving the overtube to the target lesion through the main driving tendon and applying tension to the auxiliary tendons to reinforce the structural stiffness. The complete system was analyzed in terms of energy, and the sigmoidal auxiliary tendons were verified to effectively reinforce the structural stiffness of the overtube consisting of rolling joints. In addition, the design guidelines of the overtube for actual endoscopic surgery were proposed considering hollowness, retroflexion, and high structural stiffness. The positional changes due to external forces were confirmed to be reduced by 60% over the entire workspace.
期刊介绍:
Soft Robotics (SoRo) stands as a premier robotics journal, showcasing top-tier, peer-reviewed research on the forefront of soft and deformable robotics. Encompassing flexible electronics, materials science, computer science, and biomechanics, it pioneers breakthroughs in robotic technology capable of safe interaction with living systems and navigating complex environments, natural or human-made.
With a multidisciplinary approach, SoRo integrates advancements in biomedical engineering, biomechanics, mathematical modeling, biopolymer chemistry, computer science, and tissue engineering, offering comprehensive insights into constructing adaptable devices that can undergo significant changes in shape and size. This transformative technology finds critical applications in surgery, assistive healthcare devices, emergency search and rescue, space instrument repair, mine detection, and beyond.