MAXPEEM: MAX IV实验室的光谱显微镜光束线。

IF 2.4 3区 物理与天体物理 Q2 INSTRUMENTS & INSTRUMENTATION Journal of Synchrotron Radiation Pub Date : 2023-03-01 DOI:10.1107/S160057752300019X
Yuran Niu, Nikolay Vinogradov, Alexei Preobrajenski, Claudia Struzzi, Brice Sarpi, Lin Zhu, Evangelos Golias, Alexei Zakharov
{"title":"MAXPEEM: MAX IV实验室的光谱显微镜光束线。","authors":"Yuran Niu,&nbsp;Nikolay Vinogradov,&nbsp;Alexei Preobrajenski,&nbsp;Claudia Struzzi,&nbsp;Brice Sarpi,&nbsp;Lin Zhu,&nbsp;Evangelos Golias,&nbsp;Alexei Zakharov","doi":"10.1107/S160057752300019X","DOIUrl":null,"url":null,"abstract":"<p><p>MAXPEEM, a dedicated photoemission electron microscopy beamline at MAX IV Laboratory, houses a state-of-the-art aberration-corrected spectroscopic photoemission and low-energy electron microscope (AC-SPELEEM). This powerful instrument offers a wide range of complementary techniques providing structural, chemical and magnetic sensitivities with a single-digit nanometre spatial resolution. The beamline can deliver a high photon flux of ≥10<sup>15</sup> photons s<sup>-1</sup> (0.1% bandwidth)<sup>-1</sup> in the range 30-1200 eV with full control of the polarization from an elliptically polarized undulator. The microscope has several features which make it unique from similar instruments. The X-rays from the synchrotron pass through the first beam separator and impinge the surface at normal incidence. The microscope is equipped with an energy analyzer and an aberration corrector which improves both the resolution and the transmission compared with standard microscopes. A new fiber-coupled CMOS camera features an improved modulation transfer function, dynamic range and signal-to-noise ratio compared with the traditional MCP-CCD detection system.</p>","PeriodicalId":17114,"journal":{"name":"Journal of Synchrotron Radiation","volume":"30 Pt 2","pages":"468-478"},"PeriodicalIF":2.4000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000796/pdf/","citationCount":"2","resultStr":"{\"title\":\"MAXPEEM: a spectromicroscopy beamline at MAX IV laboratory.\",\"authors\":\"Yuran Niu,&nbsp;Nikolay Vinogradov,&nbsp;Alexei Preobrajenski,&nbsp;Claudia Struzzi,&nbsp;Brice Sarpi,&nbsp;Lin Zhu,&nbsp;Evangelos Golias,&nbsp;Alexei Zakharov\",\"doi\":\"10.1107/S160057752300019X\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>MAXPEEM, a dedicated photoemission electron microscopy beamline at MAX IV Laboratory, houses a state-of-the-art aberration-corrected spectroscopic photoemission and low-energy electron microscope (AC-SPELEEM). This powerful instrument offers a wide range of complementary techniques providing structural, chemical and magnetic sensitivities with a single-digit nanometre spatial resolution. The beamline can deliver a high photon flux of ≥10<sup>15</sup> photons s<sup>-1</sup> (0.1% bandwidth)<sup>-1</sup> in the range 30-1200 eV with full control of the polarization from an elliptically polarized undulator. The microscope has several features which make it unique from similar instruments. The X-rays from the synchrotron pass through the first beam separator and impinge the surface at normal incidence. The microscope is equipped with an energy analyzer and an aberration corrector which improves both the resolution and the transmission compared with standard microscopes. A new fiber-coupled CMOS camera features an improved modulation transfer function, dynamic range and signal-to-noise ratio compared with the traditional MCP-CCD detection system.</p>\",\"PeriodicalId\":17114,\"journal\":{\"name\":\"Journal of Synchrotron Radiation\",\"volume\":\"30 Pt 2\",\"pages\":\"468-478\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10000796/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Synchrotron Radiation\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1107/S160057752300019X\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S160057752300019X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 2

摘要

MAXPEEM是MAX IV实验室专用的光发射电子显微镜光束线,拥有最先进的像差校正光谱光发射和低能电子显微镜(AC-SPELEEM)。这种强大的仪器提供了广泛的互补技术,提供了一位数纳米空间分辨率的结构,化学和磁灵敏度。该光束线可以在30-1200 eV范围内提供≥1015个光子s-1(0.1%带宽)-1的高光子通量,并且可以完全控制椭圆偏振波动器的偏振。这种显微镜有几个特点,使它在同类仪器中独树一帜。来自同步加速器的x射线通过第一束分离器并以正常入射撞击表面。该显微镜配备了能量分析仪和像差校正器,与标准显微镜相比,提高了分辨率和透射率。与传统的MCP-CCD检测系统相比,新型光纤耦合CMOS相机具有更好的调制传递功能、动态范围和信噪比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
MAXPEEM: a spectromicroscopy beamline at MAX IV laboratory.

MAXPEEM, a dedicated photoemission electron microscopy beamline at MAX IV Laboratory, houses a state-of-the-art aberration-corrected spectroscopic photoemission and low-energy electron microscope (AC-SPELEEM). This powerful instrument offers a wide range of complementary techniques providing structural, chemical and magnetic sensitivities with a single-digit nanometre spatial resolution. The beamline can deliver a high photon flux of ≥1015 photons s-1 (0.1% bandwidth)-1 in the range 30-1200 eV with full control of the polarization from an elliptically polarized undulator. The microscope has several features which make it unique from similar instruments. The X-rays from the synchrotron pass through the first beam separator and impinge the surface at normal incidence. The microscope is equipped with an energy analyzer and an aberration corrector which improves both the resolution and the transmission compared with standard microscopes. A new fiber-coupled CMOS camera features an improved modulation transfer function, dynamic range and signal-to-noise ratio compared with the traditional MCP-CCD detection system.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.00%
发文量
289
审稿时长
4-8 weeks
期刊介绍: Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.
期刊最新文献
Operando double-edge high-resolution X-ray absorption spectroscopy study of BiVO4 photoanodes Development of dual-beamline photoelectron momentum microscopy for valence orbital analysis Measuring magnetic hysteresis curves with polarized soft X-ray resonant reflectivity High-pressure X-ray photon correlation spectroscopy at fourth-generation synchrotron sources Iterative Bragg peak removal on X-ray absorption spectra with automatic intensity correction
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1