有丝分裂指数最大化,对辐射诱导的双中心染色体频率无影响。

IF 2.1 4区 医学 Q2 BIOLOGY International Journal of Radiation Biology Pub Date : 2023-01-01 DOI:10.1080/09553002.2023.2142981
Kai Takebayashi, Keito Echizenya, Yuki Kameya, Daichi Nakajima, Ryo Nakayama, Yohei Fujishima, Valerie Swee Ting Goh, Yu Abe, Kosuke Kasai, Donovan A Anderson, William F Blakely, Tomisato Miura
{"title":"有丝分裂指数最大化,对辐射诱导的双中心染色体频率无影响。","authors":"Kai Takebayashi,&nbsp;Keito Echizenya,&nbsp;Yuki Kameya,&nbsp;Daichi Nakajima,&nbsp;Ryo Nakayama,&nbsp;Yohei Fujishima,&nbsp;Valerie Swee Ting Goh,&nbsp;Yu Abe,&nbsp;Kosuke Kasai,&nbsp;Donovan A Anderson,&nbsp;William F Blakely,&nbsp;Tomisato Miura","doi":"10.1080/09553002.2023.2142981","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The dicentric chromosome (Dic) assay, which is the gold standard for biological dose assessment in radiation emergency medicine, requires an analysis of at least 500 lymphocyte metaphases or 100 Dic aberrations. Therefore, peripheral blood culture conditions able to obtain a high frequency of metaphases for efficient dose evaluation should be optimized. However, the type of blood cultures [i.e. whole blood (WB) or isolated peripheral blood mononuclear cell (PBMC)-culture] and blood volume differ between biodosimetry laboratories. The purpose of this study is to investigate the blood volume at which a high mitotic index (MI) is obtained in peripheral WB-culture and isolated PBMC-culture, and to examine the possible effect of blood volume on radiation-induced Dic frequency.</p><p><strong>Materials and methods: </strong>Peripheral blood was collected from three healthy donors with their informed consent. The complete and differential blood counts were performed using an automated hematology analyzer. After blood count, peripheral blood was irradiated with 0 or 2 Gy X-ray. Blood was cultured with phytohemagglutinin (180 μg/ml) and demecolcine (0.05 μg/ml) for 48 h. The MI and Dic frequency were analyzed in 5, 10, 15, 20, 25, and 30% WB-cultures and 0.6, 1.2, 1.8, 2.4, 3.0, 3.6, and 4.2 ml WB-equivalent PBMC-cultures.</p><p><strong>Results: </strong>In WB-culture, MI showed the highest value (∼22%) in 5-15% WB-culture and then gradually decreased to ∼9% with 30% WB-culture. MI peaked at 36 and 31% in 1.8 and 2.4 ml-WB equivalent volumes for PMBC-cultures, respectively. MI progressively decreased as the amount of PBMCs increased. Although individual differences were observed in the MI values among the three subjects, all the subjects showed the same tendency and higher MI was seen in PBMC than WB-cultures. However, these factors had no significant impact on the yield of Dics. In all culture conditions, the estimated dose calculated based on the Dic frequency was equivalent to the absorbed dose of <i>ex vivo</i> X-ray-irradiated blood.</p><p><strong>Conclusion: </strong>While MI was affected by the blood culture type and the volume of cultured blood, Dic yield did not differ significantly between these conditions. These results could be used by relevant laboratories to optimize MI in certain circumstances.</p>","PeriodicalId":14261,"journal":{"name":"International Journal of Radiation Biology","volume":"99 5","pages":"750-759"},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Mitotic index maximization with no effect on radiation-induced dicentric chromosome frequency.\",\"authors\":\"Kai Takebayashi,&nbsp;Keito Echizenya,&nbsp;Yuki Kameya,&nbsp;Daichi Nakajima,&nbsp;Ryo Nakayama,&nbsp;Yohei Fujishima,&nbsp;Valerie Swee Ting Goh,&nbsp;Yu Abe,&nbsp;Kosuke Kasai,&nbsp;Donovan A Anderson,&nbsp;William F Blakely,&nbsp;Tomisato Miura\",\"doi\":\"10.1080/09553002.2023.2142981\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The dicentric chromosome (Dic) assay, which is the gold standard for biological dose assessment in radiation emergency medicine, requires an analysis of at least 500 lymphocyte metaphases or 100 Dic aberrations. Therefore, peripheral blood culture conditions able to obtain a high frequency of metaphases for efficient dose evaluation should be optimized. However, the type of blood cultures [i.e. whole blood (WB) or isolated peripheral blood mononuclear cell (PBMC)-culture] and blood volume differ between biodosimetry laboratories. The purpose of this study is to investigate the blood volume at which a high mitotic index (MI) is obtained in peripheral WB-culture and isolated PBMC-culture, and to examine the possible effect of blood volume on radiation-induced Dic frequency.</p><p><strong>Materials and methods: </strong>Peripheral blood was collected from three healthy donors with their informed consent. The complete and differential blood counts were performed using an automated hematology analyzer. After blood count, peripheral blood was irradiated with 0 or 2 Gy X-ray. Blood was cultured with phytohemagglutinin (180 μg/ml) and demecolcine (0.05 μg/ml) for 48 h. The MI and Dic frequency were analyzed in 5, 10, 15, 20, 25, and 30% WB-cultures and 0.6, 1.2, 1.8, 2.4, 3.0, 3.6, and 4.2 ml WB-equivalent PBMC-cultures.</p><p><strong>Results: </strong>In WB-culture, MI showed the highest value (∼22%) in 5-15% WB-culture and then gradually decreased to ∼9% with 30% WB-culture. MI peaked at 36 and 31% in 1.8 and 2.4 ml-WB equivalent volumes for PMBC-cultures, respectively. MI progressively decreased as the amount of PBMCs increased. Although individual differences were observed in the MI values among the three subjects, all the subjects showed the same tendency and higher MI was seen in PBMC than WB-cultures. However, these factors had no significant impact on the yield of Dics. In all culture conditions, the estimated dose calculated based on the Dic frequency was equivalent to the absorbed dose of <i>ex vivo</i> X-ray-irradiated blood.</p><p><strong>Conclusion: </strong>While MI was affected by the blood culture type and the volume of cultured blood, Dic yield did not differ significantly between these conditions. These results could be used by relevant laboratories to optimize MI in certain circumstances.</p>\",\"PeriodicalId\":14261,\"journal\":{\"name\":\"International Journal of Radiation Biology\",\"volume\":\"99 5\",\"pages\":\"750-759\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Radiation Biology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/09553002.2023.2142981\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Biology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09553002.2023.2142981","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 2

摘要

目的:双中心染色体(Dic)测定是放射急救医学中生物剂量评估的金标准,需要分析至少500个淋巴细胞中期或100个Dic畸变。因此,应优化能够获得高中期频率的外周血培养条件,以进行有效的剂量评估。然而,血液培养物的类型[即全血(WB)或分离外周血单个核细胞(PBMC)培养物]和血容量在生物剂量测定实验室之间有所不同。本研究的目的是探讨外周血wb培养和离体pbmc培养中获得高有丝分裂指数(MI)的血容量,并探讨血容量对辐射诱导的Dic频率的可能影响。材料与方法:采集3名健康献血者经知情同意的外周血。全自动血液学分析仪进行全血细胞计数和差异血细胞计数。血球计数后,用0或2 Gy x线照射外周血。用植物血凝素(180 μg/ml)和去胆碱(0.05 μg/ml)培养48 h。分析5、10、15、20、25和30% wb -当量培养以及0.6、1.2、1.8、2.4、3.0、3.6和4.2 ml wb -当量pbmc培养的心肌梗死和Dic频率。结果:在wb培养中,MI在5-15% wb培养中最高(约22%),在30% wb培养中逐渐下降至约9%。pmbc培养物的等效体积分别为1.8 ml-WB和2.4 ml-WB时,MI峰值分别为36%和31%。心肌梗死随着pbmc数量的增加而逐渐降低。虽然三个被试之间的MI值存在个体差异,但所有被试都表现出相同的趋势,PBMC的MI值高于wb培养。然而,这些因素对Dics的产率没有显著影响。在所有培养条件下,基于Dic频率计算的估计剂量与体外x射线照射血液的吸收剂量相当。结论:心肌梗死受血培养类型和培养血容量的影响,但心肌梗死产率在不同条件下无显著差异。这些结果可用于相关实验室在某些情况下优化MI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mitotic index maximization with no effect on radiation-induced dicentric chromosome frequency.

Purpose: The dicentric chromosome (Dic) assay, which is the gold standard for biological dose assessment in radiation emergency medicine, requires an analysis of at least 500 lymphocyte metaphases or 100 Dic aberrations. Therefore, peripheral blood culture conditions able to obtain a high frequency of metaphases for efficient dose evaluation should be optimized. However, the type of blood cultures [i.e. whole blood (WB) or isolated peripheral blood mononuclear cell (PBMC)-culture] and blood volume differ between biodosimetry laboratories. The purpose of this study is to investigate the blood volume at which a high mitotic index (MI) is obtained in peripheral WB-culture and isolated PBMC-culture, and to examine the possible effect of blood volume on radiation-induced Dic frequency.

Materials and methods: Peripheral blood was collected from three healthy donors with their informed consent. The complete and differential blood counts were performed using an automated hematology analyzer. After blood count, peripheral blood was irradiated with 0 or 2 Gy X-ray. Blood was cultured with phytohemagglutinin (180 μg/ml) and demecolcine (0.05 μg/ml) for 48 h. The MI and Dic frequency were analyzed in 5, 10, 15, 20, 25, and 30% WB-cultures and 0.6, 1.2, 1.8, 2.4, 3.0, 3.6, and 4.2 ml WB-equivalent PBMC-cultures.

Results: In WB-culture, MI showed the highest value (∼22%) in 5-15% WB-culture and then gradually decreased to ∼9% with 30% WB-culture. MI peaked at 36 and 31% in 1.8 and 2.4 ml-WB equivalent volumes for PMBC-cultures, respectively. MI progressively decreased as the amount of PBMCs increased. Although individual differences were observed in the MI values among the three subjects, all the subjects showed the same tendency and higher MI was seen in PBMC than WB-cultures. However, these factors had no significant impact on the yield of Dics. In all culture conditions, the estimated dose calculated based on the Dic frequency was equivalent to the absorbed dose of ex vivo X-ray-irradiated blood.

Conclusion: While MI was affected by the blood culture type and the volume of cultured blood, Dic yield did not differ significantly between these conditions. These results could be used by relevant laboratories to optimize MI in certain circumstances.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.00
自引率
11.50%
发文量
142
审稿时长
3 months
期刊介绍: The International Journal of Radiation Biology publishes original papers, reviews, current topic articles, technical notes/reports, and meeting reports on the effects of ionizing, UV and visible radiation, accelerated particles, electromagnetic fields, ultrasound, heat and related modalities. The focus is on the biological effects of such radiations: from radiation chemistry to the spectrum of responses of living organisms and underlying mechanisms, including genetic abnormalities, repair phenomena, cell death, dose modifying agents and tissue responses. Application of basic studies to medical uses of radiation extends the coverage to practical problems such as physical and chemical adjuvants which improve the effectiveness of radiation in cancer therapy. Assessment of the hazards of low doses of radiation is also considered.
期刊最新文献
Value of 18F-FDG PET/CT-based radiomics features for differentiating primary lung cancer and solitary lung metastasis in patients with colorectal adenocarcinoma. Differential biological effect of low doses of ionizing radiation depending on the radiosensitivity in a cell line model Long-term biological effects after acute 131I-administration of two rat models (with and without thyroid). The elicitation effects of diode and He-Ne laser irradiations on the alleviation of nutrient-deficiency induced damage in anthocyanin-producing red-fleshed apple cell suspension. Gamma-rays induced genome wide stable mutations in cowpea deciphered through whole genome sequencing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1