Terri Call, Andrew D Pucker, Gerald McGwin, Quentin X Franklin, Amy Logan
{"title":"每月更换隐形眼镜佩戴者的实时眼部舒适度报告。","authors":"Terri Call, Andrew D Pucker, Gerald McGwin, Quentin X Franklin, Amy Logan","doi":"10.2147/OPTO.S403319","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To map contact lens (CL) comfort over the full wear day and across 1 month's wear in established, asymptomatic to minimally symptomatic, reusable, soft CL wearers.</p><p><strong>Methods: </strong>Adult, 18- to 45-year-old, participants were recruited and required to have 20/20 best-corrected visual acuity or better and must have been asymptomatic to minimally symptomatic CL wearers. Participants were required to be able to wear TOTAL30® sphere CLs and have minimal astigmatism. Participants were fit in the study CLs and asked to wear these CLs daily for the next month for 16 hours per day each day. Participants were asked to complete a visual analog scale (VAS) survey via text message at time of CL application and after 8, 10, 12, 14, and 16 hours of wear and at CL removal on days 1, 2, 3, 4, and 5 and at 2 weeks and 1 month. The utilized VAS had a ±50 scale with positive scores being comfortable, negative scores being uncomfortable, and scores of 0 being neutral comfort.</p><p><strong>Results: </strong>Forty-eight participants were recruited who had a mean ± SD age of 26.2 ± 5.2 years (71% female). Mean initial VAS CL comfort scores at initial CL dispense were 45.56 ± 9.20 units. Mean CL wear times for any of the days evaluated were at least 14.80 ± 2.41 hours per day and did not differ across the study (p = 0.77). Mean comfort VAS scores significantly decreased over the wear day (all days p ≤ 0.02), yet there were no significant differences in VAS comfort scores across the same time of day for the duration of the study (all times p ≥ 0.06).</p><p><strong>Conclusion: </strong>This study determined that while CL wearers were slightly less comfortable at the end of the day compared to application, this comfort change was minimal given that the average participants had overwhelmingly good comfort at all time-points evaluated. Comfort scores were likewise consistent across 1 month of wear.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":"15 ","pages":"97-103"},"PeriodicalIF":1.4000,"publicationDate":"2023-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0f/7d/opto-15-97.PMC10167961.pdf","citationCount":"0","resultStr":"{\"title\":\"Real-Time Ocular Comfort Reporting in Monthly Replacement Contact Lens Wearers.\",\"authors\":\"Terri Call, Andrew D Pucker, Gerald McGwin, Quentin X Franklin, Amy Logan\",\"doi\":\"10.2147/OPTO.S403319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To map contact lens (CL) comfort over the full wear day and across 1 month's wear in established, asymptomatic to minimally symptomatic, reusable, soft CL wearers.</p><p><strong>Methods: </strong>Adult, 18- to 45-year-old, participants were recruited and required to have 20/20 best-corrected visual acuity or better and must have been asymptomatic to minimally symptomatic CL wearers. Participants were required to be able to wear TOTAL30® sphere CLs and have minimal astigmatism. Participants were fit in the study CLs and asked to wear these CLs daily for the next month for 16 hours per day each day. Participants were asked to complete a visual analog scale (VAS) survey via text message at time of CL application and after 8, 10, 12, 14, and 16 hours of wear and at CL removal on days 1, 2, 3, 4, and 5 and at 2 weeks and 1 month. The utilized VAS had a ±50 scale with positive scores being comfortable, negative scores being uncomfortable, and scores of 0 being neutral comfort.</p><p><strong>Results: </strong>Forty-eight participants were recruited who had a mean ± SD age of 26.2 ± 5.2 years (71% female). Mean initial VAS CL comfort scores at initial CL dispense were 45.56 ± 9.20 units. Mean CL wear times for any of the days evaluated were at least 14.80 ± 2.41 hours per day and did not differ across the study (p = 0.77). Mean comfort VAS scores significantly decreased over the wear day (all days p ≤ 0.02), yet there were no significant differences in VAS comfort scores across the same time of day for the duration of the study (all times p ≥ 0.06).</p><p><strong>Conclusion: </strong>This study determined that while CL wearers were slightly less comfortable at the end of the day compared to application, this comfort change was minimal given that the average participants had overwhelmingly good comfort at all time-points evaluated. Comfort scores were likewise consistent across 1 month of wear.</p>\",\"PeriodicalId\":43701,\"journal\":{\"name\":\"Clinical Optometry\",\"volume\":\"15 \",\"pages\":\"97-103\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0f/7d/opto-15-97.PMC10167961.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Optometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTO.S403319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S403319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Real-Time Ocular Comfort Reporting in Monthly Replacement Contact Lens Wearers.
Purpose: To map contact lens (CL) comfort over the full wear day and across 1 month's wear in established, asymptomatic to minimally symptomatic, reusable, soft CL wearers.
Methods: Adult, 18- to 45-year-old, participants were recruited and required to have 20/20 best-corrected visual acuity or better and must have been asymptomatic to minimally symptomatic CL wearers. Participants were required to be able to wear TOTAL30® sphere CLs and have minimal astigmatism. Participants were fit in the study CLs and asked to wear these CLs daily for the next month for 16 hours per day each day. Participants were asked to complete a visual analog scale (VAS) survey via text message at time of CL application and after 8, 10, 12, 14, and 16 hours of wear and at CL removal on days 1, 2, 3, 4, and 5 and at 2 weeks and 1 month. The utilized VAS had a ±50 scale with positive scores being comfortable, negative scores being uncomfortable, and scores of 0 being neutral comfort.
Results: Forty-eight participants were recruited who had a mean ± SD age of 26.2 ± 5.2 years (71% female). Mean initial VAS CL comfort scores at initial CL dispense were 45.56 ± 9.20 units. Mean CL wear times for any of the days evaluated were at least 14.80 ± 2.41 hours per day and did not differ across the study (p = 0.77). Mean comfort VAS scores significantly decreased over the wear day (all days p ≤ 0.02), yet there were no significant differences in VAS comfort scores across the same time of day for the duration of the study (all times p ≥ 0.06).
Conclusion: This study determined that while CL wearers were slightly less comfortable at the end of the day compared to application, this comfort change was minimal given that the average participants had overwhelmingly good comfort at all time-points evaluated. Comfort scores were likewise consistent across 1 month of wear.
期刊介绍:
Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.