{"title":"电除尘器中电极框屏蔽作用的研究。","authors":"Haibao Zhao,&nbsp;Gang Yang,&nbsp;Jiadong Shen,&nbsp;Baiqian Liu,&nbsp;Ziqiang Lyu","doi":"10.1080/10962247.2023.2200402","DOIUrl":null,"url":null,"abstract":"<p><p>The electrostatic precipitator (ESP) plays an important role in the dust removal from the flue gas. Currently, the shielding effect of electrode frames seriously affects the electric field distribution and dust removal efficiency of ESPs. In order to explore the shielding effect and propose an improved measurement, an experimental setup with RS barbed electrodes and a 480 C type dust collector electrode plate was built to evaluate the corona discharge characteristics. The current density distribution on the surface of the collecting plate was tested on an ESP experimental setup. The effect of electrode frames on the current density distribution was also systematically investigated. The test results show that the current density distribution on the position that directly opposites the needle of RS corona discharge is much higher, on the contrary, the current density on the position that directly opposites the frames is almost zero. It indicates that the frames have a shielding effect on the corona discharge. Therefore, the dust collection efficiency is low in actual ESPs due to the dust escape route caused by the shielding effect. To solve the problem, a new ESP with a split-level frame arrangement was proposed.<i>Implications:</i> The conventional electrostatic precipitators are often affected by the electrostatic shielding effect, which leads to uneven charging. The particulate removal efficiency decreases and escape channels are very easy to form. In this study, effective measures were proposed to solve the electrostatic shielding of dust collector frames by studying their electrostatic shielding mechanism. The study provides theoretical support for the improvement of electrostatic precipitators, while improving the dust removal efficiency.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research on the shielding effect of the electrode frames in the electrostatic precipitator.\",\"authors\":\"Haibao Zhao,&nbsp;Gang Yang,&nbsp;Jiadong Shen,&nbsp;Baiqian Liu,&nbsp;Ziqiang Lyu\",\"doi\":\"10.1080/10962247.2023.2200402\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The electrostatic precipitator (ESP) plays an important role in the dust removal from the flue gas. Currently, the shielding effect of electrode frames seriously affects the electric field distribution and dust removal efficiency of ESPs. In order to explore the shielding effect and propose an improved measurement, an experimental setup with RS barbed electrodes and a 480 C type dust collector electrode plate was built to evaluate the corona discharge characteristics. The current density distribution on the surface of the collecting plate was tested on an ESP experimental setup. The effect of electrode frames on the current density distribution was also systematically investigated. The test results show that the current density distribution on the position that directly opposites the needle of RS corona discharge is much higher, on the contrary, the current density on the position that directly opposites the frames is almost zero. It indicates that the frames have a shielding effect on the corona discharge. Therefore, the dust collection efficiency is low in actual ESPs due to the dust escape route caused by the shielding effect. To solve the problem, a new ESP with a split-level frame arrangement was proposed.<i>Implications:</i> The conventional electrostatic precipitators are often affected by the electrostatic shielding effect, which leads to uneven charging. The particulate removal efficiency decreases and escape channels are very easy to form. In this study, effective measures were proposed to solve the electrostatic shielding of dust collector frames by studying their electrostatic shielding mechanism. The study provides theoretical support for the improvement of electrostatic precipitators, while improving the dust removal efficiency.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1080/10962247.2023.2200402\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/10962247.2023.2200402","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 1

摘要

电除尘器在烟气除尘中起着重要的作用。目前,电极框架的屏蔽效应严重影响了静电除尘器的电场分布和除尘效率。为了探索其屏蔽效果并提出改进的测量方法,建立了RS倒刺电极和480 C型集尘极板的实验装置,对其电晕放电特性进行了评价。在电除尘器实验装置上测试了集热器表面的电流密度分布。系统地研究了电极框架对电流密度分布的影响。试验结果表明,RS电晕放电针正对面位置的电流密度分布要高得多,相反,机架正对面位置的电流密度几乎为零。结果表明,框架对电晕放电具有屏蔽作用。因此,由于屏蔽效应造成的粉尘逸出路线,实际esp的集尘效率较低。为了解决这一问题,提出了一种分层框架结构的ESP。启示:传统的静电除尘器经常受到静电屏蔽效应的影响,导致充电不均匀。颗粒去除效率降低,极易形成逃逸通道。本研究通过对除尘器框架静电屏蔽机理的研究,提出了解决除尘器框架静电屏蔽的有效措施。该研究为改进静电除尘器提供了理论支持,同时提高了除尘效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Research on the shielding effect of the electrode frames in the electrostatic precipitator.

The electrostatic precipitator (ESP) plays an important role in the dust removal from the flue gas. Currently, the shielding effect of electrode frames seriously affects the electric field distribution and dust removal efficiency of ESPs. In order to explore the shielding effect and propose an improved measurement, an experimental setup with RS barbed electrodes and a 480 C type dust collector electrode plate was built to evaluate the corona discharge characteristics. The current density distribution on the surface of the collecting plate was tested on an ESP experimental setup. The effect of electrode frames on the current density distribution was also systematically investigated. The test results show that the current density distribution on the position that directly opposites the needle of RS corona discharge is much higher, on the contrary, the current density on the position that directly opposites the frames is almost zero. It indicates that the frames have a shielding effect on the corona discharge. Therefore, the dust collection efficiency is low in actual ESPs due to the dust escape route caused by the shielding effect. To solve the problem, a new ESP with a split-level frame arrangement was proposed.Implications: The conventional electrostatic precipitators are often affected by the electrostatic shielding effect, which leads to uneven charging. The particulate removal efficiency decreases and escape channels are very easy to form. In this study, effective measures were proposed to solve the electrostatic shielding of dust collector frames by studying their electrostatic shielding mechanism. The study provides theoretical support for the improvement of electrostatic precipitators, while improving the dust removal efficiency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1