{"title":"准确可靠的胫骨加速度测量的最小采样频率。","authors":"Kevin G Aubol, Clare E Milner","doi":"10.1123/jab.2022-0069","DOIUrl":null,"url":null,"abstract":"<p><p>Field-based tibial acceleration measurements are increasingly common but sampling frequencies vary between accelerometers. The purpose of this study was to determine the minimum sampling frequency needed for reliable and accurate measurement of peak axial and resultant tibial acceleration during running in the field. Tibial acceleration was measured at 7161 Hz in 19 healthy runners on concrete and grass. Acceleration data were down sampled to approximate previously used sampling frequencies. Peak axial and resultant tibial acceleration were calculated for each sampling frequency. The within-session reliability and accuracy of peak axial and resultant tibial accelerations were evaluated using intraclass correlation coefficients, mean differences, and 95% limits of agreements. Intraclass correlation coefficients greater than .9 indicated excellent within-session reliability for both peak axial and resultant tibial acceleration measured while running on concrete and grass. Peak axial and resultant tibial accelerations were 0.5 to 1.4 g lower and minimal detectable differences were up to 0.6 g higher at 102 Hz compared with higher sampling frequencies. We recommend a minimum sampling frequency of 199 Hz for accurate and reliable measurements of peak axial and resultant tibial acceleration in the field.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"39 3","pages":"193-198"},"PeriodicalIF":1.1000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Minimum Sampling Frequency for Accurate and Reliable Tibial Acceleration Measurements During Rearfoot Strike Running in the Field.\",\"authors\":\"Kevin G Aubol, Clare E Milner\",\"doi\":\"10.1123/jab.2022-0069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Field-based tibial acceleration measurements are increasingly common but sampling frequencies vary between accelerometers. The purpose of this study was to determine the minimum sampling frequency needed for reliable and accurate measurement of peak axial and resultant tibial acceleration during running in the field. Tibial acceleration was measured at 7161 Hz in 19 healthy runners on concrete and grass. Acceleration data were down sampled to approximate previously used sampling frequencies. Peak axial and resultant tibial acceleration were calculated for each sampling frequency. The within-session reliability and accuracy of peak axial and resultant tibial accelerations were evaluated using intraclass correlation coefficients, mean differences, and 95% limits of agreements. Intraclass correlation coefficients greater than .9 indicated excellent within-session reliability for both peak axial and resultant tibial acceleration measured while running on concrete and grass. Peak axial and resultant tibial accelerations were 0.5 to 1.4 g lower and minimal detectable differences were up to 0.6 g higher at 102 Hz compared with higher sampling frequencies. We recommend a minimum sampling frequency of 199 Hz for accurate and reliable measurements of peak axial and resultant tibial acceleration in the field.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":\"39 3\",\"pages\":\"193-198\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2022-0069\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0069","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Minimum Sampling Frequency for Accurate and Reliable Tibial Acceleration Measurements During Rearfoot Strike Running in the Field.
Field-based tibial acceleration measurements are increasingly common but sampling frequencies vary between accelerometers. The purpose of this study was to determine the minimum sampling frequency needed for reliable and accurate measurement of peak axial and resultant tibial acceleration during running in the field. Tibial acceleration was measured at 7161 Hz in 19 healthy runners on concrete and grass. Acceleration data were down sampled to approximate previously used sampling frequencies. Peak axial and resultant tibial acceleration were calculated for each sampling frequency. The within-session reliability and accuracy of peak axial and resultant tibial accelerations were evaluated using intraclass correlation coefficients, mean differences, and 95% limits of agreements. Intraclass correlation coefficients greater than .9 indicated excellent within-session reliability for both peak axial and resultant tibial acceleration measured while running on concrete and grass. Peak axial and resultant tibial accelerations were 0.5 to 1.4 g lower and minimal detectable differences were up to 0.6 g higher at 102 Hz compared with higher sampling frequencies. We recommend a minimum sampling frequency of 199 Hz for accurate and reliable measurements of peak axial and resultant tibial acceleration in the field.
期刊介绍:
The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.