Liliane C Roosendaal, Willemijn van den Ancker, Arno M Wiersema, Jan D Blankensteijn, Vincent Jongkind
{"title":"非心脏动脉手术中未分离的肝素和活化凝血时间。","authors":"Liliane C Roosendaal, Willemijn van den Ancker, Arno M Wiersema, Jan D Blankensteijn, Vincent Jongkind","doi":"10.23736/S0021-9509.23.12723-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Unfractionated heparin is administered during non-cardiac arterial procedures (NCAP) to prevent thromboembolic complications. In order to achieve a safe level of anticoagulation, the effect of heparin can be measured. The aim of this review was to provide an overview on what is known about heparin, suggested tests to monitor the effect of heparin, including the activated clotting time (ACT), and the factors that could influence that ACT.</p><p><strong>Evidence acquisition: </strong>A literature search in PubMed was performed. Articles reporting on heparin, clotting time tests (including thrombin time, activated partial thromboplastin time, anti-activated factor X and ACT), and ACT measurement devices were selected.</p><p><strong>Evidence synthesis: </strong>Heparin has a non-predictable effect in the individual patient, which could be measured using the ACT. However, ACT values can be influenced by many factors, such as hemodilution, hypothermia and thrombocytopenia. In addition, a high variation in ACT outcomes is found between measurement devices of different brands. In the sparse literature on the role of ACT during NCAP, no consensus has been reached on optimal target ACT values. An ACT >250 seconds leads to more bleeding complications. Females have a longer ACT after heparin administration, with a higher risk of bleeding complications.</p><p><strong>Conclusions: </strong>The effect of heparin is unpredictable. ACT can be used to monitor the effect of heparin and achieve individualized anticoagulation, tailored to the patient and the specifics of the operative procedure. However, the ACT itself can be affected by several factors and caution must be present, as measured ACT values differ between measurement devices.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unfractionated heparin and the activated clotting time in non-cardiac arterial procedures.\",\"authors\":\"Liliane C Roosendaal, Willemijn van den Ancker, Arno M Wiersema, Jan D Blankensteijn, Vincent Jongkind\",\"doi\":\"10.23736/S0021-9509.23.12723-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Unfractionated heparin is administered during non-cardiac arterial procedures (NCAP) to prevent thromboembolic complications. In order to achieve a safe level of anticoagulation, the effect of heparin can be measured. The aim of this review was to provide an overview on what is known about heparin, suggested tests to monitor the effect of heparin, including the activated clotting time (ACT), and the factors that could influence that ACT.</p><p><strong>Evidence acquisition: </strong>A literature search in PubMed was performed. Articles reporting on heparin, clotting time tests (including thrombin time, activated partial thromboplastin time, anti-activated factor X and ACT), and ACT measurement devices were selected.</p><p><strong>Evidence synthesis: </strong>Heparin has a non-predictable effect in the individual patient, which could be measured using the ACT. However, ACT values can be influenced by many factors, such as hemodilution, hypothermia and thrombocytopenia. In addition, a high variation in ACT outcomes is found between measurement devices of different brands. In the sparse literature on the role of ACT during NCAP, no consensus has been reached on optimal target ACT values. An ACT >250 seconds leads to more bleeding complications. Females have a longer ACT after heparin administration, with a higher risk of bleeding complications.</p><p><strong>Conclusions: </strong>The effect of heparin is unpredictable. ACT can be used to monitor the effect of heparin and achieve individualized anticoagulation, tailored to the patient and the specifics of the operative procedure. However, the ACT itself can be affected by several factors and caution must be present, as measured ACT values differ between measurement devices.</p>\",\"PeriodicalId\":50245,\"journal\":{\"name\":\"Journal of Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S0021-9509.23.12723-6\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.23.12723-6","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Unfractionated heparin and the activated clotting time in non-cardiac arterial procedures.
Introduction: Unfractionated heparin is administered during non-cardiac arterial procedures (NCAP) to prevent thromboembolic complications. In order to achieve a safe level of anticoagulation, the effect of heparin can be measured. The aim of this review was to provide an overview on what is known about heparin, suggested tests to monitor the effect of heparin, including the activated clotting time (ACT), and the factors that could influence that ACT.
Evidence acquisition: A literature search in PubMed was performed. Articles reporting on heparin, clotting time tests (including thrombin time, activated partial thromboplastin time, anti-activated factor X and ACT), and ACT measurement devices were selected.
Evidence synthesis: Heparin has a non-predictable effect in the individual patient, which could be measured using the ACT. However, ACT values can be influenced by many factors, such as hemodilution, hypothermia and thrombocytopenia. In addition, a high variation in ACT outcomes is found between measurement devices of different brands. In the sparse literature on the role of ACT during NCAP, no consensus has been reached on optimal target ACT values. An ACT >250 seconds leads to more bleeding complications. Females have a longer ACT after heparin administration, with a higher risk of bleeding complications.
Conclusions: The effect of heparin is unpredictable. ACT can be used to monitor the effect of heparin and achieve individualized anticoagulation, tailored to the patient and the specifics of the operative procedure. However, the ACT itself can be affected by several factors and caution must be present, as measured ACT values differ between measurement devices.
期刊介绍:
The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.