经导管主动脉瓣置换术后新发传导障碍对预后的影响:一项单中心研究

IF 1.6 3区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of interventional cardiology Pub Date : 2023-01-01 DOI:10.1155/2023/5390338
Claudia See, Yanting Wang, Haocheng Huang, Helen Parise, Yiping Yang, Daniela Tirziu, Dominic P Francese, Nikolaos Papoutsidakis, Eric Bader, Ryan K Kaple, Michael Cleman, Alexandra J Lansky, John K Forrest
{"title":"经导管主动脉瓣置换术后新发传导障碍对预后的影响:一项单中心研究","authors":"Claudia See,&nbsp;Yanting Wang,&nbsp;Haocheng Huang,&nbsp;Helen Parise,&nbsp;Yiping Yang,&nbsp;Daniela Tirziu,&nbsp;Dominic P Francese,&nbsp;Nikolaos Papoutsidakis,&nbsp;Eric Bader,&nbsp;Ryan K Kaple,&nbsp;Michael Cleman,&nbsp;Alexandra J Lansky,&nbsp;John K Forrest","doi":"10.1155/2023/5390338","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data on the impact and duration of these conduction disturbances on longer term outcomes.</p><p><strong>Objective: </strong>To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes.</p><p><strong>Methods: </strong>This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death.</p><p><strong>Results: </strong>Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, <i>p</i> < 0.001) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, <i>p</i>=0.044 and HR 1.90, <i>p</i>=0.046, respectively).</p><p><strong>Conclusion: </strong>Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.</p>","PeriodicalId":16329,"journal":{"name":"Journal of interventional cardiology","volume":"2023 ","pages":"5390338"},"PeriodicalIF":1.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10247319/pdf/","citationCount":"1","resultStr":"{\"title\":\"Impact of New-Onset Conduction Disturbances following Transcatheter Aortic Valve Replacement on Outcomes: A Single-Center Study.\",\"authors\":\"Claudia See,&nbsp;Yanting Wang,&nbsp;Haocheng Huang,&nbsp;Helen Parise,&nbsp;Yiping Yang,&nbsp;Daniela Tirziu,&nbsp;Dominic P Francese,&nbsp;Nikolaos Papoutsidakis,&nbsp;Eric Bader,&nbsp;Ryan K Kaple,&nbsp;Michael Cleman,&nbsp;Alexandra J Lansky,&nbsp;John K Forrest\",\"doi\":\"10.1155/2023/5390338\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data on the impact and duration of these conduction disturbances on longer term outcomes.</p><p><strong>Objective: </strong>To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes.</p><p><strong>Methods: </strong>This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death.</p><p><strong>Results: </strong>Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, <i>p</i> < 0.001) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, <i>p</i>=0.044 and HR 1.90, <i>p</i>=0.046, respectively).</p><p><strong>Conclusion: </strong>Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.</p>\",\"PeriodicalId\":16329,\"journal\":{\"name\":\"Journal of interventional cardiology\",\"volume\":\"2023 \",\"pages\":\"5390338\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10247319/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of interventional cardiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/5390338\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of interventional cardiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/5390338","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 1

摘要

背景:经导管主动脉瓣置换术(TAVR)与外科主动脉瓣置换术相比,已知会增加传导障碍的发生率;然而,关于这些传导干扰对长期结果的影响和持续时间的数据有限。目的:确定持续性和非持续性新发传导障碍对tavr相关并发症和结局的不同影响。方法:对2012年7月至2019年8月在耶鲁大学纽黑文医院连续接受TAVR治疗的927例主动脉瓣狭窄患者进行单中心回顾性分析。本研究选择TAVR后7天内新发传导障碍的患者。持续性和非持续性干扰分别定义为TAVR后1.5年或死亡期间所有患者心电图持续或不持续。结果:TAVR术后7 d内,42.3%(392/927)患者出现传导障碍。传导障碍在150例(38%)患者中持续存在,187例(48%)患者未持续存在,55例(14%)患者因混合(持续性和非持续性)障碍而被排除。与非持续性精神障碍患者相比,持续性精神障碍患者更有可能在TAVR手术后7天内接受PPM(46.0%对4.3%,p < 0.001),并且具有更高的未经调整的1年心脏相关和全因死亡风险(HR 2.54, p=0.044和HR 1.90, p=0.046)。结论:持续的传导障碍与TAVR术后一年较高的心脏死亡率和全因死亡率相关。未来的研究应探讨手术周围的因素,以减少持续的传导障碍和超过一年的随访结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of New-Onset Conduction Disturbances following Transcatheter Aortic Valve Replacement on Outcomes: A Single-Center Study.

Background: Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data on the impact and duration of these conduction disturbances on longer term outcomes.

Objective: To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes.

Methods: This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death.

Results: Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, p < 0.001) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, p=0.044 and HR 1.90, p=0.046, respectively).

Conclusion: Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of interventional cardiology
Journal of interventional cardiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.80
自引率
0.00%
发文量
81
审稿时长
6-12 weeks
期刊介绍: Journal of Interventional Cardiology is a peer-reviewed, Open Access journal that provides a forum for cardiologists determined to stay current in the diagnosis, investigation, and management of patients with cardiovascular disease and its associated complications. The journal publishes original research articles, review articles, and clinical studies focusing on new procedures and techniques in all major subject areas in the field, including: Acute coronary syndrome Coronary disease Congenital heart diseases Myocardial infarction Peripheral arterial disease Valvular heart disease Cardiac hemodynamics and physiology Haemostasis and thrombosis
期刊最新文献
Epidemiological Trends, Etiology, and Burden Study of Heart Failure in China, 1990–2019 A Comparative Analysis of Primary and Bailout ADR in CTO-PCI The Effect of Electromagnetic Interference Produced by Smartphones Using 5G Network on Patients With Permanent Pacemakers (EMS5G-PPM Study) Comparison of Sheathless and Sheathed Guiding Catheters in Transradial Percutaneous Coronary Interventions: A Systematic Review and Meta-Analysis Percutaneous Coronary Intervention Using the DynamX Sirolimus-Eluting Bioadaptor: 12-Month Clinical and Imaging Outcomes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1