新一代钛合金表面改性的现代方法。

IF 0.8 4区 医学 Q4 BIOPHYSICS Acta of bioengineering and biomechanics Pub Date : 2022-01-01
Julia Lisoń-Kubica, Anna Taratuta, Karolina Goldsztajn, Magdalena Antonowicz, Witold Walke, Aneta Dyner, Marcin Basiaga
{"title":"新一代钛合金表面改性的现代方法。","authors":"Julia Lisoń-Kubica,&nbsp;Anna Taratuta,&nbsp;Karolina Goldsztajn,&nbsp;Magdalena Antonowicz,&nbsp;Witold Walke,&nbsp;Aneta Dyner,&nbsp;Marcin Basiaga","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The constantly growing need for the use of implants in osteotomy is mainly due to the aging population and the need for long-term use of this type of biomaterials. Improving implant materials requires the selection of appropriate functional properties. Currently used titanium (Ti) alloys, such as Ti6Al4V and Ti6Al7Nb, are being replaced by materials with better biocompatibility, such as vanadium (V) or niobium (Nb), allowing for creation of the so-called new generation alloys. These new alloys, with the incorporation of zirconium (Zr), iron, and tantalum, possess Young's modulus close to that of a bone, which further improves the improves the biomaterial's. biocompatibility. This article describes the atomic layer deposition (ALD) method and its possible applications in the new generation of titanium alloys for biomedical applications. Also, the exemplary results of tin oxide (SnO2) thin coatings deposited by ALD and physical vapor deposition (PVD) methods are presented. This study aimed to evaluate the physicochemical properties of a Ti13Nb13Zr alloy used for elements in the skeletal system. As the temperature and the number of cycles vary, the results demonstrate that the surface area of the samples changes. The uncoated Ti13Nb13Zr alloy exhibits hydrophilic properties. However, all coated specimens improve in this respect and provide improved clinical results. after the applied modification, the samples have a smaller contact angle, but still remain in the range of 0-90°, which makes it possible to conclude that their nature remains hydrophilic. Coating the specimens decreased the mineralization risk of postoperative complications. As a result, the biomaterials demonstrated improved effectiveness, decreased complication indicators, and improved patient well-being.</p>","PeriodicalId":6897,"journal":{"name":"Acta of bioengineering and biomechanics","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modern methods of surface modification for new-generation titanium alloys.\",\"authors\":\"Julia Lisoń-Kubica,&nbsp;Anna Taratuta,&nbsp;Karolina Goldsztajn,&nbsp;Magdalena Antonowicz,&nbsp;Witold Walke,&nbsp;Aneta Dyner,&nbsp;Marcin Basiaga\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The constantly growing need for the use of implants in osteotomy is mainly due to the aging population and the need for long-term use of this type of biomaterials. Improving implant materials requires the selection of appropriate functional properties. Currently used titanium (Ti) alloys, such as Ti6Al4V and Ti6Al7Nb, are being replaced by materials with better biocompatibility, such as vanadium (V) or niobium (Nb), allowing for creation of the so-called new generation alloys. These new alloys, with the incorporation of zirconium (Zr), iron, and tantalum, possess Young's modulus close to that of a bone, which further improves the improves the biomaterial's. biocompatibility. This article describes the atomic layer deposition (ALD) method and its possible applications in the new generation of titanium alloys for biomedical applications. Also, the exemplary results of tin oxide (SnO2) thin coatings deposited by ALD and physical vapor deposition (PVD) methods are presented. This study aimed to evaluate the physicochemical properties of a Ti13Nb13Zr alloy used for elements in the skeletal system. As the temperature and the number of cycles vary, the results demonstrate that the surface area of the samples changes. The uncoated Ti13Nb13Zr alloy exhibits hydrophilic properties. However, all coated specimens improve in this respect and provide improved clinical results. after the applied modification, the samples have a smaller contact angle, but still remain in the range of 0-90°, which makes it possible to conclude that their nature remains hydrophilic. Coating the specimens decreased the mineralization risk of postoperative complications. As a result, the biomaterials demonstrated improved effectiveness, decreased complication indicators, and improved patient well-being.</p>\",\"PeriodicalId\":6897,\"journal\":{\"name\":\"Acta of bioengineering and biomechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta of bioengineering and biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta of bioengineering and biomechanics","FirstCategoryId":"5","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

在截骨术中使用植入物的需求不断增长,主要是由于人口老龄化和需要长期使用这类生物材料。改进植入材料需要选择合适的功能特性。目前使用的钛(Ti)合金,如Ti6Al4V和Ti6Al7Nb,正在被具有更好生物相容性的材料所取代,如钒(V)或铌(Nb),允许创造所谓的新一代合金。这些新合金,与锆(Zr),铁和钽的掺入,具有接近骨头的杨氏模量,这进一步提高了生物材料的性能。生物相容性。本文介绍了原子层沉积(ALD)方法及其在新一代生物医用钛合金中的应用前景。此外,还介绍了用ALD和物理气相沉积(PVD)方法沉积氧化锡(SnO2)薄涂层的示例性结果。本研究旨在评估用于骨骼系统元素的Ti13Nb13Zr合金的物理化学性质。结果表明,随着温度和循环次数的变化,样品的表面积发生了变化。未涂覆的Ti13Nb13Zr合金表现出亲水性。然而,所有涂层标本在这方面都有所改善,并提供了更好的临床结果。改性后样品的接触角变小,但仍保持在0-90°范围内,因此可以得出其性质仍保持亲水性的结论。涂层降低了矿化风险的标本术后并发症。结果,生物材料显示出更高的有效性,减少了并发症指标,改善了患者的健康状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modern methods of surface modification for new-generation titanium alloys.

The constantly growing need for the use of implants in osteotomy is mainly due to the aging population and the need for long-term use of this type of biomaterials. Improving implant materials requires the selection of appropriate functional properties. Currently used titanium (Ti) alloys, such as Ti6Al4V and Ti6Al7Nb, are being replaced by materials with better biocompatibility, such as vanadium (V) or niobium (Nb), allowing for creation of the so-called new generation alloys. These new alloys, with the incorporation of zirconium (Zr), iron, and tantalum, possess Young's modulus close to that of a bone, which further improves the improves the biomaterial's. biocompatibility. This article describes the atomic layer deposition (ALD) method and its possible applications in the new generation of titanium alloys for biomedical applications. Also, the exemplary results of tin oxide (SnO2) thin coatings deposited by ALD and physical vapor deposition (PVD) methods are presented. This study aimed to evaluate the physicochemical properties of a Ti13Nb13Zr alloy used for elements in the skeletal system. As the temperature and the number of cycles vary, the results demonstrate that the surface area of the samples changes. The uncoated Ti13Nb13Zr alloy exhibits hydrophilic properties. However, all coated specimens improve in this respect and provide improved clinical results. after the applied modification, the samples have a smaller contact angle, but still remain in the range of 0-90°, which makes it possible to conclude that their nature remains hydrophilic. Coating the specimens decreased the mineralization risk of postoperative complications. As a result, the biomaterials demonstrated improved effectiveness, decreased complication indicators, and improved patient well-being.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta of bioengineering and biomechanics
Acta of bioengineering and biomechanics BIOPHYSICS-ENGINEERING, BIOMEDICAL
CiteScore
2.10
自引率
10.00%
发文量
0
期刊介绍: Acta of Bioengineering and Biomechanics is a platform allowing presentation of investigations results, exchange of ideas and experiences among researchers with technical and medical background. Papers published in Acta of Bioengineering and Biomechanics may cover a wide range of topics in biomechanics, including, but not limited to: Tissue Biomechanics, Orthopedic Biomechanics, Biomaterials, Sport Biomechanics.
期刊最新文献
Characterization of biomaterials with reference to biocompatibility dedicated for patient-specific finger implants Dynamic-passive correction of hallux valgus and associated static foot deformities Quantitative evaluation of stereoscopic augmented reality visualization using an optical see-through head-mounted display Analysis of Muscle Activity During Rowing Stroke Phases Experimental research of energy absorbing structures within helmet samples made with the additive manufacturing method - preliminary study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1