不同深度填充树脂显微硬度的测定。

Analía B Garrofé, Mariana Picca, Andrea E Kaplan
{"title":"不同深度填充树脂显微硬度的测定。","authors":"Analía B Garrofé,&nbsp;Mariana Picca,&nbsp;Andrea E Kaplan","doi":"10.54589/aol.35/1/10","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88);[SDR]t0:27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.</p>","PeriodicalId":7033,"journal":{"name":"Acta odontologica latinoamericana : AOL","volume":"35 1","pages":"10-15"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bd/4b/1852-4834-35-1-10.PMC10283378.pdf","citationCount":"2","resultStr":"{\"title\":\"Determination of microhardness of bulk-fill resins at different depths.\",\"authors\":\"Analía B Garrofé,&nbsp;Mariana Picca,&nbsp;Andrea E Kaplan\",\"doi\":\"10.54589/aol.35/1/10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88);[SDR]t0:27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.</p>\",\"PeriodicalId\":7033,\"journal\":{\"name\":\"Acta odontologica latinoamericana : AOL\",\"volume\":\"35 1\",\"pages\":\"10-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bd/4b/1852-4834-35-1-10.PMC10283378.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta odontologica latinoamericana : AOL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54589/aol.35/1/10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta odontologica latinoamericana : AOL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54589/aol.35/1/10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究的目的是测定不同深度的大块填充树脂的维氏显微硬度(HV)。采用不同的散装填充树脂制备试样:Filtek bulk - fill (3M ESPE) [FBF]、sufill SDR flow (Dentsply) [SDR]、fill - fill (COLTENE) [FU]和sufill (Dentsply) [SF]。在直径为6mm、厚度为4mm的模具中制备半圆柱形试样(n=5)。使用1000mw /cm2的光固化装置(Coltolux LED - Coltene)固化20秒。用三个压痕(Vickers Future Tech FM300, 300 g, 8 s)在四个深度:从上表面到内部1,2,3和4mm处测定HV。即刻(t0)和24小时后(t24)分别记录数据。结果采用双因素方差分析(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of microhardness of bulk-fill resins at different depths.

The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey's test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88);[SDR]t0:27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey's test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Update on the treatment of chemotherapy and radiotherapy-induced buccal mucositis: a systematic review. Clinical and microbiological assessment in a subpopulation of young Argentine patients with severe periodontitis. Postoperative pain after third molar extraction surgery in patients with and without bruxism: an observational study. Effect of photopolymerization time on the microhardness of resin cement beneath feldspathic ceramic. The potential of salivary albumin to degrade composite resin.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1