{"title":"[CT灌注联合能谱成像评价支气管动脉化疗栓塞治疗肺癌的近期疗效]。","authors":"L Q Lai, G H Lin, W Y Chen, J F Tu, J S Ji","doi":"10.3760/cma.j.cn112138-20220513-00366","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To evaluate the clinical value of dynamic volumetric CT perfusion combined with energy spectrum imaging in bronchial arterial chemoembolization (BACE) in patients with lung cancer. <b>Methods:</b> The data of 31 patients with lung cancer confirmed by pathology and treated with BACE in Lishui Central Hospital from January 2018 to February 2022 were retrospectively collected, including 23 men and 8 women, aged 31-84 (67) years. All patients received perfusion scans of lesion sites within 1 week before surgery and 1 month after surgery. We collected and compared the changes in preoperative and postoperative perfusion parameters such as blood flow (BF), blood volume (BV), mean through time (MTT), permeability surface (PS) and energy spectrum parameters including arterial phase CT value (CTA), venous phase CT value (CTV), arterial phase iodine concentration (ICA), venous phase of iodine concentration (ICV), arterial standardization iodine concentration (NICA), and intravenous standardized iodine concentration (NICV) to confirm the significance of these parameters in evaluating the short-term efficacy of BACE in the treatment of advanced lung cancer. Data normality was tested using the Kolmogorov-Smirnov test and normally distributed measurement data are expressed here as mean ± standard deviation; the independent-samples <i>t</i>-test was used for comparisons between two groups. The measurement data that were not normally distributed are expressed as median (interquartile interval) [<i>M</i> (<i>Q</i><sub>1</sub>, <i>Q</i><sub>3</sub>)], and the comparison between the two groups used the Kruskal-Wallis test. Count data are expressed as cases (%), and comparisons between groups used the <i>χ</i><sup>2</sup> test. <b>Results:</b> The objective response rate (ORR) and disease control rate (DCR) at 1 month after BACE were 54.8% (17/31) and 96.8% (30/31), respectively. CT perfusion parameters and energy spectrum parameters of patients before and after BACE treatment were compared. The results showed that BF, BV, MTT, ICA, ICV and NICV were significantly decreased after BACE treatment compared with before treatment, and the differences were statistically significant[58.06 (40.47,87.22) vs.23.57(10.92, 36.24) ml·min<sup>-1</sup>·100g<sup>-1</sup>,3.33(2.86,6.09) vs.2.12(1.96,3.61)ml/100g,2.70(2.19,3.88) vs.1.53 (1.12,2.25)s, 3.51 (3.11,4.14)vs.1.74 (1.26,2.50)mg/ml,2.00 (1.30,2.45) vs.1.32(0.92,1.76)mg/ml,0.51(0.42,0.57) vs.0.33(0.23,0.39)](all <i>P<</i>0.05). At the same time, compared with the non-remission group, the study results showed that the difference of parameters in remission group before and after BACE was more obvious, including ΔBF, ΔBV, ΔMTT, ΔPS, ΔCTA, ΔCTV, ΔICA, ΔICV, ΔNICA, ΔNICV were significantly increased, and the difference was statistically significant [36.82(32.38, 45.34) vs.9.50(-1.43, 12.34) ml·min<sup>-1</sup>·100g<sup>-1</sup>,4.46(2.52, 5.79) vs.0.22(-0.76, 4.09) ml/100g,4.22(2.25, 6.77) vs.0.43(-2.53, 1.88) s,10.07 (2.89, 13.13) vs.-2.01(-6.77, 4.28) ml·min<sup>-1</sup>·100g<sup>-1</sup>,14.22(11.88, 20.57) vs.4.18(-5.25, 6.37) HU, 34.6(14.88, 43.15) vs.11.60(0.26, 25.05) HU,0.95(0.54, 1.47) vs.0.11(0.20, 0.59) mg/ml,1.57(1.10, 2.38) vs. 0.26(-0.21, 0.63) mg/ml,0.05(0.03, 0.08) vs.-0.02(-0.04, 0.01),0.18(0.13, 0.21)vs. 0.11(-0.06, 0.16)](all <i>P<</i>0.05). <b>Conclusions:</b> CT perfusion combined with spectral imaging could effectively evaluate the changes in tumor vascular perfusion in patients with advanced lung cancer before and after BACE treatment, which has important value in judging the short-term efficacy after treatment.</p>","PeriodicalId":24000,"journal":{"name":"Zhonghua nei ke za zhi","volume":"62 5","pages":"539-544"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[CT perfusion combined with energy spectrum imaging to evaluate the short-term efficacy of bronchial arterial chemoembolization for lung cancer].\",\"authors\":\"L Q Lai, G H Lin, W Y Chen, J F Tu, J S Ji\",\"doi\":\"10.3760/cma.j.cn112138-20220513-00366\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To evaluate the clinical value of dynamic volumetric CT perfusion combined with energy spectrum imaging in bronchial arterial chemoembolization (BACE) in patients with lung cancer. <b>Methods:</b> The data of 31 patients with lung cancer confirmed by pathology and treated with BACE in Lishui Central Hospital from January 2018 to February 2022 were retrospectively collected, including 23 men and 8 women, aged 31-84 (67) years. All patients received perfusion scans of lesion sites within 1 week before surgery and 1 month after surgery. We collected and compared the changes in preoperative and postoperative perfusion parameters such as blood flow (BF), blood volume (BV), mean through time (MTT), permeability surface (PS) and energy spectrum parameters including arterial phase CT value (CTA), venous phase CT value (CTV), arterial phase iodine concentration (ICA), venous phase of iodine concentration (ICV), arterial standardization iodine concentration (NICA), and intravenous standardized iodine concentration (NICV) to confirm the significance of these parameters in evaluating the short-term efficacy of BACE in the treatment of advanced lung cancer. Data normality was tested using the Kolmogorov-Smirnov test and normally distributed measurement data are expressed here as mean ± standard deviation; the independent-samples <i>t</i>-test was used for comparisons between two groups. The measurement data that were not normally distributed are expressed as median (interquartile interval) [<i>M</i> (<i>Q</i><sub>1</sub>, <i>Q</i><sub>3</sub>)], and the comparison between the two groups used the Kruskal-Wallis test. Count data are expressed as cases (%), and comparisons between groups used the <i>χ</i><sup>2</sup> test. <b>Results:</b> The objective response rate (ORR) and disease control rate (DCR) at 1 month after BACE were 54.8% (17/31) and 96.8% (30/31), respectively. CT perfusion parameters and energy spectrum parameters of patients before and after BACE treatment were compared. The results showed that BF, BV, MTT, ICA, ICV and NICV were significantly decreased after BACE treatment compared with before treatment, and the differences were statistically significant[58.06 (40.47,87.22) vs.23.57(10.92, 36.24) ml·min<sup>-1</sup>·100g<sup>-1</sup>,3.33(2.86,6.09) vs.2.12(1.96,3.61)ml/100g,2.70(2.19,3.88) vs.1.53 (1.12,2.25)s, 3.51 (3.11,4.14)vs.1.74 (1.26,2.50)mg/ml,2.00 (1.30,2.45) vs.1.32(0.92,1.76)mg/ml,0.51(0.42,0.57) vs.0.33(0.23,0.39)](all <i>P<</i>0.05). At the same time, compared with the non-remission group, the study results showed that the difference of parameters in remission group before and after BACE was more obvious, including ΔBF, ΔBV, ΔMTT, ΔPS, ΔCTA, ΔCTV, ΔICA, ΔICV, ΔNICA, ΔNICV were significantly increased, and the difference was statistically significant [36.82(32.38, 45.34) vs.9.50(-1.43, 12.34) ml·min<sup>-1</sup>·100g<sup>-1</sup>,4.46(2.52, 5.79) vs.0.22(-0.76, 4.09) ml/100g,4.22(2.25, 6.77) vs.0.43(-2.53, 1.88) s,10.07 (2.89, 13.13) vs.-2.01(-6.77, 4.28) ml·min<sup>-1</sup>·100g<sup>-1</sup>,14.22(11.88, 20.57) vs.4.18(-5.25, 6.37) HU, 34.6(14.88, 43.15) vs.11.60(0.26, 25.05) HU,0.95(0.54, 1.47) vs.0.11(0.20, 0.59) mg/ml,1.57(1.10, 2.38) vs. 0.26(-0.21, 0.63) mg/ml,0.05(0.03, 0.08) vs.-0.02(-0.04, 0.01),0.18(0.13, 0.21)vs. 0.11(-0.06, 0.16)](all <i>P<</i>0.05). <b>Conclusions:</b> CT perfusion combined with spectral imaging could effectively evaluate the changes in tumor vascular perfusion in patients with advanced lung cancer before and after BACE treatment, which has important value in judging the short-term efficacy after treatment.</p>\",\"PeriodicalId\":24000,\"journal\":{\"name\":\"Zhonghua nei ke za zhi\",\"volume\":\"62 5\",\"pages\":\"539-544\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhonghua nei ke za zhi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112138-20220513-00366\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua nei ke za zhi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112138-20220513-00366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[CT perfusion combined with energy spectrum imaging to evaluate the short-term efficacy of bronchial arterial chemoembolization for lung cancer].
Objective: To evaluate the clinical value of dynamic volumetric CT perfusion combined with energy spectrum imaging in bronchial arterial chemoembolization (BACE) in patients with lung cancer. Methods: The data of 31 patients with lung cancer confirmed by pathology and treated with BACE in Lishui Central Hospital from January 2018 to February 2022 were retrospectively collected, including 23 men and 8 women, aged 31-84 (67) years. All patients received perfusion scans of lesion sites within 1 week before surgery and 1 month after surgery. We collected and compared the changes in preoperative and postoperative perfusion parameters such as blood flow (BF), blood volume (BV), mean through time (MTT), permeability surface (PS) and energy spectrum parameters including arterial phase CT value (CTA), venous phase CT value (CTV), arterial phase iodine concentration (ICA), venous phase of iodine concentration (ICV), arterial standardization iodine concentration (NICA), and intravenous standardized iodine concentration (NICV) to confirm the significance of these parameters in evaluating the short-term efficacy of BACE in the treatment of advanced lung cancer. Data normality was tested using the Kolmogorov-Smirnov test and normally distributed measurement data are expressed here as mean ± standard deviation; the independent-samples t-test was used for comparisons between two groups. The measurement data that were not normally distributed are expressed as median (interquartile interval) [M (Q1, Q3)], and the comparison between the two groups used the Kruskal-Wallis test. Count data are expressed as cases (%), and comparisons between groups used the χ2 test. Results: The objective response rate (ORR) and disease control rate (DCR) at 1 month after BACE were 54.8% (17/31) and 96.8% (30/31), respectively. CT perfusion parameters and energy spectrum parameters of patients before and after BACE treatment were compared. The results showed that BF, BV, MTT, ICA, ICV and NICV were significantly decreased after BACE treatment compared with before treatment, and the differences were statistically significant[58.06 (40.47,87.22) vs.23.57(10.92, 36.24) ml·min-1·100g-1,3.33(2.86,6.09) vs.2.12(1.96,3.61)ml/100g,2.70(2.19,3.88) vs.1.53 (1.12,2.25)s, 3.51 (3.11,4.14)vs.1.74 (1.26,2.50)mg/ml,2.00 (1.30,2.45) vs.1.32(0.92,1.76)mg/ml,0.51(0.42,0.57) vs.0.33(0.23,0.39)](all P<0.05). At the same time, compared with the non-remission group, the study results showed that the difference of parameters in remission group before and after BACE was more obvious, including ΔBF, ΔBV, ΔMTT, ΔPS, ΔCTA, ΔCTV, ΔICA, ΔICV, ΔNICA, ΔNICV were significantly increased, and the difference was statistically significant [36.82(32.38, 45.34) vs.9.50(-1.43, 12.34) ml·min-1·100g-1,4.46(2.52, 5.79) vs.0.22(-0.76, 4.09) ml/100g,4.22(2.25, 6.77) vs.0.43(-2.53, 1.88) s,10.07 (2.89, 13.13) vs.-2.01(-6.77, 4.28) ml·min-1·100g-1,14.22(11.88, 20.57) vs.4.18(-5.25, 6.37) HU, 34.6(14.88, 43.15) vs.11.60(0.26, 25.05) HU,0.95(0.54, 1.47) vs.0.11(0.20, 0.59) mg/ml,1.57(1.10, 2.38) vs. 0.26(-0.21, 0.63) mg/ml,0.05(0.03, 0.08) vs.-0.02(-0.04, 0.01),0.18(0.13, 0.21)vs. 0.11(-0.06, 0.16)](all P<0.05). Conclusions: CT perfusion combined with spectral imaging could effectively evaluate the changes in tumor vascular perfusion in patients with advanced lung cancer before and after BACE treatment, which has important value in judging the short-term efficacy after treatment.