{"title":"酒精消费对商业眨眼睡意检测技术的影响","authors":"Jennifer M. Cori, Vanessa E. Wilkinson, Melinda Jackson, Justine Westlake, Bronwyn Stevens, Maree Barnes, Philip Swann, Mark E. Howard","doi":"10.1002/hup.2870","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Driver drowsiness detection technology that assesses eye blinks is increasingly being used as a safety intervention in the transport industry. It is unclear how alcohol consumption to common legal driving limits impacts upon this technology. The aim of the study was to assess the impact of a blood alcohol content (BAC) of 0.05% and of 0.08% on drowsiness detection technology during simulated driving.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Participants completed a 60-min driving simulation and sleepiness questionnaire under three conditions: 1–0.00% BAC, 2–0.05% BAC and 3–0.08% BAC. During the driving simulation task participants wore a commercial eye blink drowsiness detection technology (Optalert) with the drowsiness alarms silenced.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Twelve participants (3 female) completed all alcohol conditions. Relative to baseline, all eye blink parameters were affected at 0.08% BAC (all <i>p</i> < 0.05), whereas 0.05% BAC only affected the composite eye blink drowsiness measure (the Johns Drowsiness Scale).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Alcohol consumption to 0.08% BAC impaired eye blink measures to a level that would be considered a moderate drowsiness risk. Therefore, employers should be aware that drowsiness alerts from these technologies may increase after alcohol consumption.</p>\n </section>\n </div>","PeriodicalId":13030,"journal":{"name":"Human Psychopharmacology: Clinical and Experimental","volume":"38 4","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/hup.2870","citationCount":"0","resultStr":"{\"title\":\"The impact of alcohol consumption on commercial eye blink drowsiness detection technology\",\"authors\":\"Jennifer M. Cori, Vanessa E. Wilkinson, Melinda Jackson, Justine Westlake, Bronwyn Stevens, Maree Barnes, Philip Swann, Mark E. Howard\",\"doi\":\"10.1002/hup.2870\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Driver drowsiness detection technology that assesses eye blinks is increasingly being used as a safety intervention in the transport industry. It is unclear how alcohol consumption to common legal driving limits impacts upon this technology. The aim of the study was to assess the impact of a blood alcohol content (BAC) of 0.05% and of 0.08% on drowsiness detection technology during simulated driving.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Participants completed a 60-min driving simulation and sleepiness questionnaire under three conditions: 1–0.00% BAC, 2–0.05% BAC and 3–0.08% BAC. During the driving simulation task participants wore a commercial eye blink drowsiness detection technology (Optalert) with the drowsiness alarms silenced.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Twelve participants (3 female) completed all alcohol conditions. Relative to baseline, all eye blink parameters were affected at 0.08% BAC (all <i>p</i> < 0.05), whereas 0.05% BAC only affected the composite eye blink drowsiness measure (the Johns Drowsiness Scale).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Alcohol consumption to 0.08% BAC impaired eye blink measures to a level that would be considered a moderate drowsiness risk. Therefore, employers should be aware that drowsiness alerts from these technologies may increase after alcohol consumption.</p>\\n </section>\\n </div>\",\"PeriodicalId\":13030,\"journal\":{\"name\":\"Human Psychopharmacology: Clinical and Experimental\",\"volume\":\"38 4\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/hup.2870\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Human Psychopharmacology: Clinical and Experimental\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/hup.2870\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Psychopharmacology: Clinical and Experimental","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/hup.2870","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
The impact of alcohol consumption on commercial eye blink drowsiness detection technology
Introduction
Driver drowsiness detection technology that assesses eye blinks is increasingly being used as a safety intervention in the transport industry. It is unclear how alcohol consumption to common legal driving limits impacts upon this technology. The aim of the study was to assess the impact of a blood alcohol content (BAC) of 0.05% and of 0.08% on drowsiness detection technology during simulated driving.
Methods
Participants completed a 60-min driving simulation and sleepiness questionnaire under three conditions: 1–0.00% BAC, 2–0.05% BAC and 3–0.08% BAC. During the driving simulation task participants wore a commercial eye blink drowsiness detection technology (Optalert) with the drowsiness alarms silenced.
Results
Twelve participants (3 female) completed all alcohol conditions. Relative to baseline, all eye blink parameters were affected at 0.08% BAC (all p < 0.05), whereas 0.05% BAC only affected the composite eye blink drowsiness measure (the Johns Drowsiness Scale).
Conclusions
Alcohol consumption to 0.08% BAC impaired eye blink measures to a level that would be considered a moderate drowsiness risk. Therefore, employers should be aware that drowsiness alerts from these technologies may increase after alcohol consumption.
期刊介绍:
Human Psychopharmacology: Clinical and Experimental provides a forum for the evaluation of clinical and experimental research on both new and established psychotropic medicines. Experimental studies of other centrally active drugs, including herbal products, in clinical, social and psychological contexts, as well as clinical/scientific papers on drugs of abuse and drug dependency will also be considered. While the primary purpose of the Journal is to publish the results of clinical research, the results of animal studies relevant to human psychopharmacology are welcome. The following topics are of special interest to the editors and readers of the Journal:
-All aspects of clinical psychopharmacology-
Efficacy and safety studies of novel and standard psychotropic drugs-
Studies of the adverse effects of psychotropic drugs-
Effects of psychotropic drugs on normal physiological processes-
Geriatric and paediatric psychopharmacology-
Ethical and psychosocial aspects of drug use and misuse-
Psychopharmacological aspects of sleep and chronobiology-
Neuroimaging and psychoactive drugs-
Phytopharmacology and psychoactive substances-
Drug treatment of neurological disorders-
Mechanisms of action of psychotropic drugs-
Ethnopsychopharmacology-
Pharmacogenetic aspects of mental illness and drug response-
Psychometrics: psychopharmacological methods and experimental design