使用新型3D重建测量技术确定患者特异性气道支架贴合:对患者进行4年随访。

IF 3.3 3区 医学 Q2 RESPIRATORY SYSTEM Therapeutic Advances in Respiratory Disease Pub Date : 2023-01-01 DOI:10.1177/17534666221137999
Prince Ntiamoah, Thomas R Gildea, Adrianna Baiera
{"title":"使用新型3D重建测量技术确定患者特异性气道支架贴合:对患者进行4年随访。","authors":"Prince Ntiamoah,&nbsp;Thomas R Gildea,&nbsp;Adrianna Baiera","doi":"10.1177/17534666221137999","DOIUrl":null,"url":null,"abstract":"<p><p>Managing complex benign airway disease is a major challenge in interventional pulmonology. With the introduction of additive manufacturing in the medical field, patient-specific (PS) implants are an innovate prospect for airway management. Historically, stents were oversized to resist migration. However, the optimal degree and impact of stent oversizing remains unclear. The ability to design stents based on computed tomography (CT) invites opportunity to understand sizing. Here, we report a novel three-dimensional (3D) image reconstruction tool to quantify fit repeatedly over time. Analysis of CT imaging before and after successive stent implants in a single patient with different areas of stenosis and malacia was done. Nine PS airway stents over 4 years (five left mainstem and four right mainstem) were studied. The distance between the airway model and stent was calculated. The CT images were correlated to stent designs in CloudCompare software (v2.10-alpha) for novel analysis. Heat map was exported depicting the distances between the airway and the stent to the clinician's prescribed stent model. Corresponding histograms containing distances, mean, and standard deviation were reported. It is possible to measure stent fit based on heat map quantification on patient imaging. Observation of the airway over time and stent change suggests that the airway became more open over time requiring increased stent diameters. The ability to design and measure stent fit over time can help quantify the utility and impact of PS silicone airway stent. The airway appears to display plasticity such that there is notable change in stent prescription over time.</p>","PeriodicalId":22884,"journal":{"name":"Therapeutic Advances in Respiratory Disease","volume":"17 ","pages":"17534666221137999"},"PeriodicalIF":3.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/33/9c/10.1177_17534666221137999.PMC10185860.pdf","citationCount":"3","resultStr":"{\"title\":\"Determination of patient-specific airway stent fit using novel 3D reconstruction measurement techniques: a 4-year follow-up of a patient.\",\"authors\":\"Prince Ntiamoah,&nbsp;Thomas R Gildea,&nbsp;Adrianna Baiera\",\"doi\":\"10.1177/17534666221137999\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Managing complex benign airway disease is a major challenge in interventional pulmonology. With the introduction of additive manufacturing in the medical field, patient-specific (PS) implants are an innovate prospect for airway management. Historically, stents were oversized to resist migration. However, the optimal degree and impact of stent oversizing remains unclear. The ability to design stents based on computed tomography (CT) invites opportunity to understand sizing. Here, we report a novel three-dimensional (3D) image reconstruction tool to quantify fit repeatedly over time. Analysis of CT imaging before and after successive stent implants in a single patient with different areas of stenosis and malacia was done. Nine PS airway stents over 4 years (five left mainstem and four right mainstem) were studied. The distance between the airway model and stent was calculated. The CT images were correlated to stent designs in CloudCompare software (v2.10-alpha) for novel analysis. Heat map was exported depicting the distances between the airway and the stent to the clinician's prescribed stent model. Corresponding histograms containing distances, mean, and standard deviation were reported. It is possible to measure stent fit based on heat map quantification on patient imaging. Observation of the airway over time and stent change suggests that the airway became more open over time requiring increased stent diameters. The ability to design and measure stent fit over time can help quantify the utility and impact of PS silicone airway stent. The airway appears to display plasticity such that there is notable change in stent prescription over time.</p>\",\"PeriodicalId\":22884,\"journal\":{\"name\":\"Therapeutic Advances in Respiratory Disease\",\"volume\":\"17 \",\"pages\":\"17534666221137999\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/33/9c/10.1177_17534666221137999.PMC10185860.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Therapeutic Advances in Respiratory Disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17534666221137999\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Respiratory Disease","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17534666221137999","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 3

摘要

处理复杂的良性气道疾病是介入肺脏学的主要挑战。随着增材制造在医疗领域的引入,患者特异性(PS)植入物是气道管理的创新前景。从历史上看,支架是超大的,以防止迁移。然而,支架过大的最佳程度和影响尚不清楚。基于计算机断层扫描(CT)设计支架的能力为了解支架尺寸提供了机会。在这里,我们报告了一种新的三维(3D)图像重建工具,可以随着时间的推移反复量化拟合。分析1例不同区域狭窄伴软化患者连续植入支架前后的CT图像。对9例PS气道支架进行了为期4年的研究,其中5例为左主干,4例为右主干。计算气道模型与支架之间的距离。在CloudCompare软件(v2.10-alpha)中将CT图像与支架设计相关联,进行新的分析。导出热图,将气道与支架之间的距离描绘为临床医生规定的支架模型。报告了相应的直方图,其中包含距离、平均值和标准差。可以根据患者成像的热图量化来测量支架的配合度。对气道随时间变化和支架变化的观察表明,随着时间的推移,气道变得更加开放,需要增加支架直径。随着时间的推移,设计和测量支架配合的能力可以帮助量化PS硅胶气道支架的效用和影响。随着时间的推移,气道似乎显示出可塑性,因此支架处方有显著的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of patient-specific airway stent fit using novel 3D reconstruction measurement techniques: a 4-year follow-up of a patient.

Managing complex benign airway disease is a major challenge in interventional pulmonology. With the introduction of additive manufacturing in the medical field, patient-specific (PS) implants are an innovate prospect for airway management. Historically, stents were oversized to resist migration. However, the optimal degree and impact of stent oversizing remains unclear. The ability to design stents based on computed tomography (CT) invites opportunity to understand sizing. Here, we report a novel three-dimensional (3D) image reconstruction tool to quantify fit repeatedly over time. Analysis of CT imaging before and after successive stent implants in a single patient with different areas of stenosis and malacia was done. Nine PS airway stents over 4 years (five left mainstem and four right mainstem) were studied. The distance between the airway model and stent was calculated. The CT images were correlated to stent designs in CloudCompare software (v2.10-alpha) for novel analysis. Heat map was exported depicting the distances between the airway and the stent to the clinician's prescribed stent model. Corresponding histograms containing distances, mean, and standard deviation were reported. It is possible to measure stent fit based on heat map quantification on patient imaging. Observation of the airway over time and stent change suggests that the airway became more open over time requiring increased stent diameters. The ability to design and measure stent fit over time can help quantify the utility and impact of PS silicone airway stent. The airway appears to display plasticity such that there is notable change in stent prescription over time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.90
自引率
0.00%
发文量
57
审稿时长
15 weeks
期刊介绍: Therapeutic Advances in Respiratory Disease delivers the highest quality peer-reviewed articles, reviews, and scholarly comment on pioneering efforts and innovative studies across all areas of respiratory disease.
期刊最新文献
Prone positioning during CPAP therapy in SARS-CoV-2 pneumonia: a concise clinical review. Liver injury due to endothelin receptor antagonists: a real-world study based on post-marketing drug monitoring data. Referral rates and barriers to lung transplantation based on pulmonary function criteria in interstitial lung diseases: a retrospective cohort study. A comparison between a gastroesophageal reflux disease questionnaire-based algorithm and multichannel intraluminal impedance-pH monitoring for the treatment of gastroesophageal reflux-induced chronic cough. Post-reflux swallow-induced peristaltic wave index: a new parameter for the identification of non-acid gastroesophageal reflux-related chronic cough.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1