创新、自动化和信息学提高泰国Lerdsin医院的质量。

IF 2.7 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY British Journal of Biomedical Science Pub Date : 2023-01-01 DOI:10.3389/bjbs.2023.11532
Adchada Karnchanaphiboonwong, Patcharawadee Sringam, Kawinna Niwattakul, Teerayut Krommuang, Alistair Gammie
{"title":"创新、自动化和信息学提高泰国Lerdsin医院的质量。","authors":"Adchada Karnchanaphiboonwong,&nbsp;Patcharawadee Sringam,&nbsp;Kawinna Niwattakul,&nbsp;Teerayut Krommuang,&nbsp;Alistair Gammie","doi":"10.3389/bjbs.2023.11532","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes a planned, continuous improvement journey, of a laboratory that has installed a system with a single sample touch from blood draw to result. To achieve this, physical connectivity of systems from phlebotomy through pre-analytical to the analytical phase were paired with informatics connectivity from the patient's national identity card to the hospital and laboratory informatics management systems (LIMS) and associated middleware. This allowed accurate time stamps to track turnaround time (TAT). TAT metrics were collected from the LIMS for inpatient, emergency room and outpatient samples and tests over a period of 7 months. This time span incorporated the 2-month period before automation was implemented. The results for all tests and specific tests are shown and the results of an analysis of the outpatient phlebotomy workflow are given. The implemented solution has improved outpatient TAT by over 54% and has shown that samples can be collected, and results obtained without touching the sample. Improving intra-laboratory TAT is an important quality goal for all laboratories. The implementation of automation is important in achieving this albeit more about obtaining predictable TAT. Automation does not necessarily improve TAT it removes variation which leads to predictable TAT (PTAT). Automation should only be considered with a strategic vision for the future as it is important to have clear goals and objectives based on the individual laboratories process and needs. Automating a poor process leads to an automated poor process. Here, an innovative use of automation, hardware and software has resulted in marked improvement in TAT across all samples processed in the central laboratory.</p>","PeriodicalId":9236,"journal":{"name":"British Journal of Biomedical Science","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317056/pdf/","citationCount":"0","resultStr":"{\"title\":\"Innovation, Automation and Informatics Improves Quality in Lerdsin Hospital, Thailand.\",\"authors\":\"Adchada Karnchanaphiboonwong,&nbsp;Patcharawadee Sringam,&nbsp;Kawinna Niwattakul,&nbsp;Teerayut Krommuang,&nbsp;Alistair Gammie\",\"doi\":\"10.3389/bjbs.2023.11532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper describes a planned, continuous improvement journey, of a laboratory that has installed a system with a single sample touch from blood draw to result. To achieve this, physical connectivity of systems from phlebotomy through pre-analytical to the analytical phase were paired with informatics connectivity from the patient's national identity card to the hospital and laboratory informatics management systems (LIMS) and associated middleware. This allowed accurate time stamps to track turnaround time (TAT). TAT metrics were collected from the LIMS for inpatient, emergency room and outpatient samples and tests over a period of 7 months. This time span incorporated the 2-month period before automation was implemented. The results for all tests and specific tests are shown and the results of an analysis of the outpatient phlebotomy workflow are given. The implemented solution has improved outpatient TAT by over 54% and has shown that samples can be collected, and results obtained without touching the sample. Improving intra-laboratory TAT is an important quality goal for all laboratories. The implementation of automation is important in achieving this albeit more about obtaining predictable TAT. Automation does not necessarily improve TAT it removes variation which leads to predictable TAT (PTAT). Automation should only be considered with a strategic vision for the future as it is important to have clear goals and objectives based on the individual laboratories process and needs. Automating a poor process leads to an automated poor process. Here, an innovative use of automation, hardware and software has resulted in marked improvement in TAT across all samples processed in the central laboratory.</p>\",\"PeriodicalId\":9236,\"journal\":{\"name\":\"British Journal of Biomedical Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10317056/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British Journal of Biomedical Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3389/bjbs.2023.11532\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Biomedical Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/bjbs.2023.11532","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了一个实验室的计划,持续改进之旅,该实验室安装了一个系统,从抽血到结果只有一次样本接触。为了实现这一目标,从静脉穿刺到预分析再到分析阶段的系统的物理连接与从患者的国民身份证到医院和实验室信息管理系统(LIMS)和相关中间件的信息连接相匹配。这允许精确的时间戳来跟踪周转时间(TAT)。在7个月的时间里,从LIMS收集住院病人、急诊室和门诊病人的样本和测试的TAT指标。这个时间跨度包括自动化实现之前的2个月。所有测试和特定测试的结果显示,结果分析门诊静脉切开术工作流程给出。实施的解决方案使门诊TAT提高了54%以上,并且表明可以收集样本,并且无需接触样本即可获得结果。提高实验室内TAT是所有实验室的重要质量目标。自动化的实施对于实现这一目标很重要,尽管更多的是为了获得可预测的TAT。自动化并不一定改善TAT,它消除了导致可预测TAT (PTAT)的变化。自动化应该只考虑未来的战略愿景,因为根据个别实验室的过程和需求有明确的目标和目的是很重要的。自动化一个糟糕的过程会导致一个自动化的糟糕的过程。在这里,自动化、硬件和软件的创新使用导致了在中心实验室处理的所有样品的TAT的显著改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Innovation, Automation and Informatics Improves Quality in Lerdsin Hospital, Thailand.

This paper describes a planned, continuous improvement journey, of a laboratory that has installed a system with a single sample touch from blood draw to result. To achieve this, physical connectivity of systems from phlebotomy through pre-analytical to the analytical phase were paired with informatics connectivity from the patient's national identity card to the hospital and laboratory informatics management systems (LIMS) and associated middleware. This allowed accurate time stamps to track turnaround time (TAT). TAT metrics were collected from the LIMS for inpatient, emergency room and outpatient samples and tests over a period of 7 months. This time span incorporated the 2-month period before automation was implemented. The results for all tests and specific tests are shown and the results of an analysis of the outpatient phlebotomy workflow are given. The implemented solution has improved outpatient TAT by over 54% and has shown that samples can be collected, and results obtained without touching the sample. Improving intra-laboratory TAT is an important quality goal for all laboratories. The implementation of automation is important in achieving this albeit more about obtaining predictable TAT. Automation does not necessarily improve TAT it removes variation which leads to predictable TAT (PTAT). Automation should only be considered with a strategic vision for the future as it is important to have clear goals and objectives based on the individual laboratories process and needs. Automating a poor process leads to an automated poor process. Here, an innovative use of automation, hardware and software has resulted in marked improvement in TAT across all samples processed in the central laboratory.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
British Journal of Biomedical Science
British Journal of Biomedical Science 医学-医学实验技术
CiteScore
4.40
自引率
15.80%
发文量
29
审稿时长
>12 weeks
期刊介绍: The British Journal of Biomedical Science is committed to publishing high quality original research that represents a clear advance in the practice of biomedical science, and reviews that summarise recent advances in the field of biomedical science. The overall aim of the Journal is to provide a platform for the dissemination of new and innovative information on the diagnosis and management of disease that is valuable to the practicing laboratory scientist.
期刊最新文献
Improving Biomedical Science Literacy and Patient-Directed Knowledge of Tuberculosis (TB): A Cross-Sectional Infodemiology Study Examining Readability of Patient-Facing TB Information. Mesoporous Silica Microparticle-Protein Complexes: Effects of Protein Size and Solvent Properties on Diffusion and Loading Efficiency. Neuronal Vulnerability of the Entorhinal Cortex to Tau Pathology in Alzheimer's Disease. Evaluating Lung Changes in Long COVID: Ultra-Low-Dose vs. Standard-Dose CT Chest. Editorial: Advances in Cancer Diagnosis and Treatment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1