计算机辅助测量超声肾皮质回声的客观方法:脾肾指数

IF 0.7 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasound Quarterly Pub Date : 2024-03-01 DOI:10.1097/RUQ.0000000000000646
Bryce D Beutler, Bassim El-Sabawi, Daphne K Walker, Steven Cen, Hisham Tchelepi
{"title":"计算机辅助测量超声肾皮质回声的客观方法:脾肾指数","authors":"Bryce D Beutler, Bassim El-Sabawi, Daphne K Walker, Steven Cen, Hisham Tchelepi","doi":"10.1097/RUQ.0000000000000646","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Renal cortical echogenicity represents a marker of renal function. However, evaluation of the renal echotexture is subjective and thus disposed to error and interrater variability. Computer-aided image analysis may be used to objectively assess renal cortical echogenicity by comparing the echogenicity of the left kidney to that of the spleen; the resultant ratio is referred to as the splenorenal index (SRI). We performed a retrospective review of all adult patients who received a renal ultrasound over a 45-day period at our institution. Demographic data and kidney function laboratory values were documented for each patient. Regions of interest (ROIs) were selected in the left renal cortex and spleen using ImageJ software. The SRI was calculated as a ratio of the mean pixel brightness of the left kidney cortex ROI to the mean pixel brightness of the spleen ROI. The SRI was then correlated with serum creatinine, blood urea nitrogen, and estimated glomerular filtration rate. We found that among the 94 patients included in the study, the SRI had a significant positive correlation with serum creatinine ( r = 0.43, P < 0.001) and serum blood urea nitrogen ( r = 0.45, P < 0.001) and negative correlation with estimated glomerular filtration rate ( r = -0.47, P < 0.001). Our data indicate that SRI may serve as a valuable tool for sonographic evaluation of renal parenchymal disease.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Objective Computer-Assisted Measurement of Sonographic Renal Cortical Echogenicity: The Splenorenal Index.\",\"authors\":\"Bryce D Beutler, Bassim El-Sabawi, Daphne K Walker, Steven Cen, Hisham Tchelepi\",\"doi\":\"10.1097/RUQ.0000000000000646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>Renal cortical echogenicity represents a marker of renal function. However, evaluation of the renal echotexture is subjective and thus disposed to error and interrater variability. Computer-aided image analysis may be used to objectively assess renal cortical echogenicity by comparing the echogenicity of the left kidney to that of the spleen; the resultant ratio is referred to as the splenorenal index (SRI). We performed a retrospective review of all adult patients who received a renal ultrasound over a 45-day period at our institution. Demographic data and kidney function laboratory values were documented for each patient. Regions of interest (ROIs) were selected in the left renal cortex and spleen using ImageJ software. The SRI was calculated as a ratio of the mean pixel brightness of the left kidney cortex ROI to the mean pixel brightness of the spleen ROI. The SRI was then correlated with serum creatinine, blood urea nitrogen, and estimated glomerular filtration rate. We found that among the 94 patients included in the study, the SRI had a significant positive correlation with serum creatinine ( r = 0.43, P < 0.001) and serum blood urea nitrogen ( r = 0.45, P < 0.001) and negative correlation with estimated glomerular filtration rate ( r = -0.47, P < 0.001). Our data indicate that SRI may serve as a valuable tool for sonographic evaluation of renal parenchymal disease.</p>\",\"PeriodicalId\":49116,\"journal\":{\"name\":\"Ultrasound Quarterly\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Quarterly\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/RUQ.0000000000000646\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000646","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要:肾皮质回声是肾功能的标志。然而,对肾脏回声纹理的评估是主观的,因此容易产生误差和评定者之间的差异。计算机辅助图像分析可用于客观评估肾皮质回声,方法是比较左肾和脾脏的回声,得出的比率称为脾肾指数(SRI)。我们对本机构在 45 天内接受肾脏超声检查的所有成年患者进行了回顾性审查。记录了每位患者的人口统计学数据和肾功能实验室值。使用 ImageJ 软件在左肾皮质和脾脏中选择感兴趣区(ROI)。以左肾皮质 ROI 平均像素亮度与脾脏 ROI 平均像素亮度之比计算 SRI。然后将 SRI 与血清肌酐、血尿素氮和估计肾小球滤过率相关联。我们发现,在纳入研究的 94 名患者中,SRI 与血清肌酐(r = 0.43,P < 0.001)和血清尿素氮(r = 0.45,P < 0.001)呈显著正相关,而与估计肾小球滤过率(r = -0.47,P < 0.001)呈负相关。我们的数据表明,SRI 可作为肾实质疾病超声评估的重要工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An Objective Computer-Assisted Measurement of Sonographic Renal Cortical Echogenicity: The Splenorenal Index.

Abstract: Renal cortical echogenicity represents a marker of renal function. However, evaluation of the renal echotexture is subjective and thus disposed to error and interrater variability. Computer-aided image analysis may be used to objectively assess renal cortical echogenicity by comparing the echogenicity of the left kidney to that of the spleen; the resultant ratio is referred to as the splenorenal index (SRI). We performed a retrospective review of all adult patients who received a renal ultrasound over a 45-day period at our institution. Demographic data and kidney function laboratory values were documented for each patient. Regions of interest (ROIs) were selected in the left renal cortex and spleen using ImageJ software. The SRI was calculated as a ratio of the mean pixel brightness of the left kidney cortex ROI to the mean pixel brightness of the spleen ROI. The SRI was then correlated with serum creatinine, blood urea nitrogen, and estimated glomerular filtration rate. We found that among the 94 patients included in the study, the SRI had a significant positive correlation with serum creatinine ( r = 0.43, P < 0.001) and serum blood urea nitrogen ( r = 0.45, P < 0.001) and negative correlation with estimated glomerular filtration rate ( r = -0.47, P < 0.001). Our data indicate that SRI may serve as a valuable tool for sonographic evaluation of renal parenchymal disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
期刊最新文献
Objective Analysis of Predictive Value of Ultrasound Quantitative Scoring System for Treatment Method Selection in Cesarean Scar Pregnancy. Role of Combining Grayscale Findings With Superb Microvascular Imaging and Shear Wave Elastography in Standardization and Management of NON-MASS Breast Lesions. Nonvisualized Ovaries on Ultrasound: Correlation With Surgical Pathology. Reliability of a 2D-Panoramic Ultrasound System for the Determination of Muscle Volume in Older Hospitalized Patients. Pediatric Cranial Ultrasound Revisited: A Comprehensive Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1