Giovanni A Chiariello, Emmanuel Villa, Piergiorgio Bruno, Annalisa Pasquini, Marialisa Nesta, Francesco Ferraro, Serena D'Avino, Valerio Sanesi, Claudia Vecchio, Antonio Messina, Margherita Dalla Tomba, Maria Calabrese, Abdallah Raweh, Luca Montini, Giovanni Troise, Massimo Massetti
{"title":"两种创新的主动脉生物假体在现实世界中进行评估。第一个结果来自一项双中心研究。","authors":"Giovanni A Chiariello, Emmanuel Villa, Piergiorgio Bruno, Annalisa Pasquini, Marialisa Nesta, Francesco Ferraro, Serena D'Avino, Valerio Sanesi, Claudia Vecchio, Antonio Messina, Margherita Dalla Tomba, Maria Calabrese, Abdallah Raweh, Luca Montini, Giovanni Troise, Massimo Massetti","doi":"10.23736/S0021-9509.23.12534-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The increasing use of biological substitutes for surgical aortic valve replacement (AVR), has led to the development of new bioprostheses with improved hemodynamics and expected durability.</p><p><strong>Methods: </strong>In this observational retrospective two-center cohort study, two innovative bioprostheses, INSPIRIS Resilia and AVALUS were analyzed. We analyzed early and 2.4-year follow-up results in terms of safety, clinical outcome and hemodynamic performance.</p><p><strong>Results: </strong>From November 2017 to February 2021, 148 patients underwent AVR with INSPIRIS Resilia (N.=74) or AVALUS (N.=74) bioprosthesis. The 30-day and mid-term mortality was comparable (1% vs. 3%, P=0.1 and 7% vs. 4%, P=0.4, respectively). Valve-related mortality was observed in one AVALUS patient. Three (4%) patients of the AVALUS group developed prosthetic endocarditis and two of them died after reoperation. No other cases of prosthetic endocarditis were observed. No cases of structural valve degeneration or significant paravalvular leak were detected at follow-up. Median follow-up peak pressure gradient was 21 vs. 23 mmHg (P=0.4) and the mean pressure gradient was 12 vs. 13 mmHg (P=0.9) for Inspiris and AVALUS, respectively. The effective orifice area (EOA) and indexed EOA were 1.5 cm<sup>2</sup> vs. 1.4 cm<sup>2</sup> (P=0.4) and 0.8 vs. 0.7 cm<sup>2</sup>/m<sup>2</sup> (P=0.5), respectively. Indexed left ventricular mass regression was -33 vs. -52 g/m<sup>2</sup> for the Inspiris and AVALUS groups, respectively, (R<sup>2</sup>-adjusted =0.14; P<0.01).</p><p><strong>Conclusions: </strong>INSPIRIS Resilia and AVALUS bioprostheses were reliable with comparable results in safety, clinical outcome and hemodynamic performance. After statistical adjustment, AVALUS was associated with better left ventricular mass reduction. Long-term follow-up would provide definitive comparative results.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two innovative aortic bioprostheses evaluated in the real-world setting. First results from a two-center study.\",\"authors\":\"Giovanni A Chiariello, Emmanuel Villa, Piergiorgio Bruno, Annalisa Pasquini, Marialisa Nesta, Francesco Ferraro, Serena D'Avino, Valerio Sanesi, Claudia Vecchio, Antonio Messina, Margherita Dalla Tomba, Maria Calabrese, Abdallah Raweh, Luca Montini, Giovanni Troise, Massimo Massetti\",\"doi\":\"10.23736/S0021-9509.23.12534-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The increasing use of biological substitutes for surgical aortic valve replacement (AVR), has led to the development of new bioprostheses with improved hemodynamics and expected durability.</p><p><strong>Methods: </strong>In this observational retrospective two-center cohort study, two innovative bioprostheses, INSPIRIS Resilia and AVALUS were analyzed. We analyzed early and 2.4-year follow-up results in terms of safety, clinical outcome and hemodynamic performance.</p><p><strong>Results: </strong>From November 2017 to February 2021, 148 patients underwent AVR with INSPIRIS Resilia (N.=74) or AVALUS (N.=74) bioprosthesis. The 30-day and mid-term mortality was comparable (1% vs. 3%, P=0.1 and 7% vs. 4%, P=0.4, respectively). Valve-related mortality was observed in one AVALUS patient. Three (4%) patients of the AVALUS group developed prosthetic endocarditis and two of them died after reoperation. No other cases of prosthetic endocarditis were observed. No cases of structural valve degeneration or significant paravalvular leak were detected at follow-up. Median follow-up peak pressure gradient was 21 vs. 23 mmHg (P=0.4) and the mean pressure gradient was 12 vs. 13 mmHg (P=0.9) for Inspiris and AVALUS, respectively. The effective orifice area (EOA) and indexed EOA were 1.5 cm<sup>2</sup> vs. 1.4 cm<sup>2</sup> (P=0.4) and 0.8 vs. 0.7 cm<sup>2</sup>/m<sup>2</sup> (P=0.5), respectively. Indexed left ventricular mass regression was -33 vs. -52 g/m<sup>2</sup> for the Inspiris and AVALUS groups, respectively, (R<sup>2</sup>-adjusted =0.14; P<0.01).</p><p><strong>Conclusions: </strong>INSPIRIS Resilia and AVALUS bioprostheses were reliable with comparable results in safety, clinical outcome and hemodynamic performance. After statistical adjustment, AVALUS was associated with better left ventricular mass reduction. Long-term follow-up would provide definitive comparative results.</p>\",\"PeriodicalId\":50245,\"journal\":{\"name\":\"Journal of Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S0021-9509.23.12534-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.23.12534-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Two innovative aortic bioprostheses evaluated in the real-world setting. First results from a two-center study.
Background: The increasing use of biological substitutes for surgical aortic valve replacement (AVR), has led to the development of new bioprostheses with improved hemodynamics and expected durability.
Methods: In this observational retrospective two-center cohort study, two innovative bioprostheses, INSPIRIS Resilia and AVALUS were analyzed. We analyzed early and 2.4-year follow-up results in terms of safety, clinical outcome and hemodynamic performance.
Results: From November 2017 to February 2021, 148 patients underwent AVR with INSPIRIS Resilia (N.=74) or AVALUS (N.=74) bioprosthesis. The 30-day and mid-term mortality was comparable (1% vs. 3%, P=0.1 and 7% vs. 4%, P=0.4, respectively). Valve-related mortality was observed in one AVALUS patient. Three (4%) patients of the AVALUS group developed prosthetic endocarditis and two of them died after reoperation. No other cases of prosthetic endocarditis were observed. No cases of structural valve degeneration or significant paravalvular leak were detected at follow-up. Median follow-up peak pressure gradient was 21 vs. 23 mmHg (P=0.4) and the mean pressure gradient was 12 vs. 13 mmHg (P=0.9) for Inspiris and AVALUS, respectively. The effective orifice area (EOA) and indexed EOA were 1.5 cm2 vs. 1.4 cm2 (P=0.4) and 0.8 vs. 0.7 cm2/m2 (P=0.5), respectively. Indexed left ventricular mass regression was -33 vs. -52 g/m2 for the Inspiris and AVALUS groups, respectively, (R2-adjusted =0.14; P<0.01).
Conclusions: INSPIRIS Resilia and AVALUS bioprostheses were reliable with comparable results in safety, clinical outcome and hemodynamic performance. After statistical adjustment, AVALUS was associated with better left ventricular mass reduction. Long-term follow-up would provide definitive comparative results.
期刊介绍:
The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.