机械取栓治疗急性肢体缺血:INDIAN UP试验的中期结果。

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Surgery Pub Date : 2023-06-01 DOI:10.23736/S0021-9509.23.12668-1
Gianmarco de Donato, Edoardo Pasqui, Maria A Ruffino, Massimo Sponza, Angelo Spinazzola, Giuseppe Guzzardi, Francesco Intrieri, Daniele Savio, Giancarlo Palasciano
{"title":"机械取栓治疗急性肢体缺血:INDIAN UP试验的中期结果。","authors":"Gianmarco de Donato,&nbsp;Edoardo Pasqui,&nbsp;Maria A Ruffino,&nbsp;Massimo Sponza,&nbsp;Angelo Spinazzola,&nbsp;Giuseppe Guzzardi,&nbsp;Francesco Intrieri,&nbsp;Daniele Savio,&nbsp;Giancarlo Palasciano","doi":"10.23736/S0021-9509.23.12668-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Penumbra/Indigo aspiration thrombectomy Systems (Penumbra Inc.) in patients with acute lower limb ischemia (ALLI) is becoming a fundamental alternative to surgical and intra-arterial thrombolysis. The INDIAN UP trial represents the second phase of the Italian national multicenter trial evaluating the safety and effectiveness of the device in the treatment of ALLI.</p><p><strong>Methods: </strong>To assess vessel patency, the TIPI (Thrombo-aspiration In Peripheral Ischemia), is used. The TIPI flow in three different moments: at presentation, immediately after thromboaspiration, and after all adjuvant procedures. The primary outcome is the technical success of the thrombo-aspiration with the investigative system, defined as near complete or complete revascularization TIPI 2 - 3. Safety and clinical success rate were collected at one month follow-up.</p><p><strong>Results: </strong>A total of 250 patients were enrolled. The mean age was 72.2±13.1 years and 72.1% were male. Rutherford grade on enrolment was I in 10.8%, IIa in 34.9%, and IIb in 54.4%. Primary technical success (TIPI 2-3 flow) was achieved in 90.8% of patients. Adjunctive procedures were needed in 158 cases. After all interventions, assisted primary technical success was 96.4%. No systemic bleeding complications or device related serious adverse events were reported. At one month follow up, survival rate was 97.2%, limb salvage was 97.6%. Primary patency was 89.6% and 13 (5.4%) reinterventions were registered.</p><p><strong>Conclusions: </strong>The updated results of the INDIAN UP trial have confirmed the high value of the mechanical thromboaspiration device Indigo Penumbra in the treatment of ALLI in a large variety of clinical and anatomical settings.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanical thrombectomy in acute limb ischemia: ad Interim results of the INDIAN UP Trial.\",\"authors\":\"Gianmarco de Donato,&nbsp;Edoardo Pasqui,&nbsp;Maria A Ruffino,&nbsp;Massimo Sponza,&nbsp;Angelo Spinazzola,&nbsp;Giuseppe Guzzardi,&nbsp;Francesco Intrieri,&nbsp;Daniele Savio,&nbsp;Giancarlo Palasciano\",\"doi\":\"10.23736/S0021-9509.23.12668-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Penumbra/Indigo aspiration thrombectomy Systems (Penumbra Inc.) in patients with acute lower limb ischemia (ALLI) is becoming a fundamental alternative to surgical and intra-arterial thrombolysis. The INDIAN UP trial represents the second phase of the Italian national multicenter trial evaluating the safety and effectiveness of the device in the treatment of ALLI.</p><p><strong>Methods: </strong>To assess vessel patency, the TIPI (Thrombo-aspiration In Peripheral Ischemia), is used. The TIPI flow in three different moments: at presentation, immediately after thromboaspiration, and after all adjuvant procedures. The primary outcome is the technical success of the thrombo-aspiration with the investigative system, defined as near complete or complete revascularization TIPI 2 - 3. Safety and clinical success rate were collected at one month follow-up.</p><p><strong>Results: </strong>A total of 250 patients were enrolled. The mean age was 72.2±13.1 years and 72.1% were male. Rutherford grade on enrolment was I in 10.8%, IIa in 34.9%, and IIb in 54.4%. Primary technical success (TIPI 2-3 flow) was achieved in 90.8% of patients. Adjunctive procedures were needed in 158 cases. After all interventions, assisted primary technical success was 96.4%. No systemic bleeding complications or device related serious adverse events were reported. At one month follow up, survival rate was 97.2%, limb salvage was 97.6%. Primary patency was 89.6% and 13 (5.4%) reinterventions were registered.</p><p><strong>Conclusions: </strong>The updated results of the INDIAN UP trial have confirmed the high value of the mechanical thromboaspiration device Indigo Penumbra in the treatment of ALLI in a large variety of clinical and anatomical settings.</p>\",\"PeriodicalId\":50245,\"journal\":{\"name\":\"Journal of Cardiovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S0021-9509.23.12668-1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.23.12668-1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:急性下肢缺血(ALLI)患者的半影/靛蓝吸入性取栓系统(Penumbra Inc.)正在成为手术和动脉溶栓的基本替代方案。印度UP试验是意大利国家多中心试验的第二阶段,该试验旨在评估该装置治疗ALLI的安全性和有效性。方法:采用TIPI(外周缺血血栓抽吸法)评估血管通畅程度。TIPI流量在三个不同的时刻:在呈现,血栓吸出后立即,并在所有辅助程序后。主要结果是血栓抽吸与调查系统的技术成功,定义为接近完全或完全血运重建TIPI 2 - 3。随访1个月收集安全性和临床成功率。结果:共纳入250例患者。平均年龄72.2±13.1岁,男性占72.1%。卢瑟福入学成绩为I的占10.8%,IIa的占34.9%,IIb的占54.4%。90.8%的患者获得了初步技术成功(TIPI 2-3流)。158例需要辅助手术。在所有干预措施后,辅助初级技术成功率为96.4%。无全身性出血并发症或器械相关的严重不良事件报道。随访1个月,生存率97.2%,残肢保留率97.6%。初次通畅率为89.6%,再干预13例(5.4%)。结论:印度UP试验的最新结果证实了机械血栓抽吸装置靛蓝半影在各种临床和解剖环境中治疗ALLI的高价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mechanical thrombectomy in acute limb ischemia: ad Interim results of the INDIAN UP Trial.

Background: Penumbra/Indigo aspiration thrombectomy Systems (Penumbra Inc.) in patients with acute lower limb ischemia (ALLI) is becoming a fundamental alternative to surgical and intra-arterial thrombolysis. The INDIAN UP trial represents the second phase of the Italian national multicenter trial evaluating the safety and effectiveness of the device in the treatment of ALLI.

Methods: To assess vessel patency, the TIPI (Thrombo-aspiration In Peripheral Ischemia), is used. The TIPI flow in three different moments: at presentation, immediately after thromboaspiration, and after all adjuvant procedures. The primary outcome is the technical success of the thrombo-aspiration with the investigative system, defined as near complete or complete revascularization TIPI 2 - 3. Safety and clinical success rate were collected at one month follow-up.

Results: A total of 250 patients were enrolled. The mean age was 72.2±13.1 years and 72.1% were male. Rutherford grade on enrolment was I in 10.8%, IIa in 34.9%, and IIb in 54.4%. Primary technical success (TIPI 2-3 flow) was achieved in 90.8% of patients. Adjunctive procedures were needed in 158 cases. After all interventions, assisted primary technical success was 96.4%. No systemic bleeding complications or device related serious adverse events were reported. At one month follow up, survival rate was 97.2%, limb salvage was 97.6%. Primary patency was 89.6% and 13 (5.4%) reinterventions were registered.

Conclusions: The updated results of the INDIAN UP trial have confirmed the high value of the mechanical thromboaspiration device Indigo Penumbra in the treatment of ALLI in a large variety of clinical and anatomical settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
7.10%
发文量
204
审稿时长
4-8 weeks
期刊介绍: The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.
期刊最新文献
Subclavian artery revascularization with subclavian-carotid transposition for TEVAR and non-TEVAR patients. Current perspectives in acute type B aortic dissections: a literature review. Long-term outcomes of thoracic endovascular aortic repair for the treatment of descending thoracic aortic aneurysms: a systematic review and meta-analysis. Outcomes of Omniflow® II prosthesis used for revascularization in the femoral tract both in infected and non-infected setting. Frozen elephant trunk technique for aortic arch surgery: the Bordeaux University Hospital experience with Thoraflex hybrid prosthesis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1