用于经导管主动脉瓣植入术中主动脉瓣环尺寸的自动化和半自动化3D超声心动图软件有助于弥合专家和新手之间的差距。

IF 1.5 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS International Journal of Cardiovascular Imaging Pub Date : 2023-09-01 Epub Date: 2023-08-12 DOI:10.1007/s10554-023-02885-z
Charles Massie, Martine Parent, Maxime Berthelot-Richer, Rémi Kouz, Donald Palisaitis, Viet Le, Frédéric Poulin
{"title":"用于经导管主动脉瓣植入术中主动脉瓣环尺寸的自动化和半自动化3D超声心动图软件有助于弥合专家和新手之间的差距。","authors":"Charles Massie,&nbsp;Martine Parent,&nbsp;Maxime Berthelot-Richer,&nbsp;Rémi Kouz,&nbsp;Donald Palisaitis,&nbsp;Viet Le,&nbsp;Frédéric Poulin","doi":"10.1007/s10554-023-02885-z","DOIUrl":null,"url":null,"abstract":"<p><p>3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"1707-1717"},"PeriodicalIF":1.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520092/pdf/","citationCount":"0","resultStr":"{\"title\":\"Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators.\",\"authors\":\"Charles Massie,&nbsp;Martine Parent,&nbsp;Maxime Berthelot-Richer,&nbsp;Rémi Kouz,&nbsp;Donald Palisaitis,&nbsp;Viet Le,&nbsp;Frédéric Poulin\",\"doi\":\"10.1007/s10554-023-02885-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.</p>\",\"PeriodicalId\":50332,\"journal\":{\"name\":\"International Journal of Cardiovascular Imaging\",\"volume\":\" \",\"pages\":\"1707-1717\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520092/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Cardiovascular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10554-023-02885-z\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Cardiovascular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10554-023-02885-z","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

3D经食管超声心动图(3D-TEE)是多探测器行计算机断层扫描(MDCT)的替代品,用于主动脉瓣环(AoA)的尺寸测量,为经导管主动脉瓣植入(TAVI)做准备。我们的目的是评估全自动(自动)和半自动(SA)TEE方法与传统手动TEE方法和黄金标准MDCT在专家和新手操作员中的环空尺寸测量方面的表现。在这项前瞻性队列研究中,89名严重主动脉狭窄患者接受了3D-TEE和MDCT的多模态成像。超声心动图专家使用3D自动、SA和手动方法收集环形测量值,并与MDCT进行比较。超声心动图领域的一位新手使用相同的方法对所有患者的AoA进行了回顾性测量。TEE测量与所用方法无关,与MDCT有很好的一致性。与MDCT相比,他们显著低估了主动脉环面积和周长,自动方法低估的最多,手动方法低估的最少(面积和周长分别为6.5%和1.3%)。对于专家来说,手动TEE方法提供的系统偏差最小,而SA方法的一致性限度(LOA)较窄。对于新手操作员来说,SA方法与MDCT相比提供了最小的偏差和较窄的LOA。新手和专家对所有3种TEE方法都有很好的一致性,但与手动方法相比,自动和SA方法的一致性更好。我们的研究支持使用3D-TEE作为MDCT的补充方法来确定主动脉环大小。更新的auto和SA软件需要最少的操作员干预,对于经验丰富的操作员,尤其是经验不足的操作员来说,它是一种易于使用、可靠且可重复的主动脉瓣环尺寸测量工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators.

3D-transesophageal echocardiography (3D-TEE) is an alternative to multidetector row computed tomography (MDCT) for aortic annulus (AoA) sizing in preparation for Transcatheter aortic valve implantation (TAVI). We aim to evaluate how the fully automated (auto) and semi-automated (SA) TEE methods perform compared to conventional manual TEE method and the gold standard MDCT for annulus sizing both in expert and novice operators. In this prospective cohort study, eighty-nine patients with severe aortic stenosis underwent multimodality imaging with 3D-TEE and MDCT. Annular measurements were collected by expert echocardiographers using 3D auto, SA and manual methods and compared to MDCT. A novice in the field of echocardiography retrospectively measured the AoA for all patients using the same methods. TEE measurements, independently of the method used, had good to very good agreement to MDCT. They significantly underestimated aortic annular area and circumference vs. MDCT with the auto method underestimating it the most and the manual method the least (6.5% and 1.3% respectively for area and circumference). For experts, the manual TEE method offered the least systematic bias while the SA method had narrower limits of agreement (LOA). For the novice operator, SA method provided the least bias and narrower LOA vs. MDCT. There is good agreement between novice and experts for all 3 TEE methods but better agreement with auto and SA methods as opposed to manual one. Our study supports the use of 3D-TEE as a complementary method to MDCT for aortic annular sizing. The newer auto and SA software, that requires minimal operator intervention, is an easy to use, reliable and reproducible tool for aortic annulus sizing for experienced operators, and especially less experienced ones.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.00
自引率
9.50%
发文量
77
审稿时长
1 months
期刊介绍: The International Journal of Cardiovascular Imaging publishes technical and clinical communications (original articles, review articles and editorial comments) associated with cardiovascular diseases. The technical communications include the research, development and evaluation of novel imaging methods in the various imaging domains. These domains include magnetic resonance imaging, computed tomography, X-ray imaging, intravascular imaging, and applications in nuclear cardiology and echocardiography, and any combination of these techniques. Of particular interest are topics in medical image processing and image-guided interventions. Clinical applications of such imaging techniques include improved diagnostic approaches, treatment , prognosis and follow-up of cardiovascular patients. Topics include: multi-center or larger individual studies dealing with risk stratification and imaging utilization, applications for better characterization of cardiovascular diseases, and assessment of the efficacy of new drugs and interventional devices.
期刊最新文献
Usefulness of three-dimensional pulmonary vein-left atrium image reconstructed from non-enhanced computed tomography for atrial fibrillation ablation. Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography. Evaluation of an artificial intelligence-based system for echocardiographic estimation of right atrial pressure. Strain Echocardiography in Myocarditis with preserved left ventricular function. The prognostic value of coronary flow reserve in patients with non-obstructive coronary artery disease and microvascular dysfunction: a systematic review and meta-analysis with focus on imaging modality and sex difference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1