一种新型脂肪肝治疗剂中杂质的鉴定与测定。

IF 2.3 3区 化学 Q3 CHEMISTRY, ANALYTICAL Journal of Analytical Methods in Chemistry Pub Date : 2023-01-01 DOI:10.1155/2023/3116223
Huihui Shao, Jing Feng, Hanyilan Zhang, Yuanyuan Zhang, Tong Qin, Yuhua Hu, Wenxuan Zhang, Tiesong Wang, Song Wu, Qingyun Yang
{"title":"一种新型脂肪肝治疗剂中杂质的鉴定与测定。","authors":"Huihui Shao,&nbsp;Jing Feng,&nbsp;Hanyilan Zhang,&nbsp;Yuanyuan Zhang,&nbsp;Tong Qin,&nbsp;Yuhua Hu,&nbsp;Wenxuan Zhang,&nbsp;Tiesong Wang,&nbsp;Song Wu,&nbsp;Qingyun Yang","doi":"10.1155/2023/3116223","DOIUrl":null,"url":null,"abstract":"<p><p>Methyl 7,7'-dimethoxy-5'-(morpholinomethyl)-[4,4'-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities I-IV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.1-2.0 <i>μ</i>g/mL for impurities I-IV and 0.3-30.0 ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05 ng/mL and 0.005 <i>μ</i>g/mL for impurity V and impurities I-IV, respectively. The precision and repeatability of the methods were less than 1.08% and 8.72% for each impurity. The recovery percentages of all impurities were in the range of 91.18%-111.27%, with the relative standard deviation of less than 3.69%. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.</p>","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421711/pdf/","citationCount":"0","resultStr":"{\"title\":\"Identification and Determination of Impurities in a New Therapeutic Agent for Fatty Liver Disease.\",\"authors\":\"Huihui Shao,&nbsp;Jing Feng,&nbsp;Hanyilan Zhang,&nbsp;Yuanyuan Zhang,&nbsp;Tong Qin,&nbsp;Yuhua Hu,&nbsp;Wenxuan Zhang,&nbsp;Tiesong Wang,&nbsp;Song Wu,&nbsp;Qingyun Yang\",\"doi\":\"10.1155/2023/3116223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Methyl 7,7'-dimethoxy-5'-(morpholinomethyl)-[4,4'-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities I-IV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.1-2.0 <i>μ</i>g/mL for impurities I-IV and 0.3-30.0 ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05 ng/mL and 0.005 <i>μ</i>g/mL for impurity V and impurities I-IV, respectively. The precision and repeatability of the methods were less than 1.08% and 8.72% for each impurity. The recovery percentages of all impurities were in the range of 91.18%-111.27%, with the relative standard deviation of less than 3.69%. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.</p>\",\"PeriodicalId\":14974,\"journal\":{\"name\":\"Journal of Analytical Methods in Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421711/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Methods in Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/3116223\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Methods in Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2023/3116223","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

甲基7,7'-二甲氧基-5'-(morpholinomethyl)-[4,4'-双苯并[d][1,3]二恶唑]-5-羧酸甲磺酸盐(IMM)是一种高效低毒的治疗非酒精性脂肪肝(NAFLD)的创新药物。本研究利用光谱学证据、化学合成方法和液相色谱-串联质谱(LC-MS/MS)对5种微量杂质(I、II、III、IV和V)进行了鉴定和分析。杂质包括从药物最终配方和合成过程中提取的水解物和氧化副产物。毒性预测显示含有n -氧片段的杂质V具有潜在的致癌性。建立并优化了一种可靠、选择性的高效液相色谱法(HPLC)定量分析杂质I-IV和一种灵敏的高效液相色谱-质谱联用法(HPLC-MS/MS)检测潜在遗传毒性杂质V。这些方法是根据国际协调理事会的准则进行验证的。杂质I-IV在0.1 ~ 2.0 μg/mL范围内,杂质V在0.3 ~ 30.0 ng/mL范围内线性良好,拟合相关系数均超过0.999。杂质V和杂质I-IV的检出限分别为0.05 ng/mL和0.005 μg/mL。方法的精密度和重复性分别小于1.08%和8.72%。各杂质回收率在91.18% ~ 111.27%范围内,相对标准偏差小于3.69%。采用AGREE软件对HPLC法和HPLC-MS/MS法进行绿度评价,评分值分别为0.72和0.68。所推荐的方法准确、特异、环保,并应用于IMM现有的活性药物成分,取得了满意的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Identification and Determination of Impurities in a New Therapeutic Agent for Fatty Liver Disease.

Methyl 7,7'-dimethoxy-5'-(morpholinomethyl)-[4,4'-bibenzo[d][1,3] dioxole]-5-carboxylate methanesulfonate (IMM) is an innovative drug for the treatment of nonalcoholic fatty liver disease (NAFLD) owing to its high efficacy and low toxicity. In this study, five minor impurities (I, II, III, IV, and V) were identified and analyzed using spectroscopic evidence, chemical synthetic methods, and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The impurities included hydrolysates and oxidation by-products extracted from both the drug in its final formulation and during synthesis. Toxicity prediction revealed potential carcinogenicity of impurity V containing an N-oxygen fragment. A reliable and selective HPLC method for the quantitative analysis of impurities I-IV and a sensitive HPLC-MS/MS method for potential genotoxic impurity V were developed and optimized. The methods were validated based on the International Council for Harmonization guidelines. Satisfactory linearity was obtained for the analytes over the range of 0.1-2.0 μg/mL for impurities I-IV and 0.3-30.0 ng/mL for impurity V, and in all cases, the fitting correlation coefficients exceeded 0.999. The obtained limits of detection values were 0.05 ng/mL and 0.005 μg/mL for impurity V and impurities I-IV, respectively. The precision and repeatability of the methods were less than 1.08% and 8.72% for each impurity. The recovery percentages of all impurities were in the range of 91.18%-111.27%, with the relative standard deviation of less than 3.69%. The greenness assessment of the HPLC method and the HPLC-MS/MS method were evaluated by using AGREE software with a score value of 0.72 and 0.68, respectively. The recommended procedures that were accurate, specific, and ecofriendly were applied to the existing active pharmaceutical ingredients of IMM, and they generated satisfactory results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Analytical Methods in Chemistry
Journal of Analytical Methods in Chemistry CHEMISTRY, ANALYTICAL-ENGINEERING, CIVIL
CiteScore
4.80
自引率
3.80%
发文量
79
审稿时长
6-12 weeks
期刊介绍: Journal of Analytical Methods in Chemistry publishes papers reporting methods and instrumentation for chemical analysis, and their application to real-world problems. Articles may be either practical or theoretical. Subject areas include (but are by no means limited to): Separation Spectroscopy Mass spectrometry Chromatography Analytical Sample Preparation Electrochemical analysis Hyphenated techniques Data processing As well as original research, Journal of Analytical Methods in Chemistry also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.
期刊最新文献
Handgrip-Ring Structure Sensing Probe Assisted Multiple Signal Amplification Strategy for Sensitive and Label-Free Single-Stranded Nucleic Acid Analysis. Characterization of Volatile Organic Compounds and Aroma Sensory Properties in Yunnan Cigar. H-Type Indices With Applications in Chemometrics: h-Accuracy Index for Evaluating and Comparing Errors in Analytical Chemistry. Screening Antioxidant Components in Yiwei Decoction Using Spectrum-Effect Relationship and Network Pharmacology. Electrochemical Analysis of Methanol with Nafion-Coated Copper Oxide Nanoparticles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1