Predicted overbite and overjet changes with the Invisalign appliance: a validation study.

IF 3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Angle Orthodontist Pub Date : 2024-01-01 DOI:10.2319/041323-269.1
Maurice J Meade, Haylea Blundell, Tony Weir
{"title":"Predicted overbite and overjet changes with the Invisalign appliance: a validation study.","authors":"Maurice J Meade, Haylea Blundell, Tony Weir","doi":"10.2319/041323-269.1","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate whether the predicted changes in overbite (OB) and overjet (OJ) in Align Technology's (Santa Jose, Calif) digital treatment plan for the prescribed course of treatment with the Invisalign appliance were consistent with those same changes in OB and OJ measured with the Geomagic Control X (Geomagic US, Research, Triangle Park, NC) metrology software system.</p><p><strong>Materials and methods: </strong>Geomagic Control X software was used to determine OB and OJ differences between the pretreatment and predicted outcome. STL files for patients satisfying inclusion criteria and undergoing nonextraction orthodontic treatment with the Invisalign appliance. The differences were compared, using the Bland-Altman analysis, to the corresponding data provided by Align Technology's digital treatment-planning interface, ClinCheck.</p><p><strong>Results: </strong>Data regarding 76 adult patients who satisfied strict inclusion criteria were assessed. The Shapiro-Wilks test indicated normality (P > .05). The Bland-Altman analysis showed high levels of agreement between the two measurements, with a bias range of -0.131 to 0.111 for OB and -0.393 to 0.03 for OJ recorded.</p><p><strong>Conclusions: </strong>Clinicians and researchers can be confident that measurement data provided by Invisalign's ClinCheck digital treatment-planning facility concerning OB and OJ changes from the initial to the predicted treatment outcome are valid.</p>","PeriodicalId":50790,"journal":{"name":"Angle Orthodontist","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10928931/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Angle Orthodontist","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2319/041323-269.1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To investigate whether the predicted changes in overbite (OB) and overjet (OJ) in Align Technology's (Santa Jose, Calif) digital treatment plan for the prescribed course of treatment with the Invisalign appliance were consistent with those same changes in OB and OJ measured with the Geomagic Control X (Geomagic US, Research, Triangle Park, NC) metrology software system.

Materials and methods: Geomagic Control X software was used to determine OB and OJ differences between the pretreatment and predicted outcome. STL files for patients satisfying inclusion criteria and undergoing nonextraction orthodontic treatment with the Invisalign appliance. The differences were compared, using the Bland-Altman analysis, to the corresponding data provided by Align Technology's digital treatment-planning interface, ClinCheck.

Results: Data regarding 76 adult patients who satisfied strict inclusion criteria were assessed. The Shapiro-Wilks test indicated normality (P > .05). The Bland-Altman analysis showed high levels of agreement between the two measurements, with a bias range of -0.131 to 0.111 for OB and -0.393 to 0.03 for OJ recorded.

Conclusions: Clinicians and researchers can be confident that measurement data provided by Invisalign's ClinCheck digital treatment-planning facility concerning OB and OJ changes from the initial to the predicted treatment outcome are valid.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用隐适美矫正器预测咬合过度和咬合过紧的变化:一项验证研究。
目的研究 Align 技术公司(加利福尼亚州圣何塞)的数字化治疗计划中对隐适美矫正器规定疗程的咬合过度(OB)和咬合过高(OJ)的预测变化是否与 Geomagic Control X(Geomagic US,Research,Triangle Park,NC)计量软件系统测量的咬合过度和咬合过高的变化一致:使用 Geomagic Control X 软件确定治疗前与预测结果之间的 OB 和 OJ 差异。对符合纳入标准并使用隐适美(Invisalign)矫治器进行非拔牙正畸治疗的患者的 STL 文件进行分析。使用 Bland-Altman 分析法将差异与 Align Technology 的数字治疗规划界面 ClinCheck 提供的相应数据进行比较:对符合严格纳入标准的 76 名成年患者的数据进行了评估。Shapiro-Wilks 检验表明数据呈正态性(P > .05)。Bland-Altman分析表明,两种测量结果的一致性很高,OB的偏差范围为-0.131至0.111,OJ的偏差范围为-0.393至0.03:临床医生和研究人员可以确信,隐适美 ClinCheck 数字化治疗规划设备提供的有关从初始治疗结果到预测治疗结果的 OB 和 OJ 变化的测量数据是有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Angle Orthodontist
Angle Orthodontist 医学-牙科与口腔外科
CiteScore
6.40
自引率
5.90%
发文量
95
审稿时长
3 months
期刊介绍: The Angle Orthodontist is the official publication of the Edward H. Angle Society of Orthodontists and is published bimonthly in January, March, May, July, September and November by The EH Angle Education and Research Foundation Inc. The Angle Orthodontist is the only major journal in orthodontics with a non-commercial, non-profit publisher -- The E. H. Angle Education and Research Foundation. We value our freedom to operate exclusively in the best interests of our readers and authors. Our website www.angle.org is completely free and open to all visitors.
期刊最新文献
Does clinical experience affect the bracket bonding accuracy of guided bonding devices in vitro? Digitization and validation of the open bite checklist manifesto: a step toward artificial intelligence. The effect of vertical skeletal proportions on overbite changes in untreated adolescents: a longitudinal evaluation. Predicted overbite and overjet changes with the Invisalign appliance: a validation study. Responsiveness of three measurements in cone-beam computed tomography transverse analyses during both tooth-supported and mini-screw-assisted rapid maxillary expansion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1