{"title":"Usability of mixed reality in awake craniotomy planning.","authors":"Richard D C Moon, Neil U Barua","doi":"10.1080/02688697.2022.2152429","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to describe our institutional use of a commercially available mixed reality viewer within a multi-disciplinary planning workflow for awake craniotomy surgery and to report an assessment of its usability.</p><p><strong>Materials and methods: </strong>Three Tesla MRI scans, including 32-direction diffusion tensor sequences, were reconstructed with BrainLab Elements auto-segmentation software. Magic Leap mixed reality viewer headsets were registered to a shared virtual viewing space to display image reconstructions. System Usability Scale was used to assess the usability of the mixed reality system.</p><p><strong>Results: </strong>The awake craniotomy planning workflow utilises the mixed reality viewer to facilitate a stepwise discussion through four progressive anatomical layers; the skin, cerebral cortex, subcortical white matter tracts and tumour with surrounding vasculature. At each stage relevant members of the multi-disciplinary team review key operative considerations, including patient positioning, cortical and subcortical speech mapping protocols and surgical approaches to the tumour.The mixed reality system was used for multi-disciplinary awake craniotomy planning in 10 consecutive procedures over a 5-month period. Ten participants (2 Anaesthetists, 5 Neurosurgical trainees, 2 Speech therapists, 1 Neuropsychologist) completed System Usability Scale assessments, reporting a mean score of 71.5. Feedback highlighted the benefit of being able to rehearse important steps in the procedure, including patient positioning and anaesthetic access and visualising the testing protocol for cortical and subcortical speech mapping.</p><p><strong>Conclusions: </strong>This study supports the use of mixed reality for multidisciplinary planning for awake craniotomy surgery, with an acceptable degree of usability of the interface. We highlight the need to consider the requirements of non-technical, non-neurosurgical team members when involving mixed reality activities.</p>","PeriodicalId":9261,"journal":{"name":"British Journal of Neurosurgery","volume":" ","pages":"1139-1143"},"PeriodicalIF":1.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02688697.2022.2152429","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/12/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aimed to describe our institutional use of a commercially available mixed reality viewer within a multi-disciplinary planning workflow for awake craniotomy surgery and to report an assessment of its usability.
Materials and methods: Three Tesla MRI scans, including 32-direction diffusion tensor sequences, were reconstructed with BrainLab Elements auto-segmentation software. Magic Leap mixed reality viewer headsets were registered to a shared virtual viewing space to display image reconstructions. System Usability Scale was used to assess the usability of the mixed reality system.
Results: The awake craniotomy planning workflow utilises the mixed reality viewer to facilitate a stepwise discussion through four progressive anatomical layers; the skin, cerebral cortex, subcortical white matter tracts and tumour with surrounding vasculature. At each stage relevant members of the multi-disciplinary team review key operative considerations, including patient positioning, cortical and subcortical speech mapping protocols and surgical approaches to the tumour.The mixed reality system was used for multi-disciplinary awake craniotomy planning in 10 consecutive procedures over a 5-month period. Ten participants (2 Anaesthetists, 5 Neurosurgical trainees, 2 Speech therapists, 1 Neuropsychologist) completed System Usability Scale assessments, reporting a mean score of 71.5. Feedback highlighted the benefit of being able to rehearse important steps in the procedure, including patient positioning and anaesthetic access and visualising the testing protocol for cortical and subcortical speech mapping.
Conclusions: This study supports the use of mixed reality for multidisciplinary planning for awake craniotomy surgery, with an acceptable degree of usability of the interface. We highlight the need to consider the requirements of non-technical, non-neurosurgical team members when involving mixed reality activities.
期刊介绍:
The British Journal of Neurosurgery is a leading international forum for debate in the field of neurosurgery, publishing original peer-reviewed articles of the highest quality, along with comment and correspondence on all topics of current interest to neurosurgeons worldwide.
Coverage includes all aspects of case assessment and surgical practice, as well as wide-ranging research, with an emphasis on clinical rather than experimental material. Special emphasis is placed on postgraduate education with review articles on basic neurosciences and on the theory behind advances in techniques, investigation and clinical management. All papers are submitted to rigorous and independent peer-review, ensuring the journal’s wide citation and its appearance in the major abstracting and indexing services.