Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings

G. Stone, J. Kapler
{"title":"Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings","authors":"G. Stone, J. Kapler","doi":"10.1109/CITCON.1997.599162","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) tests can determine which motor and generator stator windings are experiencing insulation problems. A deteriorated winding has a PD activity which can be 30 times or more higher than a winding in good condition. This great difference in PD activity enables even nonspecialized maintenance personnel to identify the few motors or generators in a company which need further investigation and/or maintenance. After implementing on-line partial discharge tests companies can often confidently extend the outage between major machine inspections. This saves on outage costs and reduces the risk of a stator fault due to human error during maintenance. Finally, on older machines, if there has been no increase in partial discharge activity over time, then the life of the stator winding can be confidently extended, saving a considerable capital expenditure. The PD tests discussed cost virtually nothing to perform, once the sensors are installed, since existing company staff can do the tests in about 30 minutes during normal motor or generator operation.","PeriodicalId":443254,"journal":{"name":"1997 IEEE/PCA Cement Industry Technical Conference. XXXIX Conference Record (Cat. No.97CH36076)","volume":"34 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE/PCA Cement Industry Technical Conference. XXXIX Conference Record (Cat. No.97CH36076)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CITCON.1997.599162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Partial discharge (PD) tests can determine which motor and generator stator windings are experiencing insulation problems. A deteriorated winding has a PD activity which can be 30 times or more higher than a winding in good condition. This great difference in PD activity enables even nonspecialized maintenance personnel to identify the few motors or generators in a company which need further investigation and/or maintenance. After implementing on-line partial discharge tests companies can often confidently extend the outage between major machine inspections. This saves on outage costs and reduces the risk of a stator fault due to human error during maintenance. Finally, on older machines, if there has been no increase in partial discharge activity over time, then the life of the stator winding can be confidently extended, saving a considerable capital expenditure. The PD tests discussed cost virtually nothing to perform, once the sensors are installed, since existing company staff can do the tests in about 30 minutes during normal motor or generator operation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用局部放电测量技术对高压电机和发电机定子绕组进行预测性维护
局部放电(PD)测试可以确定哪些电机和发电机定子绕组出现绝缘问题。劣化绕组的PD活性可能比良好绕组高30倍或更多。PD活动的这种巨大差异使非专业维护人员能够识别公司中需要进一步调查和/或维护的少数电机或发电机。在实施在线局部放电测试后,公司通常可以自信地延长主要机器检查之间的停机时间。这节省了停机成本,并降低了由于维护期间人为错误而导致定子故障的风险。最后,在较旧的机器上,如果随着时间的推移,部分放电活动没有增加,那么定子绕组的寿命可以自信地延长,节省了相当大的资本支出。一旦安装了传感器,所讨论的PD测试几乎不需要任何成本,因为现有的公司员工可以在电机或发电机正常运行的情况下,在大约30分钟内完成测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings Starting high inertia loads on adjustable speed drives Design and engineering of a modern process control system ~for cement plants\ Applying DeviceNet in motor control centers at a cement plant Roller mill application for high moisture feed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1