{"title":"Transient modeling of transmission lines components with respect to corona phenomenon and grounding system to reduce the transient voltages caused by lightning Impulse","authors":"Ebadollah Amouzad Mahdiraji, N. Ramezani","doi":"10.1109/KBEI.2015.7436079","DOIUrl":null,"url":null,"abstract":"In this paper, the behavior of the grounding system at different frequencies has been investigated under lightning conditions with and without the corona phenomenon. Also using EMTP-RV software, a model of Corona with two different earth systems was constructed at the high voltage alternating current transmission line and the effect of soil resistance changes and corona pulses were shown in the voltage signals across the insulator and it was found that the corona phenomenon causes voltage signal attenuation and damping and increasing the wave front time, also it has been shown that the high-frequency grounding system has a higher validity than the low-frequency grounding system.","PeriodicalId":168295,"journal":{"name":"2015 2nd International Conference on Knowledge-Based Engineering and Innovation (KBEI)","volume":"307 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 2nd International Conference on Knowledge-Based Engineering and Innovation (KBEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/KBEI.2015.7436079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, the behavior of the grounding system at different frequencies has been investigated under lightning conditions with and without the corona phenomenon. Also using EMTP-RV software, a model of Corona with two different earth systems was constructed at the high voltage alternating current transmission line and the effect of soil resistance changes and corona pulses were shown in the voltage signals across the insulator and it was found that the corona phenomenon causes voltage signal attenuation and damping and increasing the wave front time, also it has been shown that the high-frequency grounding system has a higher validity than the low-frequency grounding system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑电晕现象和接地系统的输电线路组件暂态建模,以降低雷击脉冲引起的暂态电压
本文研究了在有和没有电晕现象的雷电条件下,接地系统在不同频率下的行为。同样利用EMTP-RV软件,在高压交流输电线上建立了两种不同接地系统下的电晕模型,分析了土壤电阻变化和电晕脉冲对绝缘子两端电压信号的影响,发现电晕现象导致电压信号衰减和阻尼,波前时间增加;结果表明,高频接地系统比低频接地系统具有更高的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Numerical investigation of water drop movement within a microchannel under electrowetting phenomenon An improvement on LEACH protocol (EZ-LEACH) Transient modeling of transmission lines components with respect to corona phenomenon and grounding system to reduce the transient voltages caused by lightning Impulse A modified digital to digital encoding method to improve the Wireless Body Area Network (WBAN) transmission Synchronization of chaotic Gyroscopes via an adaptive robust controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1