{"title":"Airgap Search Coil-Based Detection of Damper Bar Failures in Salient Pole Synchronous Motors","authors":"J. Yun, S. Park, C. Yang, S.B. Lee, J. Antonino-Daviu, M. Šašić, G. Stone","doi":"10.1109/ECCE.2018.8557640","DOIUrl":null,"url":null,"abstract":"Damper bars are often used in high output salient pole synchronous motor (SM) rotors for motor starting and stabilization of performance. Several cases of broken damper bars in the rotor of SMs that lead to motor starting failure and/or forced outage have recently been reported. However, detection of damper bar failures is difficult, since the damper bars are active only under the starting or load transients. Damper bar testing in the field currently relies on off-line visual inspection, and there is no means available for detecting failures on-line. In this paper, a new method for detecting damper bar failures based on the analysis of airgap search coil measurements under the starting transient is proposed. Since airgap search coils are being increasingly installed in large SMs for detecting field winding short circuits, the proposed method can be implemented without additional hardware. The effectiveness of the proposed method is verified with 2 dimensional finite element analysis and experimental testing on a custom-built 30 kW salient pole SM under controlled fault conditions. It is shown that the proposed method can provide reliable and sensitive detection of broken damper bars whenever the motor is started at low additional cost.","PeriodicalId":415217,"journal":{"name":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"372 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2018.8557640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

Damper bars are often used in high output salient pole synchronous motor (SM) rotors for motor starting and stabilization of performance. Several cases of broken damper bars in the rotor of SMs that lead to motor starting failure and/or forced outage have recently been reported. However, detection of damper bar failures is difficult, since the damper bars are active only under the starting or load transients. Damper bar testing in the field currently relies on off-line visual inspection, and there is no means available for detecting failures on-line. In this paper, a new method for detecting damper bar failures based on the analysis of airgap search coil measurements under the starting transient is proposed. Since airgap search coils are being increasingly installed in large SMs for detecting field winding short circuits, the proposed method can be implemented without additional hardware. The effectiveness of the proposed method is verified with 2 dimensional finite element analysis and experimental testing on a custom-built 30 kW salient pole SM under controlled fault conditions. It is shown that the proposed method can provide reliable and sensitive detection of broken damper bars whenever the motor is started at low additional cost.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于气隙搜索线圈的凸极同步电机阻尼杆故障检测
阻尼杆常用于高输出凸极同步电机转子,用于电机启动和性能稳定。最近报道了几起SMs转子阻尼杆断裂导致电机启动失败和/或强制停机的案例。然而,检测阻尼杆失效是困难的,因为阻尼杆只有在启动或负载瞬态下才有效。目前现场的阻尼杆测试依赖于离线目测,没有在线检测故障的手段。本文提出了一种基于起动瞬态下气隙搜索线圈测量分析的阻尼杆失效检测新方法。由于气隙搜索线圈越来越多地安装在大型SMs中用于检测场绕组短路,因此所提出的方法可以在没有额外硬件的情况下实现。通过二维有限元分析和定制的30kw凸极SM在可控故障条件下的实验测试,验证了该方法的有效性。结果表明,该方法能够在电机启动时可靠、灵敏地检测出阻尼杆的断裂,且附加成本低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Control Schemes for Reducing the Second Harmonic Current in Two-Stage Single-Phase Converter: An Overview from DC-Bus Port-Impedance Characterization Minimizing Reactive Current of a High Gain Dual Active Bridge Converter for Supercapacitor Based Energy Storage System Integration High Frequency Small Signal Model for Inverse Charge Constant On-Time (IQCOT) Control Airgap Search Coil-Based Detection of Damper Bar Failures in Salient Pole Synchronous Motors On-line Compensation of Periodic Error in Resolver Signals for PMSM Drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1