{"title":"Study on Line Detection and Fault Location with Automatic Track Arc Suppression Coil Device","authors":"Linshu Li, Luping Jiang","doi":"10.1109/ICPST.2006.321477","DOIUrl":null,"url":null,"abstract":"The correctness of common line detection devices with automatic arc suppression coil is not very high. In this paper, proposed a new way to detect line in automatic arc suppression coil network for single phase to ground fault based on the theory that the zero sequence admittance of the fault line before and after fault are variable , while the zero sequence admittance of the non-fault line before and after fault are constant. Thus we can detect the fault line. The zero sequence current of the fault line measured by FTU can be transmitted through distribution network automatic system to line detection device. The device calculates and judges every zone' s admittance of the fault line, and then the grounding fault zone can be located. To improve its reliability correcting method is also analyzed.","PeriodicalId":181574,"journal":{"name":"2006 International Conference on Power System Technology","volume":"43 12","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Conference on Power System Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPST.2006.321477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The correctness of common line detection devices with automatic arc suppression coil is not very high. In this paper, proposed a new way to detect line in automatic arc suppression coil network for single phase to ground fault based on the theory that the zero sequence admittance of the fault line before and after fault are variable , while the zero sequence admittance of the non-fault line before and after fault are constant. Thus we can detect the fault line. The zero sequence current of the fault line measured by FTU can be transmitted through distribution network automatic system to line detection device. The device calculates and judges every zone' s admittance of the fault line, and then the grounding fault zone can be located. To improve its reliability correcting method is also analyzed.