{"title":"Performance of a broadband acoustic Doppler current profiler","authors":"B. Brumley, R. Cabrera, K. Deines, E. Terray","doi":"10.1109/CURM.1990.110915","DOIUrl":null,"url":null,"abstract":"A broadband acoustic Doppler current profiler (ADCP) with enhanced performance is described. It has a useful range comparable to that of a commercially available narrowband system of the same acoustic frequency. The extra performance may be traded off among reduced velocity variance, reduced averaging time, and finer depth resolution. An expression predicting rms velocity error in terms of system parameters and the measured acoustic data is given and is shown to be consistent with the independently measured velocity error among redundant beams. The major source of bias error in narrowband ADCPs is shown to be greatly reduced for the broad band system.<<ETX>>","PeriodicalId":364128,"journal":{"name":"Proceedings of the IEEE Fourth Working Conference on Current Measurement","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the IEEE Fourth Working Conference on Current Measurement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CURM.1990.110915","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

A broadband acoustic Doppler current profiler (ADCP) with enhanced performance is described. It has a useful range comparable to that of a commercially available narrowband system of the same acoustic frequency. The extra performance may be traded off among reduced velocity variance, reduced averaging time, and finer depth resolution. An expression predicting rms velocity error in terms of system parameters and the measured acoustic data is given and is shown to be consistent with the independently measured velocity error among redundant beams. The major source of bias error in narrowband ADCPs is shown to be greatly reduced for the broad band system.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
宽带声学多普勒电流分析器的性能
介绍了一种性能增强的宽带声学多普勒电流谱仪(ADCP)。它的有用范围可与商用窄带系统的相同声波频率相媲美。额外的性能可以在减少的速度方差、减少的平均时间和更精细的深度分辨率之间进行权衡。给出了用系统参数和实测声学数据预测均方根速度误差的表达式,并证明该表达式与独立测量的冗余波束间速度误差是一致的。窄带adcp的主要偏置误差源在宽带系统中被大大减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring wave direction using upward-looking Doppler sonar Performance of a broadband acoustic Doppler current profiler Spatially-averaged velocity from the seafloor horizontal electric field A note on the response characteristics of the VACM compass Deployment of an acoustic Doppler current profiler using a low-drag subsurface multisensor flotation package: design criteria and results
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1