Life expectancy of high voltage bushings based on incipient failure detections: a practical approach

Luciano Enciso, José L. Martínez, P. Arce
{"title":"Life expectancy of high voltage bushings based on incipient failure detections: a practical approach","authors":"Luciano Enciso, José L. Martínez, P. Arce","doi":"10.1109/EIC47619.2020.9158690","DOIUrl":null,"url":null,"abstract":"Failures in HV bushings are responsible for the third part of major failures in HV power transformers and reactors, according to data available in different researches. Sometimes, bushing failures could have not impact as mayor failures and, as a consequence, these events are both, not registered nor taken into account to develop statistics. Detection of incipient failures sometimes are not neither registered. It results relevant to know the HV bushings life expectancy in order to define proactive actions with time enough before a major failure could occur as well as to prioritize the purchase of spare bushings for each model. In this work, criteria to recognize incipient failures in HV bushings is proposed. This is based on our own experience with field results of dissipation factor and capacitance measurements, tip-up test and frequency domain spectroscopy measurements over a population of more than 1000 HV bushings. Such criteria are compared against the existing ones in available bibliography. The life expectancy of HV bushings according with each method used are evaluated and compared every each other looking for if exists one of them which detect problems in an earlier way.","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC47619.2020.9158690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Failures in HV bushings are responsible for the third part of major failures in HV power transformers and reactors, according to data available in different researches. Sometimes, bushing failures could have not impact as mayor failures and, as a consequence, these events are both, not registered nor taken into account to develop statistics. Detection of incipient failures sometimes are not neither registered. It results relevant to know the HV bushings life expectancy in order to define proactive actions with time enough before a major failure could occur as well as to prioritize the purchase of spare bushings for each model. In this work, criteria to recognize incipient failures in HV bushings is proposed. This is based on our own experience with field results of dissipation factor and capacitance measurements, tip-up test and frequency domain spectroscopy measurements over a population of more than 1000 HV bushings. Such criteria are compared against the existing ones in available bibliography. The life expectancy of HV bushings according with each method used are evaluated and compared every each other looking for if exists one of them which detect problems in an earlier way.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于早期故障检测的高压套管预期寿命:一种实用方法
根据不同的研究数据,高压套管故障占高压电力变压器和电抗器主要故障的三分之一。有时,衬套故障可能不会像主要故障那样产生影响,因此,这些事件既没有被记录,也没有被考虑到统计数据中。早期故障的检测有时也不被记录。了解高压衬套的预期寿命是非常重要的,这样可以在重大故障发生之前有足够的时间确定主动行动,并为每种型号优先购买备用衬套。在这项工作中,提出了识别高压套管早期失效的标准。这是基于我们自己对1000多个高压套管的耗散系数和电容测量、倾卸测试和频域光谱测量的现场结果的经验。将这些标准与现有参考书目中的标准进行比较。根据所采用的各种方法对高压套管的寿命进行了评估和比较,寻找是否存在较早发现问题的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Onsite Testing and Diagnosis of Medium Voltage Resin Impregnated Paper (RIP) Insulated Buses by Using Very Low Frequency High Voltage Analysis and suggestion on the chromatographic detection of inverted oil immersed current transformer Detection of Partial Discharges Occurring in Propulsion Coils of Superconducting Maglev Systems from a Test Bogie Running at High Speed Using a Radio Interferometer System with a Vector-Antenna Life expectancy of high voltage bushings based on incipient failure detections: a practical approach Approaches to the forensic failure investigation of medium voltage polymeric cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1