{"title":"A Study of Radiated EMI Predictions from Measured Common-mode Currents for Switching Power Supplies","authors":"Warathep Padungtin, V. Tarateeraseth","doi":"10.1109/ECTI-CON49241.2020.9158271","DOIUrl":null,"url":null,"abstract":"In this paper, an effectiveness of the classical method proposed by Clayton R. Paul [1]-[3] for estimating radiated electromagnetic interference (EMI) from measured common-mode currents for switching power supply as a noise source is evaluated. The proposed radiated EMI prediction method by Clayton R. Paul [1]-[3] is compared with the testing results in the standard anechoic chamber in order to verify its effectiveness. From the experimental results, it can be concluded that the procedure to predict the radiated EMI of proposed method by [1]-[3] is easy to follow, and it needs only the measured common-mode current using the high-frequency clamp-on current probe. Although, this method can be used as a guideline for radiated EMI prediction, the accuracy of this method needs to be improved.","PeriodicalId":371552,"journal":{"name":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 17th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTI-CON49241.2020.9158271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, an effectiveness of the classical method proposed by Clayton R. Paul [1]-[3] for estimating radiated electromagnetic interference (EMI) from measured common-mode currents for switching power supply as a noise source is evaluated. The proposed radiated EMI prediction method by Clayton R. Paul [1]-[3] is compared with the testing results in the standard anechoic chamber in order to verify its effectiveness. From the experimental results, it can be concluded that the procedure to predict the radiated EMI of proposed method by [1]-[3] is easy to follow, and it needs only the measured common-mode current using the high-frequency clamp-on current probe. Although, this method can be used as a guideline for radiated EMI prediction, the accuracy of this method needs to be improved.
本文评估了Clayton R. Paul[1]-[3]经典方法对作为噪声源的开关电源共模电流辐射电磁干扰(EMI)估计的有效性。将Clayton R. Paul提出的[1]-[3]辐射电磁干扰预测方法与标准暗室的测试结果进行了比较,验证了该方法的有效性。实验结果表明,采用[1]-[3]法预测辐射电磁干扰的步骤简单易行,只需利用高频钳位电流探头测量共模电流即可。虽然该方法可以作为辐射电磁干扰预测的指导,但其精度有待提高。