Instrumentation with attoFarad resolution for electrochemical impedance measurements on molecular biosensors

M. Carminati, G. Ferrari, F. Gozzini, M. Sampietro
{"title":"Instrumentation with attoFarad resolution for electrochemical impedance measurements on molecular biosensors","authors":"M. Carminati, G. Ferrari, F. Gozzini, M. Sampietro","doi":"10.1109/RME.2009.5201360","DOIUrl":null,"url":null,"abstract":"Sub-attoFarad capacitance resolution is experimentally reached, demonstrating the suitability of the proposed instrumentation for the development of impedimetric molecular biosensors. The modular design of the system is illustrated along with novel analog solutions (providing high sensitivity over a DC-1MHz bandwidth), digital lock-in elaboration techniques and their impact on the final instrument resolution.","PeriodicalId":245992,"journal":{"name":"2009 Ph.D. Research in Microelectronics and Electronics","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Ph.D. Research in Microelectronics and Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RME.2009.5201360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sub-attoFarad capacitance resolution is experimentally reached, demonstrating the suitability of the proposed instrumentation for the development of impedimetric molecular biosensors. The modular design of the system is illustrated along with novel analog solutions (providing high sensitivity over a DC-1MHz bandwidth), digital lock-in elaboration techniques and their impact on the final instrument resolution.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分子生物传感器电化学阻抗测量用阿法拉分辨率仪器
实验达到亚阿法拉电容分辨率,证明了所提出的仪器对阻抗分子生物传感器发展的适用性。系统的模块化设计与新颖的模拟解决方案(在DC-1MHz带宽上提供高灵敏度)、数字锁定细化技术及其对最终仪器分辨率的影响一起进行了说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Instrumentation with attoFarad resolution for electrochemical impedance measurements on molecular biosensors Novel designs of recursive discrete-time sinusoidal oscillators Reduction of up-converted flicker noise in differential LC-VCO designed in 32nm CMOS technology Read range limitation in IF-based far-field RFID using ASK backscatter modulation The effect of redundancy on mismatch-induced offset and random noise in a dynamic comparator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1