{"title":"Novel designs of digital detection analyzer for intelligent detection and analysis in digital microfluidic biochips","authors":"P. Roy, M. R. Patra, H. Rahaman, P. Dasgupta","doi":"10.1109/IDT.2013.6727133","DOIUrl":null,"url":null,"abstract":"A second generation lab-on-chip device termed as digital microfluidic biochip is developed as a time-multiplexed reconfigurable device capable of executing multiple bioassay protocols simultaneously on a single 2D planar array. They combine biology with electronics and integrate various bioassay operations namely sample preparation, analysis, separation and detection. Optical detection, processing and analysis are considered to be of major significance as these may influence the decisions on diagnosis, detection and testing. In this paper we initially propose two separate circuit designs of digital detection analyzer to be coupled with a biochip for execution of prescheduled bioassay protocols. The two types of analyzers enable automated detailed analysis of the optical detection results based on the data acquired at the detection site through successful Biochip operation for a) homogeneous droplet samples and b) heterogeneous droplet samples. A third circuit that integrates the previous two designs for dual mode operation is also proposed. Synthesis and simulation of all the three proposed designs are carried out using pre-characterized reference data for measurement of different parameters of human blood samples and the corresponding final detection results are displayed and verified successfully.","PeriodicalId":446826,"journal":{"name":"2013 8th IEEE Design and Test Symposium","volume":"2020 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 8th IEEE Design and Test Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IDT.2013.6727133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A second generation lab-on-chip device termed as digital microfluidic biochip is developed as a time-multiplexed reconfigurable device capable of executing multiple bioassay protocols simultaneously on a single 2D planar array. They combine biology with electronics and integrate various bioassay operations namely sample preparation, analysis, separation and detection. Optical detection, processing and analysis are considered to be of major significance as these may influence the decisions on diagnosis, detection and testing. In this paper we initially propose two separate circuit designs of digital detection analyzer to be coupled with a biochip for execution of prescheduled bioassay protocols. The two types of analyzers enable automated detailed analysis of the optical detection results based on the data acquired at the detection site through successful Biochip operation for a) homogeneous droplet samples and b) heterogeneous droplet samples. A third circuit that integrates the previous two designs for dual mode operation is also proposed. Synthesis and simulation of all the three proposed designs are carried out using pre-characterized reference data for measurement of different parameters of human blood samples and the corresponding final detection results are displayed and verified successfully.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
数字微流控生物芯片智能检测分析的新型数字检测分析仪设计
第二代实验室芯片设备称为数字微流控生物芯片是一种时间复用可重构设备,能够在单个二维平面阵列上同时执行多种生物测定方案。它们将生物学与电子学相结合,整合了各种生物测定操作,即样品制备、分析、分离和检测。光学检测、处理和分析被认为具有重要意义,因为它们可能影响诊断、检测和测试的决策。在本文中,我们初步提出了两种独立的电路设计,将数字检测分析仪与生物芯片相结合,以执行预定的生物测定方案。这两种类型的分析仪能够根据通过成功的Biochip操作在检测现场获得的数据对光学检测结果进行自动化的详细分析,这些数据分别用于a)均匀液滴样品和b)非均匀液滴样品。第三种电路集成了前两种设计的双模式工作也被提出。利用预表征参考数据对人体血液样品的不同参数进行了综合仿真,并成功展示了相应的最终检测结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assertion based on-line fault detection applied on UHF RFID tag Evaluation of the angle of arrival based techniques Novel designs of digital detection analyzer for intelligent detection and analysis in digital microfluidic biochips Systolic architecture for hardware implementation of two-dimensional non-separable filter-bank Compilation optimization exploration for thermal dissipation reduction in embedded systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1