Novel biosensing devices for medical applications Soft contact-lens sensors for monitoring tear sugar

K. Mitsubayashi
{"title":"Novel biosensing devices for medical applications Soft contact-lens sensors for monitoring tear sugar","authors":"K. Mitsubayashi","doi":"10.1109/SISPAD.2014.6931635","DOIUrl":null,"url":null,"abstract":"A soft contact-lens amperometric glucose sensor as novel non-invasive device of body sensor network was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode, which was fabricated using “Soft-MEMS” techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.039-0.537 mmol/l. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.2 mmol/l to 0.5 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.","PeriodicalId":101858,"journal":{"name":"2014 International Conference on Simulation of Semiconductor Processes and Devices (SISPAD)","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Simulation of Semiconductor Processes and Devices (SISPAD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SISPAD.2014.6931635","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A soft contact-lens amperometric glucose sensor as novel non-invasive device of body sensor network was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode, which was fabricated using “Soft-MEMS” techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.039-0.537 mmol/l. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.2 mmol/l to 0.5 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于医疗应用的新型生物传感装置监测泪糖的软性隐形眼镜传感器
制作并测试了一种新型的无创体感测网络装置——软性接触镜式安培葡萄糖传感器。此外,该传感器还用于撕裂血糖监测。该传感器是通过将GOD固定在柔性氧电极上构建的,而柔性氧电极是用“软mems”技术在功能聚合物膜上制造的。在生物仪器中,不使用粘接剂来构建柔性生物传感器。葡萄糖浓度与输出电流在0.039 ~ 0.537 mmol/l范围内呈线性关系。电流对pH和温度的依赖性也进行了评估。pH 7.0时电流最大,温度升高电流增大。这表明输出电流取决于酶的活性。在基本特性研究的基础上,将葡萄糖传感器应用于日本大白兔眼部位泪液中葡萄糖的测定。口服葡萄糖引起的泪液葡萄糖水平的变化是通过附着在眼睛部位的传感器的电流变化来监测的。在本研究中,泪液葡萄糖水平从0.2 mmol/l到0.5 mmol/l不等。虽然对血糖水平有几十分钟的延迟,但使用柔性生物传感器可以实现无创连续血糖监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Physics of electronic transport in low-dimensionality materials for future FETs Effects of carbon-related oxide defects on the reliability of 4H-SiC MOSFETs Challenge of adopting TCAD in the development of power semiconductor devices for automotive applications Diameter dependence of scattering limited transport properties of Si nanowire MOSFETs under uniaxial tensile strain Novel biosensing devices for medical applications Soft contact-lens sensors for monitoring tear sugar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1