Relative Biological Effectiveness Studies Using 3 MeV Proton Beam from Folded Tandem Ion Accelerator: An Experimental and Theoretical Approach

Rajesha K. Nairy, N. Bhat, K. Anjaria, U. Yadav, R. Chaurasia, K. Shirsath, Utkarsha N. Desai, Sanjay Gupta, B. K. Sapra, Narayana Yerol
{"title":"Relative Biological Effectiveness Studies Using 3 MeV Proton Beam from Folded Tandem Ion Accelerator: An Experimental and Theoretical Approach","authors":"Rajesha K. Nairy, N. Bhat, K. Anjaria, U. Yadav, R. Chaurasia, K. Shirsath, Utkarsha N. Desai, Sanjay Gupta, B. K. Sapra, Narayana Yerol","doi":"10.5772/intechopen.94243","DOIUrl":null,"url":null,"abstract":"Proton being the easiest light ion to accelerate and achieve desired beam profile, has been pursued as a popular particulate radiation for therapy applications. In the present study, Saccharomyces cerevisiae D7 strain was used to estimate the RBE values of the 3 MeV proton beam, and an attempt was made to derive mathematical formula for calculating RBE value with respect to the dose. Dosimetry studies were carried out using Fricke dosimetry and Semiconductor Surface Barrier detector to calibrate the absorbed doses of Gamma chamber-1200 and Folded Tandem Ion Accelerator respectively. Gold standard cell survival assay and gene conversion assay were used to compare gamma and proton radiation induced cell death and genetic endpoint. Multi target single hit model was used to derive mathematical formula for RBE estimation. The results show a linear survival-dose response after proton radiation and sigmoid survival-dose response after gamma radiation treatment. The calculated RBE value from the survival and gene conversion studies was 1.60 and 3.93, respectively. The derived mathematical formula is very useful in calculating RBE value, which varies from 3.61 to 1.80 with increasing dose. The estimated RBE value from the mathematical formula is comparable with the experimental values. With the help of the present mathematical formulation, RBE value at any dose can be calculated in the exponential and sigmoidal regions of the survival curve without actually extending the experiment in that dose region, which is not possible using conventional methods.","PeriodicalId":250970,"journal":{"name":"Recent Techniques and Applications in Ionizing Radiation Research","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Recent Techniques and Applications in Ionizing Radiation Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5772/intechopen.94243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Proton being the easiest light ion to accelerate and achieve desired beam profile, has been pursued as a popular particulate radiation for therapy applications. In the present study, Saccharomyces cerevisiae D7 strain was used to estimate the RBE values of the 3 MeV proton beam, and an attempt was made to derive mathematical formula for calculating RBE value with respect to the dose. Dosimetry studies were carried out using Fricke dosimetry and Semiconductor Surface Barrier detector to calibrate the absorbed doses of Gamma chamber-1200 and Folded Tandem Ion Accelerator respectively. Gold standard cell survival assay and gene conversion assay were used to compare gamma and proton radiation induced cell death and genetic endpoint. Multi target single hit model was used to derive mathematical formula for RBE estimation. The results show a linear survival-dose response after proton radiation and sigmoid survival-dose response after gamma radiation treatment. The calculated RBE value from the survival and gene conversion studies was 1.60 and 3.93, respectively. The derived mathematical formula is very useful in calculating RBE value, which varies from 3.61 to 1.80 with increasing dose. The estimated RBE value from the mathematical formula is comparable with the experimental values. With the help of the present mathematical formulation, RBE value at any dose can be calculated in the exponential and sigmoidal regions of the survival curve without actually extending the experiment in that dose region, which is not possible using conventional methods.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
折叠串联离子加速器3mev质子束的相对生物效应研究:实验和理论方法
质子是最容易加速和达到理想光束轮廓的光离子,已成为一种流行的粒子辐射治疗应用。本研究以酿酒酵母D7菌株估算了3mev质子束的RBE值,并尝试推导出计算RBE值与剂量关系的数学公式。采用Fricke剂量计和半导体表面势垒探测器分别对γ室-1200和折叠串联离子加速器的吸收剂量进行了标定。采用金标准细胞存活法和基因转换法比较γ和质子辐射诱导的细胞死亡和遗传终点。采用多目标单命中模型,推导出RBE估计的数学公式。结果显示质子辐射后的生存剂量呈线性反应,伽玛辐射治疗后的生存剂量呈s型反应。生存和基因转化研究计算的RBE值分别为1.60和3.93。推导出的数学公式对计算RBE值非常有用,随剂量的增加RBE值在3.61 ~ 1.80之间变化。由数学公式估计的RBE值与实验值具有可比性。在此数学公式的帮助下,任何剂量下的RBE值都可以在生存曲线的指数区和s型区计算,而无需在该剂量区实际延长实验时间,这是传统方法无法做到的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Relative Biological Effectiveness Studies Using 3 MeV Proton Beam from Folded Tandem Ion Accelerator: An Experimental and Theoretical Approach Biologically Effective Dose (BED) or Radiation Biological Effect (RBEf)? Production of the 103Pd via Cyclotron and Preparation of the Brachytherapy Seed Influence of the Doping Ion Nature and Content on Defect Creation Processes under the Effect of Ionizing Radiation in Aluminoborosilicate Glasses Natural Radioactive Decay
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1