{"title":"TENSILE STRENGTH AND VIOLENT CONNECTION LAS STEEL ST 40 WITH EMPLOYING VARIATIONS ELECTROTECHNICS AND VARIATIONS OF CURRENT","authors":"Masri Bin Ardin","doi":"10.30870/vanos.v3i2.4116","DOIUrl":null,"url":null,"abstract":"Shield Metal arc welding (SMAW) is one of ways which are usually used for welding steel low carbon. The quality of the welding connection can be grouped by using pull testing, and Vickers method. This study aims to know the strength of pulling and hardness welding connection with the variation of electrodes and current. This study used carbon steel ST 40 with an electrode which is used E 6010 and E 7016 with the current variations 80 ampere, 90 ampere and 100 ampere. The result produced the result to the power of certainly drag out from a current of 80 a use electrodes 6010 was recorded at 34,92 kg / mm2. Of tensile strength with a current of 90 a shall be 37.43 kg / mm2 and tensile strength the use of a 100 a shall be 40,63. The force of attraction to the electrode 7016 is promoting the creation of ampere 80 is 33,11 kg / mm2, ampere 90 of tensile strength him it is the same 35,57 kg / mm2 while using ampere 100 of tensile strength that is produced is 37,76 kg / mm2. The difference between the value of the force of attraction for a current is 80 a 1,81 kg / mm2. A current of 90 a 1,86 kg / mm2 and with a current of 100 a 2,87 kg / mm2 for the material structure image on the fault of drag monitoring shows the material is ductile because the fault looks low and high.","PeriodicalId":389382,"journal":{"name":"Vanos: Journal of Mechanical Engineering Education","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vanos: Journal of Mechanical Engineering Education","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30870/vanos.v3i2.4116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Shield Metal arc welding (SMAW) is one of ways which are usually used for welding steel low carbon. The quality of the welding connection can be grouped by using pull testing, and Vickers method. This study aims to know the strength of pulling and hardness welding connection with the variation of electrodes and current. This study used carbon steel ST 40 with an electrode which is used E 6010 and E 7016 with the current variations 80 ampere, 90 ampere and 100 ampere. The result produced the result to the power of certainly drag out from a current of 80 a use electrodes 6010 was recorded at 34,92 kg / mm2. Of tensile strength with a current of 90 a shall be 37.43 kg / mm2 and tensile strength the use of a 100 a shall be 40,63. The force of attraction to the electrode 7016 is promoting the creation of ampere 80 is 33,11 kg / mm2, ampere 90 of tensile strength him it is the same 35,57 kg / mm2 while using ampere 100 of tensile strength that is produced is 37,76 kg / mm2. The difference between the value of the force of attraction for a current is 80 a 1,81 kg / mm2. A current of 90 a 1,86 kg / mm2 and with a current of 100 a 2,87 kg / mm2 for the material structure image on the fault of drag monitoring shows the material is ductile because the fault looks low and high.
保护金属电弧焊是焊接低碳钢的常用方法之一。焊接接头的质量可以通过拉拔试验和维氏法进行分组。本研究旨在了解焊接接头的拉拔强度和硬度随电极和电流的变化情况。本研究使用碳钢st40,电极采用e6010和e7016,电流变化为80安培,90安培和100安培。结果产生的结果,当然拖出的功率从电流80 a使用电极6010记录为34,92 kg / mm2。电流为90a时的抗拉强度为37.43 kg / mm2,使用100a时的抗拉强度为40,63。对电极7016的吸引力促进了安培80的产生是33,11 kg / mm2,安培90的抗拉强度是35,57 kg / mm2,而使用安培100的抗拉强度是37,76 kg / mm2。电流的引力值之间的差是80和1,81 kg / mm2。电流为90 A 1.86 kg / mm2和电流为100 A 2.87 kg / mm2的材料结构图像上的故障拖动监测显示材料是延展性的,因为故障看起来低和高。