Ting-Wei Chang, Hung-Chih Chiang, Chir-Weei Chang, Chy-Lin Wang, Yuan-Chin Lee
{"title":"FF OCT with a swept source integrating a SLD and an AOTF","authors":"Ting-Wei Chang, Hung-Chih Chiang, Chir-Weei Chang, Chy-Lin Wang, Yuan-Chin Lee","doi":"10.1109/ICIIBMS.2017.8279689","DOIUrl":null,"url":null,"abstract":"A full-field optical coherence tomography with a swept source integrating a superluminescent diode and an acousto-optic tunable filter is designed, implemented, and tested. The center wavelength and the bandwidth of the swept source are 840nm and 50nm, respectively. There are estimated about 688 laser lines generated in a sweep cycle. For convenience, a Mirau objective lens is adopted to simplify the system structure. Some preliminary experiments were conducted by using the system, and an onion was adopted as the sample. Two clear restored 3D images of the onion were obtained by using two different algorithms. The differences between the two images were also compared with each other. Further improvement and experiments by using this system are still in progress.","PeriodicalId":122969,"journal":{"name":"2017 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIBMS.2017.8279689","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A full-field optical coherence tomography with a swept source integrating a superluminescent diode and an acousto-optic tunable filter is designed, implemented, and tested. The center wavelength and the bandwidth of the swept source are 840nm and 50nm, respectively. There are estimated about 688 laser lines generated in a sweep cycle. For convenience, a Mirau objective lens is adopted to simplify the system structure. Some preliminary experiments were conducted by using the system, and an onion was adopted as the sample. Two clear restored 3D images of the onion were obtained by using two different algorithms. The differences between the two images were also compared with each other. Further improvement and experiments by using this system are still in progress.