M. Kuroiwa, Y. Shimamoto, Y. Yasuda, S. Wakamoto, M. Nakazawa
{"title":"Hysteresis characteristics vs relative humidity for AT-Cut quartz humidity sensors","authors":"M. Kuroiwa, Y. Shimamoto, Y. Yasuda, S. Wakamoto, M. Nakazawa","doi":"10.1109/FREQ.2001.956283","DOIUrl":null,"url":null,"abstract":"This paper describes experiments regarding the hysteresis of relative humidity on AT-cut quartz humidity sensors. This research was conducted to investigate principally the mechanism with respect to frequency change, etc. (including the impedance changes and equivalent circuit constant fluctuations) for the above humidity sensors.","PeriodicalId":369101,"journal":{"name":"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FREQ.2001.956283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This paper describes experiments regarding the hysteresis of relative humidity on AT-cut quartz humidity sensors. This research was conducted to investigate principally the mechanism with respect to frequency change, etc. (including the impedance changes and equivalent circuit constant fluctuations) for the above humidity sensors.