{"title":"Temperature sensors based on GaPO/sub 4/","authors":"P. Krempl, C. Reiter, W. Wallnofer, J. Neubig","doi":"10.1109/ULTSYM.2002.1193552","DOIUrl":null,"url":null,"abstract":"Results of investigations of temperature sensors using singly rotated Gallium Orthophosphate (GaPO/sub 4/) Y-cut resonators are presented in this paper. Depending on rotating angle the most important parameters - sensitivity, resolution and linearity differ in a wide range. Theoretical calculations leads to cuts owning nearly a linear response with sensitivity between 44.5 ppm//spl deg/C and 46.5 ppm//spl deg/C within a temperature range from room temperature to 600/spl deg/C with a high resolution of about 10/sup -6//spl deg/C. First measurements confirm the theoretically predicted sensitivity. The broad thermal stability range of GaPO/sub 4/ can also be used for temperature sensors based on surface acoustic wave devices. By theoretical calculations, suitable orientations with high temperature coefficients are identified.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1193552","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
Results of investigations of temperature sensors using singly rotated Gallium Orthophosphate (GaPO/sub 4/) Y-cut resonators are presented in this paper. Depending on rotating angle the most important parameters - sensitivity, resolution and linearity differ in a wide range. Theoretical calculations leads to cuts owning nearly a linear response with sensitivity between 44.5 ppm//spl deg/C and 46.5 ppm//spl deg/C within a temperature range from room temperature to 600/spl deg/C with a high resolution of about 10/sup -6//spl deg/C. First measurements confirm the theoretically predicted sensitivity. The broad thermal stability range of GaPO/sub 4/ can also be used for temperature sensors based on surface acoustic wave devices. By theoretical calculations, suitable orientations with high temperature coefficients are identified.