Non-cylindrical transmission focusing for large depth of field

S. Umemura, T. Azuma, Y. Miwa, K. Sasaki, T. Sugiyama, T. Hayashi, H. Kuribara
{"title":"Non-cylindrical transmission focusing for large depth of field","authors":"S. Umemura, T. Azuma, Y. Miwa, K. Sasaki, T. Sugiyama, T. Hayashi, H. Kuribara","doi":"10.1109/ULTSYM.2002.1192629","DOIUrl":null,"url":null,"abstract":"In imaging with a microbubble contrast agent, which tends to make irreversible changes by transmission even at a low intensity, both transmission beamwidth and number of transmission per frame must be minimized. A transmission focusing technique based on a noncylindrical delay, which is applicable to a one-dimensional array, is proposed. Unlike X waves, the main beam propagates always coherently with the waves transmitted from the central part of the aperture. The non-cylindrical focusing delay was calculated by assuming a local focal length along the aperture, which increases gradually as the distance from the center increases. Numerical simulation of wave propagation predicted a large depth of field for a reasonably narrow main beam having longitudinally uniform intensity. The noncylindrical focusing was employed in a prototype beamformer, and the large depth of transmission field was confirmed with Shrielen measurements.","PeriodicalId":378705,"journal":{"name":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","volume":"270 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Ultrasonics Symposium, 2002. Proceedings.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2002.1192629","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

In imaging with a microbubble contrast agent, which tends to make irreversible changes by transmission even at a low intensity, both transmission beamwidth and number of transmission per frame must be minimized. A transmission focusing technique based on a noncylindrical delay, which is applicable to a one-dimensional array, is proposed. Unlike X waves, the main beam propagates always coherently with the waves transmitted from the central part of the aperture. The non-cylindrical focusing delay was calculated by assuming a local focal length along the aperture, which increases gradually as the distance from the center increases. Numerical simulation of wave propagation predicted a large depth of field for a reasonably narrow main beam having longitudinally uniform intensity. The noncylindrical focusing was employed in a prototype beamformer, and the large depth of transmission field was confirmed with Shrielen measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非圆柱形传输聚焦大景深
在使用微泡造影剂成像时,即使在低强度下也容易通过传输产生不可逆的变化,因此必须最小化传输波束宽度和每帧传输的数量。提出了一种适用于一维阵列的基于非圆柱延迟的传输聚焦技术。与X波不同的是,主波束总是与从光圈中心传播的波一致传播。非圆柱形聚焦延迟的计算方法是沿光圈假定一个局部焦距,该焦距随距中心距离的增加而逐渐增大。波传播的数值模拟预测了具有纵向均匀强度的相当窄的主波束的大景深。在原型波束形成器中采用了非圆柱形聚焦,并通过Shrielen测量证实了大透射场深度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of transducers arrays from piezoelectric hollow spheres Non-cylindrical transmission focusing for large depth of field Detection and mapping of thermal lesions using dual-mode ultrasound phased arrays Layered manufacturing for prototyping of novel transducers The effect of microbubble concentration on thresholds for tissue damage produced by single bursts of high intensity ultrasound during continuous Optison/spl reg/ infusion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1