Towards an Impedance-Based Criterion for Efficient Analysis of Resonant Overvoltages in the Swedish Transmission System

O. Lennerhag, Gustav Sundberg, Robert Rogersten, Stefan Råström
{"title":"Towards an Impedance-Based Criterion for Efficient Analysis of Resonant Overvoltages in the Swedish Transmission System","authors":"O. Lennerhag, Gustav Sundberg, Robert Rogersten, Stefan Råström","doi":"10.1109/ICHQP53011.2022.9808573","DOIUrl":null,"url":null,"abstract":"Time domain simulations can be used to study complex problems such as resonant overvoltages following transformer saturation. However, it is often too time consuming to use time domain tools to assess the risk. Therefore, this work develops an impedance-based criterion for efficient analysis of resonant overvoltages in the Swedish transmission system. To develop the impedance-based criterion, two study cases are considered: a heavily cablified urban network, and future connection of offshore wind in a weaker part of the network. The overvoltage stress is evaluated considering thermal and dielectric sensitivities of the various components. The selected impedance limits were found to be in line with those used by other transmission network operators.","PeriodicalId":249133,"journal":{"name":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 20th International Conference on Harmonics & Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP53011.2022.9808573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Time domain simulations can be used to study complex problems such as resonant overvoltages following transformer saturation. However, it is often too time consuming to use time domain tools to assess the risk. Therefore, this work develops an impedance-based criterion for efficient analysis of resonant overvoltages in the Swedish transmission system. To develop the impedance-based criterion, two study cases are considered: a heavily cablified urban network, and future connection of offshore wind in a weaker part of the network. The overvoltage stress is evaluated considering thermal and dielectric sensitivities of the various components. The selected impedance limits were found to be in line with those used by other transmission network operators.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于阻抗的瑞典输电系统谐振过电压有效分析准则研究
时域仿真可以用于研究变压器饱和后的谐振过电压等复杂问题。然而,使用时域工具来评估风险通常太耗时了。因此,这项工作开发了一个基于阻抗的标准,用于有效分析瑞典输电系统中的谐振过电压。为了开发基于阻抗的准则,考虑了两个研究案例:一个是高度布线的城市网络,以及未来在网络较弱部分连接海上风电。过电压应力的评估考虑了各种元件的热灵敏度和介电灵敏度。所选择的阻抗限制与其他传输网络运营商使用的阻抗限制一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Voltage-Current Ratio Difference Method: Recommended for IEEE Standard 1547 to Determine the Customer Harmonic Contribution Operation of a Distributed Generation Plant in a Power Supply System with Non-linear and Asymmetric Load Trend analysis for power quality parameters based on long-term measurement campaigns Power Quality Data Platform for Analysis and Location of Voltage Dips: a Preliminary Study Classification of Scalogram Signatures for Power Quality Disturbances Using Transfer Learning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1