{"title":"SOS: isolated health monitoring system to save our satellites","authors":"S. Narayana, R. V. Prasad, T. V. Prabhakar","doi":"10.1145/3458864.3466862","DOIUrl":null,"url":null,"abstract":"With the advent of Space-IoTs, the rate of launch of satellites has grown significantly. Alongside, the failure rate of satellites has also surged increased tremendously. Satellites are non-repairable systems in orbit, and the financial loss incurred when the satellites fail before their expected mission time is substantial. If the source of a failure is known while the satellite is in orbit, then there is a possibility to revive it by sending appropriate commands from ground stations. In this work, we present a simple, independent satellite health monitoring system called Chirper. The Chirper is equipped with multiple modules such as IMU, isolated voltage and current measurement probes, and an onboard communication channel. We present a new approach to measure low DC voltages in an isolated way, providing a resolution and accuracy of around 1 V. We evaluated the design and performance of the Chirper through simulation, testing it in space systems test facility, and by mounting it on a helium balloon. With extensive experiments we show that 90% of the time the dc voltage measurement error is within 0.8 V, and the maximum error is 0.9 V. We expect to launch the Chirper soon on a space system.","PeriodicalId":153361,"journal":{"name":"Proceedings of the 19th Annual International Conference on Mobile Systems, Applications, and Services","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 19th Annual International Conference on Mobile Systems, Applications, and Services","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3458864.3466862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
With the advent of Space-IoTs, the rate of launch of satellites has grown significantly. Alongside, the failure rate of satellites has also surged increased tremendously. Satellites are non-repairable systems in orbit, and the financial loss incurred when the satellites fail before their expected mission time is substantial. If the source of a failure is known while the satellite is in orbit, then there is a possibility to revive it by sending appropriate commands from ground stations. In this work, we present a simple, independent satellite health monitoring system called Chirper. The Chirper is equipped with multiple modules such as IMU, isolated voltage and current measurement probes, and an onboard communication channel. We present a new approach to measure low DC voltages in an isolated way, providing a resolution and accuracy of around 1 V. We evaluated the design and performance of the Chirper through simulation, testing it in space systems test facility, and by mounting it on a helium balloon. With extensive experiments we show that 90% of the time the dc voltage measurement error is within 0.8 V, and the maximum error is 0.9 V. We expect to launch the Chirper soon on a space system.