Analisis Efisiensi Generator Pada GT21 Blok 2 Pembangkit Listrik Tenaga Gas Dan Uap PT. CEPA Sengkang

Ashar Ar, H. Hamma, Wisna Saputri Alfira WS, Andarini Asri, A. Ardiyansyah
{"title":"Analisis Efisiensi Generator Pada GT21 Blok 2 Pembangkit Listrik Tenaga Gas Dan Uap PT. CEPA Sengkang","authors":"Ashar Ar, H. Hamma, Wisna Saputri Alfira WS, Andarini Asri, A. Ardiyansyah","doi":"10.31963/elekterika.v6i2.3805","DOIUrl":null,"url":null,"abstract":"       PLTGU Sengkang which is operated by PT. CEPA Sengkang with a total capacity of 315 MW. One of the important components in the PLTGU system is a generator. In a generator there are many problems that arise, including generator efficiency problems. The research that will be carried out is to determine the generator efficiency value and then determine how much the generator efficiency value increases. In finding the efficiency value by making daily and monthly loading curves using generator output power, generator input power data, generator nameplate and generator power losses at 25%, 50%, 75%, and 100% loading. In this study, taking a sample that lasted for 1 month (31 days) of generator efficiency data for each loading and comparing the actual with the generator specifications, the difference for loading 25% experienced a decrease in efficiency of 0.35%, for loading 50% experienced an efficiency increase of 0.12%, for loading 75% increased efficiency of 0.25% and for loading 100% increased efficiency of 0.32%. In this study the generator has experienced reverse power so that the efficiency of the generator has decreased. The average efficiency in May 2022 was 96.21%, with an average load of 29.96 MW and an average input power of 31.14 MW. Referring to the manual book Block 2 PLTGU PT. CEPA Sengkang is known that the generator efficiency value is by design divided into 4 loadings. For loading 25% efficiency is 96.6%, for loading 50% efficiency is 98.45%, for loading 75% efficiency is 98.82%, and for loading 100% efficiency is 98.93% and so that the optimum efficiency of the generator occurs at a load of 54.2 MW (loading 100 %) with a value of 99.62%.","PeriodicalId":316017,"journal":{"name":"Jurnal Teknologi Elekterika","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknologi Elekterika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31963/elekterika.v6i2.3805","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

       PLTGU Sengkang which is operated by PT. CEPA Sengkang with a total capacity of 315 MW. One of the important components in the PLTGU system is a generator. In a generator there are many problems that arise, including generator efficiency problems. The research that will be carried out is to determine the generator efficiency value and then determine how much the generator efficiency value increases. In finding the efficiency value by making daily and monthly loading curves using generator output power, generator input power data, generator nameplate and generator power losses at 25%, 50%, 75%, and 100% loading. In this study, taking a sample that lasted for 1 month (31 days) of generator efficiency data for each loading and comparing the actual with the generator specifications, the difference for loading 25% experienced a decrease in efficiency of 0.35%, for loading 50% experienced an efficiency increase of 0.12%, for loading 75% increased efficiency of 0.25% and for loading 100% increased efficiency of 0.32%. In this study the generator has experienced reverse power so that the efficiency of the generator has decreased. The average efficiency in May 2022 was 96.21%, with an average load of 29.96 MW and an average input power of 31.14 MW. Referring to the manual book Block 2 PLTGU PT. CEPA Sengkang is known that the generator efficiency value is by design divided into 4 loadings. For loading 25% efficiency is 96.6%, for loading 50% efficiency is 98.45%, for loading 75% efficiency is 98.82%, and for loading 100% efficiency is 98.93% and so that the optimum efficiency of the generator occurs at a load of 54.2 MW (loading 100 %) with a value of 99.62%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
这是对PT. CEPA Sengkang发电厂g21号街区的发电机效率分析
PLTGU Sengkang由PT. CEPA Sengkang运营,总容量为315兆瓦。PLTGU系统的重要组成部分之一是发电机。在发电机中会出现许多问题,包括发电机效率问题。将要进行的研究是确定发电机效率值,然后确定发电机效率值增加多少。利用发电机输出功率、发电机输入功率数据、发电机铭牌和25%、50%、75%、100%负荷时的发电机功率损耗,绘制日、月负荷曲线,求效率值。在本研究中,选取了每次加载1个月(31天)的发电机效率数据样本,并将实际与发电机规格进行比较,加载25%时效率下降0.35%,加载50%时效率提高0.12%,加载75%时效率提高0.25%,加载100%时效率提高0.32%。在本研究中,发电机经历了反向功率,使发电机的效率下降。2022年5月平均效率为96.21%,平均负荷为29.96 MW,平均输入功率为31.14 MW。参考手册Block 2 PLTGU PT. CEPA Sengkang了解到,发电机效率值按设计分为4个负荷。加载25%效率为96.6%,加载50%效率为98.45%,加载75%效率为98.82%,加载100%效率为98.93%,因此发电机的最佳效率出现在负载为54.2 MW(加载100%)时,其值为99.62%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Perancangan Sistem Human Machine Interface (HMI) untuk Monitoring Daya Sinkronisasi Paralel Genset Sistem Kendali Hidrogen Pada HCl Burner Menggunakan Controller Yokogawa Pengujian Long-Short Term Memory (LSTM) Pada Prediksi Trafik Lalu Lintas Menggunakan Multi Server Analisis Efisiensi Generator Pada GT21 Blok 2 Pembangkit Listrik Tenaga Gas Dan Uap PT. CEPA Sengkang Analasis Penerapan Teknologi Traffic Steering SD-WAN Menggunakan Perangkat FortiGate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1