{"title":"Active Power Estimation in the Non-coherent Sampling: A Comparative Study","authors":"D. Agrez","doi":"10.1109/IMTC.2005.1604212","DOIUrl":null,"url":null,"abstract":"The paper presents and compares three basic approaches of the active power estimation of electrical systems under noncoherent sampling conditions when the leakage effect arises. The properties of the normal time domain approach with smoothing and summation and two frequency domain approaches with improved interpolated DFT estimations of the parameters are studied with respect to their systematic errors and effectiveness in leakage suppression. The simulations are presented showing advantages and weaknesses of compared methods in the shortening measurement time: between one and six cycles in the measurement interval. From analysis and experiments, it can be deduced that averaging of DFT coefficients around zero component provides the best estimation of the active power when the DC offset component is small enough","PeriodicalId":244878,"journal":{"name":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE Instrumentationand Measurement Technology Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.2005.1604212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The paper presents and compares three basic approaches of the active power estimation of electrical systems under noncoherent sampling conditions when the leakage effect arises. The properties of the normal time domain approach with smoothing and summation and two frequency domain approaches with improved interpolated DFT estimations of the parameters are studied with respect to their systematic errors and effectiveness in leakage suppression. The simulations are presented showing advantages and weaknesses of compared methods in the shortening measurement time: between one and six cycles in the measurement interval. From analysis and experiments, it can be deduced that averaging of DFT coefficients around zero component provides the best estimation of the active power when the DC offset component is small enough
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
非相干采样中有功功率估计的比较研究
本文介绍并比较了在非相干采样条件下产生泄漏效应时电力系统有功功率估计的三种基本方法。研究了采用平滑求和法的正常时域方法和采用改进内插DFT估计参数的两种频域方法的系统误差和泄漏抑制效果。仿真结果显示了比较方法在缩短测量时间方面的优缺点:测量周期在1 ~ 6个周期之间。通过分析和实验可以得出,当直流偏置分量足够小时,对零分量附近的DFT系数进行平均可以得到最佳的有功功率估计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Low-Cost Real-Time Virtual Spectrum Analyzer Determination of thickness and dielectric constant of coatings from capacitance measurements Noninvasive Measurement of Blood Glucose Based on Optical Sensing and Internal Standard Method A Technique for Image Denoising Based on Adaptive Piecewise Linear Filters and Automatic Parameter Tuning Error Recovery Service for the IEEE 802.11B Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1